𝑎𝑓𝑡 𝑁𝑡 0.

515𝑖𝑛2 252
𝑎𝑓𝑡 = ( ) =( ) = 0.15𝑓𝑡 2
𝑡𝑢𝑏𝑜 #𝑝𝑎𝑠𝑜𝑠 𝑓𝑡 2 6
144 2
𝑖𝑛
𝑙𝑏
𝑊𝑝𝑒𝑡𝑟𝑜𝑙𝑒𝑜 149000 ℎ 𝑙𝑏
𝐺𝑡 = = = 993333 2
𝑎𝑓𝑡 0.15𝑓𝑡 2 𝑓𝑡 ℎ

ℎ𝑖𝑜 𝑑𝑖 𝐶𝑝𝜇 1/3 𝑑𝑖 𝑣𝑖 𝜌 0.8 𝑑𝑖


= 0.027 ( ) ( ) (𝜑𝑖) ( )
𝑘 𝑘 𝜇 𝑑𝑜
1/3
𝐵𝑇𝑈
𝐶𝑝𝜇 1/3 (0.43

)(2.5𝑐𝑝)(2.42)
( ) =( ) = 3.26
𝑘 0.075

0.8
0.810𝑖𝑛 𝑙𝑏
𝑑𝑖 𝑣𝑖 𝜌 0.8 ( ) (993333 2 )
12𝑓𝑡/𝑖𝑛 𝑓𝑡 ℎ
( ) =( ) = 1720
𝜇 (2.5𝑐𝑝)(2.42)

𝑑𝑖 0.810𝑖𝑛
( )=( ) = 0.81
𝑑𝑜 1𝑖𝑛

ℎ𝑖𝑜 0.075 𝐵𝑇𝑈


= 0.027(3.26)(1720)(0.81) ( ) = 137
𝜑𝑖 0.81𝑖𝑛 ℎ𝑓𝑡 2 °𝐹
( )
12𝑓𝑡/𝑖𝑛

A la temperatura de la pared 340°F petroleo= 0.55cp

𝜇 0.14 2.5𝑐𝑝 0.14


𝜑𝑖 = ( ) =( ) = 1.24
𝜇𝑤 0.55𝑐𝑝

Despejando hio
𝐵𝑇𝑈 𝐵𝑇𝑈
ℎ𝑖𝑜 = (137 ) (1.24) = 169
ℎ𝑓𝑡 2 °𝐹 ℎ𝑓𝑡 2 °𝐹