Professional Documents
Culture Documents
Big-Ip Virtual Edition and Vmware Esxi: Setup
Big-Ip Virtual Edition and Vmware Esxi: Setup
Setup
Version 12.0
Table of Contents
Table of Contents
Legal Notices............................................................................................................................ 17
Legal notices.................................................................................................................... 17
3
Table of Contents
4
Getting Started with BIG-IP Virtual Edition on ESXi
Step Details
1 Choose the license you want to buy, the BIG-IP VE modules you want, and the throughput
you need. See SOL14810: Overview of BIG-IP® VE license and throughput limits on the
AskF5™ Knowledge Base (http://support.f5.com) for details.
2 Confirm that you are running a hypervisor version that is compatible with a BIG-IP VE
release. See Virtual Edition and Supported Hypervisors Matrix on http://
support.f5.com for details.
After you complete these tasks, you can log in to the BIG-IP VE system and run the Setup utility to
perform basic network configuration.
Getting Started with BIG-IP Virtual Edition on ESXi
6
Prerequisites for BIG-IP Virtual Edition on ESXi
6. Use either the console command line or user interface to configure the VLANs that will serve as pass-
through devices for the virtual function. For each interface and VLAN combination, specify a name
and a value.
• Name - pciPassthru0.defaultVlan
• Value - 3001
To complete SR-IOV configuration, after you deploy BIG-IP® VE, you must add three PCI device NICs
and map them to your networks.
Important: To achieve licensing performance limits, all allocated memory must be reserved.
8
BIG-IP Virtual Edition and VMware ESXi: Setup
For production environments, virtual disks should be deployed Thick (allocated up front). Thin
deployments are acceptable for lab environments.
Note: To change the disk size after deploying the BIG-IP system, see Increase the disk space allotted to
the BIG-IP® virtual machine.
9
Prerequisites for BIG-IP Virtual Edition on ESXi
10
Deploying BIG-IP Virtual Edition in ESXi
Section Details
Configuration Choose from the available configurations. You
can change CPU or RAM later.
Storage If you decide to increase storage later, you must
also adjust the BIG-IP directories to use the extra
storage space. See Increase the disk space
allotted to the BIG-IP® virtual machine for
details.
Datastore Choose Thick for production environments.
Thin is sufficient for lab environments.
Source Networks The wizard leads you through creating four
networks: internal, external, management, and
high availability (HA).
Ready to Complete Select the Power on after deployment check
box.
11. Click Finish.
The virtual machine is created, as well as two user accounts.
• The root account provides access locally, using SSH, or the F5 Configuration utility. The root account
password is default.
• The admin account provides access through the web interface. The admin account password is
admin.
You should change passwords for both accounts before bringing a system into production.
If you need to create a redundant configuration, place the two BIG-IP VE virtual appliances (the active-
standby pair) on separate physical hosts. You can accomplish this in one of two ways:
• Manually create a virtual machine peer on each host.
Deploying BIG-IP Virtual Edition in ESXi
• If you are using VMware Dynamic Resource Scheduler (DRS), create a DRS rule with the Separate
Virtual Machine option that includes each BIG-IP VE in the pair.
Important: Do not use VMware tools to configure the IP address; the BIG-IP system will not use these
changes.
2. Edit the settings for the virtual machine to add a PCI device.
If your hypervisor was set up correctly, there will be 16 virtual functions on each port (05:10.x and
05:11:x).
3. Map the new device to the VLAN for your internal subnet.
4. Repeat steps 2 and 3 for the external and HA VLANs.
5. When all four destination networks are correctly mapped, click Next.
The Ready to Complete screen opens.
12
After Deploying BIG-IP VE on ESXi
Note: You must have the admin user role to enable or disable TSO support.
5. Confirm that LRO and GRO are turned off by running this command: ethtool -k eth<X>.
In the system response to your command, you should see this info:
generic-receive-offload: off
large-receive-offload: off
If either of these responses is on, your attempt to turn them off was not successful.
6. Repeat this process for each of the NICs that the BIG-IP VE uses to pass traffic.
See the ESXi documentation for more details.
Note: At the time of this release, decreasing the VE disk size is not supported.
14
Updating BIG-IP VE
You do not need to reinstall BIG-IP® VE in order to install updates. You can use the Software
Management tool in the Configuration utility, or you can upgrade the software from the command line.
To update BIG-IP VE, you will:
1. Download the ISO and MD5 files.
2. Install the downloaded files to an inactive boot location.
3. Boot the BIG-IP VE to the new boot location.
Important: Before you perform the installation, you should test the integrity of the ISO files to verify
that you have downloaded clean copies. Use an MD5 verification program to ensure that the
downloaded ISO files' checksums match the values in their corresponding MD5 files.
4. In the BIG-IP VE user interface, on the Main tab, click System > Software Management > Image
List > Import.
5. Click Browse to navigate to the downloaded base level installation file.
6. When the image name appears in the Software Image field, click Import to begin the operation.
Important: Do not navigate away from this screen before the operation is done.
When the import is complete, the Import page closes and the downloaded base image displays as an
available image.
7. Click the Hotfix List tab.
8. At the right side of the screen, click Import.
9. Click Browse to navigate to the downloaded hotfix installation file.
10. When the image name appears in the Software Image field, click Import to begin the operation.
Important: Do not navigate away from this screen before the operation is done.
When the import is complete, the Import page closes and the downloaded hotfix displays in the list of
available images.
You can now install the downloaded update.
Tip: If there is a problem during installation, you can use log messages to troubleshoot a solution.
The system stores the installation log file as /var/log/liveinstall.log.
16
Legal Notices
Legal notices
Publication Date
This document was published on July 29, 2016.
Publication Number
MAN-0347-07
Copyright
Copyright © 2016, F5 Networks, Inc. All rights reserved.
F5 Networks, Inc. (F5) believes the information it furnishes to be accurate and reliable. However, F5
assumes no responsibility for the use of this information, nor any infringement of patents or other rights
of third parties which may result from its use. No license is granted by implication or otherwise under
any patent, copyright, or other intellectual property right of F5 except as specifically described by
applicable user licenses. F5 reserves the right to change specifications at any time without notice.
Trademarks
AAM, Access Policy Manager, Advanced Client Authentication, Advanced Firewall Manager, Advanced
Routing, AFM, APM, Application Acceleration Manager, Application Security Manager, AskF5, ASM,
BIG-IP, BIG-IP EDGE GATEWAY, BIG-IQ, Cloud Extender, Cloud Manager, CloudFucious, Clustered
Multiprocessing, CMP, COHESION, Data Manager, DDoS Frontline, DDoS SWAT, Defense.Net,
defense.net [DESIGN], DevCentral, DevCentral [DESIGN], DNS Express, DSC, DSI, Edge Client, Edge
Gateway, Edge Mobile, Edge Mobility, Edge Portal, ELEVATE, EM, ENGAGE, Enterprise Manager, F5,
F5 [DESIGN], F5 Agility, F5 Certified [DESIGN], F5 Networks, F5 SalesXchange [DESIGN], F5
Synthesis, f5 Synthesis, F5 Synthesis [DESIGN], F5 TechXchange [DESIGN], Fast Application Proxy,
Fast Cache, FCINCO, Global Traffic Manager, GTM, GUARDIAN, iApps, IBR, iCall, iControl, iHealth,
Intelligent Browser Referencing, Intelligent Compression, IPv6 Gateway, iQuery, iRules, iRules
OnDemand, iSession, L7 Rate Shaping, LC, Link Controller, LineRate, LineRate Point, LineRate
Precision, LineRate Systems [DESIGN], Local Traffic Manager, LROS, LTM, Message Security
Manager, MobileSafe, MSM, OneConnect, Packet Velocity, PEM, Policy Enforcement Manager,
Protocol Security Manager, PSM, Ready Defense, Real Traffic Policy Builder, SalesXchange, ScaleN,
SDAS (except in Japan), SDC, Signalling Delivery Controller, Solutions for an application world,
Software Designed Application Services, Silverline, SSL Acceleration, SSL Everywhere, StrongBox,
SuperVIP, SYN Check, SYNTHESIS, TCP Express, TDR, TechXchange, TMOS, TotALL, TDR, TMOS,
Traffic Management Operating System, Traffix, Traffix [DESIGN], Transparent Data Reduction, UNITY,
VAULT, vCMP, VE F5 [DESIGN], Versafe, Versafe [DESIGN], VIPRION, Virtual Clustered
Multiprocessing, WebSafe, and ZoneRunner, are trademarks or service marks of F5 Networks, Inc., in the
U.S. and other countries, and may not be used without F5's express written consent.
All other product and company names herein may be trademarks of their respective owners.
Patents
This product may be protected by one or more patents indicated at: https://f5.com/about-us/policies/
patents
Legal Notices
18
Index
Index
B O
BIG-IP VE on VMware overview 5 OVA file, location 11
BIG-IP Virtual Edition
updating 15
P
C PCI device NIC mapping 12
PEM performance
CPU reservation for ESXi 13 optimizing 13
progress indicator, for update 15
D
R
deployment overview 5
disk size, See virtual disk size reboot operation
downloads after updating 15
and importing update 15
of ISO base file 15
of ISO update file 15
S
SR-IOV
G configuring hypervisor for 7
system update procedure 15
GRO
turning off 13
guest memory 8
T
task list
H for updating on virtual machine 15
TSO support
hypervisor configuring hypervisor for 13
configuring for SR-IOV 7
configuring for TSO 13
U
I update
downloading and importing 15
installation installing 16
rebooting after 15 update progress indicator 15
installation operation 16
ISO file
and location on virtual machine 15
V
downloading 15 virtual disk size
downloading base file 15 extending 14
downloading update file 15 increasing 14
VMware virtual machine 11
L
log file
and location 16
and media speed messages 16
log in
after updating 15
LRO
turning off 13
M
memory
guest 8
19
Index
20