Professional Documents
Culture Documents
3300 5mm Transducer System Datasheet English PDF
3300 5mm Transducer System Datasheet English PDF
Page 1 of 15
Notes:
1. A 5mm probe uses smaller physical packaging and provides the same linear range as a
3300 XL 8mm probe (ref 141194-01). The 5mm probe does not, however, reduce the
sideview clearances or tip-to-tip spacing requirements as compared to an XL 8 mm probe.
IYou should use the 5mm probe when physical (not electrical) constraints preclude the use
of an 8mm probe, such as mounting between thrust bearing pads or other constrained
spaces. When your application requires narrow sideview probes, use the 3300 XL NSv*
probe and extension cable with the 3300 XL NSv Proximitor Sensor (refer to Specifications
and Ordering Information p/n 147385-01).
2. XL 8 mm probes provide a thicker encapsulation of the probe coil in the molded PPS
plastic probe tip to produce a more rugged probe. The larger diameter of the probe body
also provides a stronger, more robust case. We recommend the use of XL 8mm probes
when possible to provide optimal robustness against physical abuse.
3. A 3300 XL Proximitor Sensor is available and provides many improvements over the
non-XL version. The XL sensor is electrically and mechanically interchangeable with the
non-XL version. Although the packaging of the 3300 XL Proximitor Sensor differs from its
predecessor, its design allows you to usea 4-hole mounting base to fit it t in the same 4-
hole mounting pattern and to fit within the same mounting space specifications (when the
application observes the minimum permissible cable bend radius). Consult Specifications
and Ordering Information (p/n 141194-01) or our sales and service professional for more
information.
4. Us of XL components with 3300 5mm Probes will limit system performance to the
specifications for the non-XL 3300 system.
5. The factory supplies Proximitor Sensors that are calibrated by default to AISI 4140 steel.
Calibration to other target materials is available upon request.
6. If you are considering using this transducer system for tachometer or over-speed
measurements, consult www.ge-energy.com/bently for the application note regarding the
use of eddy current proximity probes for over speed protection.
7. We provide silicone tape i with each 3300 XL extension cable. You can use this tape
instead of connector protectors. We do not recommend silicone tape in applications
which will expose the probe-to-extension cable connection to turbine oil.
Page 2 of 15
Table 2: Extension Cable DC Resistance
Specifications
Resistance from Resistance from
Unless otherwise noted, the following specifications Length of
Center Conductor to Outer Conductor to
are for a proximity transducer system between +18 Extension
Center Conductor Outer Conductor
°C and +27 °C (+64 °F to +80 °F) with a -24 Vdc Cable
(RCORE) (Ω) (RJACKET) (Ω)
power supply, a 10 kΩ load, an AISI 4140 steel
target, and a probe gapped at 1.27 mm (50 mils). 3.0 0.66 ± 0.10 0.20 ± 0.04
Page 3 of 15
Incremental at least 50 mm (2 in) or greater.
Scale Factor Care should be taken to maintain
minimum separation of
7.87 V/mm (200 mV/mil) ±6.5%
transducer tips, generally at least
typical, including
40 mm (1.6 in) for axial position
interchangeability error when
measurements or 38 mm (1.5 in)
measured in increments of 0.25
for radial vibration measurements
mm (10 mils) over the linear
to limit cross-talk to 50 mV or less.
range.
Radial vibration or position
Deviation from measurements on shaft
best fit straight diameters smaller than 76.2 mm
line (DSL) (3 in) will generally result in a
change in scale factor. Consult
Less than ±0.038 mm (±1.5 mil)
Performance Specification
typical deviation from best fit
155687 for additional information.
straight line.
Effects of 60 Hz
Probe
Magnetic Fields
Temperature
Up to 300 Gauss
Stability
(typical) See Table 3.
Over probe temperature range of Table 3: Output Voltage in Mil (pk-pk)/Gauss (5-metre
-35 °C to +177 °C (-31 °F to +350 System)
°F), the incremental scale factor
remains within ±10% of 7.87 XL
XL Ext.
V/mm (200 mV/mil) and the Gap Proximitor Probe
Cable
deviation from the best fit straight Sensor
line remains within ±0.076 mm 10 mil 0.0119 0.0004 0.0004
(±3 mils).
50 mil 0.0131 0.0014 0.0014
Frequency
Response 90 mil 0.0133 0.0045 0.0045
Page 4 of 15
Europe
Hazardous Area Approvals 3300 XL
Proximitor
Note: Multiple approvals for hazardous areas certified by
Sensor, ia:
Canadian Standards Association (C/US) in North America
and by Baseefa for Europe and IEC Ex. II 1 G EEx ia IIC T4/T5. EC
certificate number
Table 4: Field Wiring Limitations: BAS99ATEX1101, when installed
L/R
per drawing 141092.
Gas
Type Capacitance Inductance
Grou Ratio 3300 XL
Approval: (µF) (mH)*
p (μH/Ω) Proximitor
Sensor, nA:
ATEX
and IEC IIC 0.078 0.99 29.2 II 3 G Ex nA II T4/T5. EC
Zone 0/1 certificate number Baseefa
IIB 0.645 7.41 117.0 07ATEX0189X, when installed per
IIA 2.144 15.6 234.0 drawing 140979.
CSA Div A
1 and 0.070 1.0 29.2 T5 @ Ta= -35 °C to +85 °C
B
C 0.600 5.0 117.0 T4 @ Ta= -51 °C to +100 °C.
D 2.09 11.0 234.0
CSA Div
All 0.460 100.0 N/A
2
North America
3300 XL
Proximitor
Sensor and 3300 XL 8mm
probe, ia: probe, ia:
Ex ia IIC T4/T5; Class I Zone 0 or II 1 G EEx ia IIC, Temperature
Class 1 Division 1; Groups A, B, C, Classification per table 4-5, EC
and D, when installed with certificate number
intrinsically safe zener barriers BAS99ATEX1099 when installed
per drawing 141092 or when per drawing 142491.
installed with galvanic isolators. 3300 XL 8mm
Certificate number 1109248(LR probe, nA:
26744-222) II 3 G EEx nA II, Temperature
3300 XL Classification per table 4-5, EC
Proximitor certificate number
Sensor and BAS99ATEX3098 when installed
probe, nA: per drawing 142491.
Ex nA IIC T4/T5 Class I Zone 2 or IEC Ex
Class I, Division 2, Groups A, B, C, 3300 XL
and D when installed without Proximitor
barriers per drawing 140979. Sensor, ia
T5 @ Ta = -35 °C to +85 °C. IECEx BAS04.0055X
T4 @ Ta= -51 °C to +100 °C. Ex ia IIC T4 (-51°C ≤ Ta ≤ +100°C) /
Certificate number 1109248(LR T5 (-35ºC ≤ Ta ≤ +85ºC)
26744-222)
Specifications and Ordering Information
Part Number 172036
Rev. G (09/09)
Page 5 of 15
Terminal Block Hazardous Area
Connections Conditions of
Safe Use:
Ui= -28V Ci = 0
Ii= 140mA Li =10µH
ATEX: Follow the conditions of
Pi= 0.84W
safe use included on the
3300 XL Declaration of Conformance sent
Proximitor with each product.
Sensor, nA:
Canadian Standards Association
IECEx BAS04.0057X (CSA):
Ex nA II T4 (-51°C ≤ Ta ≤ +100°C) / Division 1 (Intrinsically
T5 (-35°C ≤ Ta ≤ +85°C) safe): Install per Bently Nevada
drawing 141092.
Ui = -28V
Division 2 (non-Incendive):
3300 XL 8mm
Install per Bently Nevada drawing
and 3300 5mm
140979.
Eddy Current
Probes, ia: IECEx
IECEx BAS04.0056 Zone 0 (Intrinsically safe): The
Proximitor® Sensor must be
Ex ia IIC Temperature
installed to minimize the risk of
Classification per table 5.
impact or friction with other
Ui = -28V Ci = 1.5 nF metallic surfaces.
Li = 140 mA Li = 200 µH
Pi – 0.84 W Zone 2 (non-Incendive): The
probe must be supplied from a
3300 XL 8mm
voltage-limited source.
and 3300 5mm
Eddy Current
Probes, nA
Compliance and Certifications
IECEx BAS04.0058X
EMC:
Ex nA II for Zone 2 Temperature
Classification per table 5. European Community Directives:
EMC Directive 2004/108/EC
Page 6 of 15
Hole Size
Mechanical 0.218 to 0.222 in
Probe Tip Hole Depth
Material 0.376 to 0.750 in
Polyphenylene sulfide (PPS). Tap Size
Probe Case #3
Material
AISI 303 or 304 stainless steel
(SST). Recommended
case hole and
Probe Cable tap size for
75Ω triaxial, fluoroethylene M8x1 case
propylene (FEP) insulated probe Drill Size
cable in the following lengths: 0.5,
1, 2, 5, or 9 metres (1.6, 3.3, 16.4, 7.5mm
or 29.5 feet). Hole Size
System Length 7.625 to 7.72 mm
5 or 9 metres (16.4 or 29.5 feet) Hole Depth
including extension cable.
12 to 24 mm
Extension Cable
Material Tap Size
75 Ω triaxial, fluoroethylene M8x1
propylene (FEP) insulated. Probe case
Probe and torque
Extension Cable 5.1 N·m (45 in·lb) recommended
Armor
7.3 N·m (65 in·lb) maximum
Flexible AISI 302 or 304 SST with
FEP outer jacket Connector-to-
connector
5mm Probe torque
Tensile Strength
Recommended
222 N (50 lbf) probe case to probe torque
lead. 222 N (50 lbf) probe lead to
extension cable connectors. See Table 5.
Connector Table 5: Recommended Torque
material
Connector Type Tightening Instructions
Gold-plated brass or gold-plated
beryllium copper. 2 3300 XL gold "click" type
Finger tight
connectors
Recommended
case hole and 1 non-XL stainless steel
Finger tight plus 1/8 turn
tap size for 1/4- connector and 1 3300 XL
using pliers
28 case connector
Maximum
torque
Drill Size
0.565 N•m (0.42 ft•lbf)
0.213 in
Specifications and Ordering Information
Part Number 172036
Rev. G (09/09)
Page 7 of 15
Minimum Cable Note: It is the responsibility of the customer or user to ensure
Bend Radius that all liquids and gases are contained and safely
controlled should a proximity probe. leak In addition,
25.4 mm (1.0 in).
solutions with high or low pH values may erode the tip
Weight assembly of the probe causing media to leak into
surrounding areas. Bently Nevada LLC will not be held
Total System
responsible for any damages resulting from leaking 3300
0.71 kg (1.6 lbm), typical. 5 mm proximity probes. In addition, Bently Nevda LLC will
not replace 3300 5mm proximity probes under the service
3300 5mm Probe
plan due to probe leakage.
323 g (11.39 oz).
Patents:
XL Extension
Cable One or more components or
procedures described in the
34 g/m (0.4 oz/ft) following patents apply to this
103 g/m (1.5 oz/ft) (armored) product: 5,016,343; 5,126,664;
5,351,388; and 5,685,884.
XL Proximitor
Sensor
246 g (8.7 oz) Ordering Information
Environmental Limits 3300 5 mm Proximity Probes
Probe 330171 3300 5 mm Probe, 1/4-28 UNF thread, without
Temperature armor
Range: 330172 3300 5 mm Probe, 1/4-28 UNF thread, with armor
-35 °C to +177 °C (-31 °F to +351 Part Number-AXX-BXX-CXX-DXX-EXX
°F)
A: Unthreaded Length Option
Note: Exposing the probe to temperatures below –
Note: Unthreaded length must be at least 0.8 in less than the
34 °C (-30 °F) may cause premature failure of the
case length.
pressure seal.
Order in increments of 0.1in
Extension Cable
Length configurations:
Temperature
Maximum unthreaded length:
Range:
8 8 = 8.8 in
-51° C to +177° C (-60° F to +351° Minimum unthreaded length:
F) for standard extension cable. 0 0 = 0.0 in
ref 141194-01 Example: 0 4 = 0.4 in
Page 8 of 15
D: Connector Option Phenolic Probe Mounting Bracket
01 Miniature coaxial ClickLoc
connector with connector The phenolic mounting bracket is recommended if
protector, standard cable additional electric isolation from the mounting
02 Miniature coaxial ClickLoc location is required (as in some generator and
connector, standard cable electrical motor bearing locations). The -02 option is
E: Agency Approval Option supplied with 2 10-24 UNC-2A mounting screws. The
00 Not required -03 option is supplied with 2 M5 x 0.8-6g mounting
05 Multiple Approvals screws. The mounting screws have pre-drilled holes
for safety wire.
3300 5mm Proximity Probes, Metric
27474 -AXX
330173 3300 5 mm Probe, M8 x 1 thread, without armor
A: Thread size
330174 3300 5 mm Probe, M8 x 1 thread, with armor
02 1/4-28
Part Number-AXX-BXX-CXX-DXX-EXX 03 M8 x 1
A: Unthreaded Length Option 75Ω ClickLoc Connector Kit
Note: Unthreaded length must be at least 20 mm less than the 330153-AA
case length.
75Ω ClickLoc Connector Kit for 3300 series probes and
Order in increments of 10 mm. extension cables. Each kit contains 1 color-coded sleeve
Length configuration: per connector.
Max. unthreaded length: 2 3 = 230
A: Kit Type
mm
02 1 ClickLoc male connector for
Min. unthreaded length: 0 0 = 0.0
3300 XL 5mm and 8mm
mm
extension cable.
Example: 0 6 = 60 mm.
03 1 ClickLoc female connector
B: Overall Case Length Option
for 3300 XL 5mm and 8mm
Order in increments of 10 mm.
extension cable.
Metric thread configurations:
04 1 ClickLoc male connector for
Maximum length:
3300 5mm probe.
2 5 = 250 mm
Minimum length:
0 2 = 20 mm
Accessories
Examples: 0 6 = 60 mm. 02120015
C: Total Length Option
05 0.5 metre (1.6 feet) Bulk field wire. 1.0 mm2 (18
10 1.0 metre (3.3 feet) AWG), 3-conductor, twisted,
20 2.0 metres (6.6 feet) shielded cable for connections
50 5.0 metres (16.4 feet) 1 between Proximitor Sensor and
90 9.0 metres (29.5 feet) monitor.
Probe Accessories 03200006
Aluminum probe mounting bracket Silicone self-fusing tape.
The aluminum probe threaded mounting bracket is 9.1-metre (10-yard) roll of silicone
the standard mounting bracket for most 3300 5 mm tape to protect connectors. It is
probe installations. The -02 option is supplied with 2 easy to install and provides
10-24 UNC-2A mounting screws. The -03 option is excellent electrical isolation and
supplied with 2 M5 x 0.8-6g mounting screws. The protection from the environment.
mounting screws have pre-drilled holes for safety It is not recommended for use
wire. inside the casing of the machine.
137492 -AXX
A: Thread size
02 1/4-28
03 M8 x 1
Specifications and Ordering Information
Part Number 172036
Rev. G (09/09)
Page 9 of 15
provide environmental protection
of connectors.
40113-03
03800001
Connector Protector Kit.
Connector Protector Kit for 3300 75Ω Coaxial Female Connector
5mm probes, including connector Protector. Placed onto 3300 5mm
protectors and installation tools. probe leads; attaches to the male
connector protector on the
136536-01
extension cable to provide
Connector Protector Adapter. environmental protection of
Makes connector protector kits connectors.
purchased prior to 1998
163356
compatible with ClickLoc
extension cable connectors. Connector Crimp Tool Kit.
Includes 1 set of multi-connector
40180-03
inserts and connector installation
Connector Protectors. Package instructions. Compatible only
containing 10 pairs of 75Ω with 330153 connector kits or
Coaxial Connector Protectors. with probes shipped in 2003 or
later with ClickLoc connectors
03839410
uninstalled. Supplied with
75Ω Triaxial/95 ohm Coaxial carrying case.
Male Connector Protector.
Placed onto the extension cable;
attaches to the female connector
protector on the 5 mm probe to
Page 10 of 15
Graphs
Figure 1 - Typical 3300 5 mm probe and 1 metre of cable at high and low temperatures (XL Proximitor Sensor and XL extension
cable are at 25°C)
Page 11 of 15
Figure 2 - 3300 5 metre XL Proximitor Sensor at high temperatures (3300 5mm probe and XL extension cable at 25° C)
Dimensional diagrams
Page 12 of 15
1. Probe tip, 5.2 mm [0,21 in] diameter
2. 11.1 mm [7/16 in] for 1/4-28 threads, 13.0 mm [0.51 in] for M8 thread. See Note 3.
3. Case thread
4. 5.6 [7/32] wrench flats for 1/4-28 threads, 7.0 [0.28] for M8 threads
5. 75Ω cable, 2.8 mm [0.11 in] maximum outside diameter, 7.6 mm [0.3 in] outside diameter of armor, 9.0 mm [0.35 in] maximum
diameter of armor ferrule.
6. Miniature male coaxial connector, 7.23 mm [0.285 in] maximum outside diameter “D”
7. 3.2 [0.13 in]
8. Unthreaded length “A”
9. Case length “B”
10. 6.0 mm [0.235 in] maximum
11. Total length “C”, =30%, -0%. See Note 8.
Figure 3 - 3300 5 mm Proximity Probes, Standard Mount3
Page 13 of 15
1. 12 mm [0.40 in] maximumd diameter
2. 36.3 mm [1.43 in] maximum
3. 51.1 mm [2.01 in] maximum
4. Connector protector (fluorosilicone material)
Figure 4 - Installed Connector Protectors
Notes:
1. All dimensions are in millimetres (inches) unless otherwise noted.
3. Standard mount 5 mm probes supplied with 13 mm or 7/16-in lock nut.
5. Letters inside quotation marks refer to probe ordering options.
6. Stainless steel armor is supplied with FEP outer jacket for standard probes, PFA outer jacket for ETR probes.
Specifications and Ordering Information
Part Number 172036
Rev. G (09/09)
Page 14 of 15
7. FEP jacket is standard non-armored portion of the cable for standard probes, PFA jacket on non-armored portion
for ETR probes.
8. Probes ordered with 5 or 9 metre integral cables have a length tolerance of +20%, -0%.
9. Five metre probes are designed for use with the five metre Proximitor Sensor only.
Add notes for missing numbers, even if it is something like “Deleted” or “Note removed”, or renumber the notes in the
document.
* denotes trademarks of Bently Nevada, LLC, a wholly owned subsidiary of General Electric Company.
Page 15 of 15