IMEC-3502 Industrial Automation 2019-10

Mechanical Engineering

Andres Hernandez Infante 201514285

HOMEWORK 5

Sequence

𝑆𝑡𝑎𝑟𝑡, |𝐴+, 𝐵+|, |𝐵−, 𝐶+|, |𝐶−, 𝐴 −|


I II III

Design

Double acting cylinder for the states of each actuator.

Mechanical input from an 3/n Valve spring returned to start the system.

5/n Valve with independent source and switches the piston position according to the
sequence, with pneumatic input and output.

3/n Valve with mechanical input given by a switch in the limits of the pistons and a
neumatic output; spring-recovery.
AND Valve with pneumatic input and output to control the conditions for piston
displacement.

Sequence Line

5/n Valve that act as an interrupter between sequences.

3/n Valve with mechanical input that act as condition to supply sequence interrupt
valves.

3/n Valve at the end of the sequence that acts as an memory valve and
reset the system to initial contitions.