ISO 3183:2007(E) 9.11.2 Mass per unit length ‘The mass per unit length, py, expressed in kilograms per metre (pounds per foot), shall be calculated using Equation (4) paKD=1)xC «4 where Dis the specified outside diameter, expressed in milimetres (inches); tis the specified wall thickness, expressed in millimetres (inches); © {is 0,024 66 for calculations in $1 units and 10.69 for calculations in USC units. No} ‘The nominal mass of a pipe s the product of its length and its mass per unit length 9.11.3 Tolerances for diameter, wall thickness, length and straightness 9.11.3.1 Except as allowed by C.2.3, the diameter and out-of-roundness shall be within the tolerances given in Table 10 (see 1028.2) Table 10 — Tolerances for diameter and out-of-roundness Sposa Diana oeranoes Out af roundhess tolerances ousis metr Sets one Dd .b, — Pipe oxcop te ns * Pipe ena Pipe exept | Pipa : SMLS pipe | Weldedpipe | SMLS pipe | Welded pipe the end end < 60,3 (2.375) = 0,8 (0.031) to + 0.4 (0.016) s waoa @375) 04 (0.0160 +16 (0.065 s 0007s v 1883 (825 7168. (6625) Taare, : wo | ccorsp | nutratmut | 4.4 payne u 610 (24,000) of £3,2 (0.125) i ( ) oars, | amb, cts. | otto) » 610 (24.00) 0008. "O D to 40,01 | butmaximum | £2,0 (0.078) | £1,6(0.083) | 475 | for Pu7s 142288000) of note) =a 6) wes | For SMLS pipe, the tolerances apply for t u 25,0 mm (0.984 in), and the tolerances ‘or thicker pipe shall be as agree 35 egenengmenl OR aabti ahs reserved