Estimated Discharge Pressure, PSIG 9.14 This can be caliculated by using the notes given below. Design Ambient Air Temperature, ºF 85 Estimated Max Ambient Air Temperature, ºF 110 Estimated Relative Humidity, % 30% Esimated Blower Efficiency, C 60.0% Air Constant R 53.5 Air Constant M 28.88 Air Constant K 1.397 Estimated Discharge Temperature, ºF 180.0 Estimated Discharge Viscosity, cP 0.021 Estimated Vapor Pressure 1.275 Estimated Discharge Density, lb/Ft³ 0.100 Actual Air Flow, ACFM 230
Desired Air Velocity in FT/MIN 3000
Line Size in inches 4
NOTES: Cell B3 can be calculated automatically from input data. See below
(Depth of Tank - Free Board - Diffuser Elevation) + 1 m = pressure requirement in m of Water
So if tank depth is 6m, freeboard is 0.5m, and diffuser elevation is 0.2m then diffuser water depth is 6-.5-.2 = 5.3m