Design Airflow, SCFM 310

Site Barometric Pressure, PSIA 14.7


Estimated Discharge Pressure, PSIG 9.14 This can be caliculated by using the notes given below.
Design Ambient Air Temperature, ºF 85
Estimated Max Ambient Air Temperature, ºF 110
Estimated Relative Humidity, % 30%
Esimated Blower Efficiency, C 60.0%
Air Constant R 53.5
Air Constant M 28.88
Air Constant K 1.397
Estimated Discharge Temperature, ºF 180.0
Estimated Discharge Viscosity, cP 0.021
Estimated Vapor Pressure 1.275
Estimated Discharge Density, lb/Ft³ 0.100
Actual Air Flow, ACFM 230

Desired Air Velocity in FT/MIN 3000

Line Size in inches 4

NOTES:
Cell B3 can be calculated automatically from input data.
See below

(Depth of Tank - Free Board - Diffuser Elevation) + 1 m = pressure requirement in m of Water

So if tank depth is 6m, freeboard is 0.5m, and diffuser elevation is 0.2m then diffuser water depth is 6-.5-.2 = 5.3m

5.3m + 1 m = 6.3m pressure required

6.3m water pressure = 630mbar = 9.14 PSIG 1PSIG = 68.95mbar


the notes given below.

depth is 6-.5-.2 = 5.3m