1122 Ue v Us= v Qe Var Enter the measured charging reactive power Qc and the calculated ratio of Uz to U; in a diagram as a function of the corresponding line length. What relationship can you see? Observations Woooscne ‘eytD o0xCTIC Gn 99) 1122 Compare the charging reactive power measured with that which it requires for the corresponding length according to calculation. Result: Charging reactive power power calculated: Q. = Uj -w- Cy For |= 144 km: Qc = 91 Var (measured Var) For |= 216 km: Qc = 136 Var (measured Var) For |= 360 km: Qc = 227 Var (measured Var) Does the transmission line model also require active power in no-load operation? Answer: Devore ‘eytD o0xCTIC Gn cir) To demonstrate the concept of "operating capacitance", assemble the following circuit Set the voltage at the three-phase transformer to the value Uy - 10%; remove all bridging plugs connecting the capacitances to the transmission line model. Measure the voltage between the two outer conductors at the beginning and end of each line, as well as the reactive power consumed by a phase: Ue v Us v ratio UziUy = Qc = Var Compare the result with that for the transmission line model at a length of 100%. What conclusion can you draw regarding the equivalent capacitance? Answer: Wocorcne ‘eoytD o0ACTIC Ge 90