Professional Documents
Culture Documents
M3
INSUMO 1 2 3 4 5 6
CEMENTO (KG.) 385.00 770.00 1155.00 1540.00 1925.00 2310.00
ARENA (KG.) 1600.00 3200.00 4800.00 6400.00 8000.00 9600.00
FILLER CALIZO 40.50 81.00 121.50 162.00 202.50 243.00
RHEOBUILD 1000 (LT.) 4.60 9.20 13.80 18.40 23.00 27.60
FIBRA ENDURO (KG.) 4.00 8.00 12.00 16.00 20.00 24.00
MEYCO SA 160 (LT.) 23.20 46.40 69.60 92.80 116.00 139.20
DELVO (LT.) 1.90 3.80 5.70 7.60 9.50 11.40
AGUA (LT.) 235.24 470.48 705.72 940.96 1176.20 1411.44
7 8
2695.00 3080.00
11200.00 12800.00
283.50 324.00
32.20 36.80
28.00 32.00
162.40 185.60
13.30 15.20
1646.68 1881.92
PLANTA COBRIZA
DISEÑO DE SHOTCRETE CON FILLER CALIZO – FIBRA ENDURO CORREGIDO POR HUMEDAD
CODIGO 1306CSH1B-6
f´c = 306 kg/cm2
HUMEDAD 2.5 %
ABSORCIÓN 1.8 %
ARENA 1600.0 KG.
M3
INSUMO 1 2 3 4 5 6 7 8
CEMENTO (KG.) 385.00 770.00 1155.00 1540.00 1925.00 2310.00 2695.00 3080.00
ARENA (KG.) 1640.00 3280.00 4920.00 6560.00 8200.00 9840.00 11480.00 13120.00
FILLER CALIZO 40.50 81.00 121.50 162.00 202.50 243.00 283.50 324.00
RHEOBUILD 1000 (LT.) 4.60 9.20 13.80 18.40 23.00 27.60 32.20 36.80
FIBRA ENDURO (KG.) 4.00 8.00 12.00 16.00 20.00 24.00 28.00 32.00
MEYCO SA 160 (LT.) 23.20 46.40 69.60 92.80 116.00 139.20 162.40 185.60
DELVO (LT.) 1.90 3.80 5.70 7.60 9.50 11.40 13.30 15.20
AGUA (LT.) 200.36 400.72 601.08 801.44 1001.80 1202.16 1402.52 1602.88
PLANTA COBRIZA
DISEÑO DE SHOTCRETE CON FILLER CALIZO – FIBRA ENDURO CORREGIDO POR HUMEDAD
CODIGO 1306CSH1B-6
f´c = 306 kg/cm2
HUMEDAD 3.0 %
ABSORCIÓN 1.4 %
ARENA 1600.0 KG.
M3
INSUMO 1 2 3 4 5 6 7 8
CEMENTO (KG.) 385.00 770.00 1155.00 1540.00 1925.00 2310.00 2695.00 3080.00
ARENA (KG.) 1648.00 3296.00 4944.00 6592.00 8240.00 9888.00 11536.00 13184.00
FILLER CALIZO 40.50 81.00 121.50 162.00 202.50 243.00 283.50 324.00
RHEOBUILD 1000 (LT.) 4.60 9.20 13.80 18.40 23.00 27.60 32.20 36.80
FIBRA ENDURO (KG.) 4.00 8.00 12.00 16.00 20.00 24.00 28.00 32.00
MEYCO SA 160 (LT.) 23.20 46.40 69.60 92.80 116.00 139.20 162.40 185.60
DELVO (LT.) 1.90 3.80 5.70 7.60 9.50 11.40 13.30 15.20
AGUA (LT.) 187.24 374.48 561.72 748.96 936.20 1123.44 1310.68 1497.92
PLANTA COBRIZA
DISEÑO DE SHOTCRETE CON FILLER CALIZO – FIBRA ENDURO CORREGIDO POR HUMEDAD
CODIGO 1306CSH1B-6
f´c = 306 kg/cm2
HUMEDAD 3.5 %
ABSORCIÓN 1.4 %
ARENA 1600.0 KG.
M3
INSUMO 1 2 3 4 5 6 7 8
CEMENTO (KG.) 385.00 770.00 1155.00 1540.00 1925.00 2310.00 2695.00 3080.00
ARENA (KG.) 1656.00 3312.00 4968.00 6624.00 8280.00 9936.00 11592.00 13248.00
FILLER CALIZO 40.50 81.00 121.50 162.00 202.50 243.00 283.50 324.00
RHEOBUILD 1000 (LT.) 4.60 9.20 13.80 18.40 23.00 27.60 32.20 36.80
FIBRA ENDURO (KG.) 4.00 8.00 12.00 16.00 20.00 24.00 28.00 32.00
MEYCO SA 160 (LT.) 23.20 46.40 69.60 92.80 116.00 139.20 162.40 185.60
DELVO (LT.) 1.90 3.80 5.70 7.60 9.50 11.40 13.30 15.20
AGUA (LT.) 179.24 358.48 537.72 716.96 896.20 1075.44 1254.68 1433.92
PLANTA COBRIZA
DISEÑO DE SHOTCRETE CON FILLER CALIZO – FIBRA ENDURO CORREGIDO POR HUMEDAD
CODIGO 1306CSH1B-6
f´c = 306 kg/cm2
HUMEDAD 4.0 %
ABSORCIÓN 1.4 %
ARENA 1600.0 KG.
M3
INSUMO 1 2 3 4 5 6 7 8
CEMENTO (KG.) 385.00 770.00 1155.00 1540.00 1925.00 2310.00 2695.00 3080.00
ARENA (KG.) 1664.00 3328.00 4992.00 6656.00 8320.00 9984.00 11648.00 13312.00
FILLER CALIZO 40.50 81.00 121.50 162.00 202.50 243.00 283.50 324.00
RHEOBUILD 1000 (LT.) 4.60 9.20 13.80 18.40 23.00 27.60 32.20 36.80
FIBRA ENDURO (KG.) 4.00 8.00 12.00 16.00 20.00 24.00 28.00 32.00
MEYCO SA 160 (LT.) 23.20 46.40 69.60 92.80 116.00 139.20 162.40 185.60
DELVO (LT.) 1.90 3.80 5.70 7.60 9.50 11.40 13.30 15.20
AGUA (LT.) 171.24 342.48 513.72 684.96 856.20 1027.44 1198.68 1369.92
PLANTA COBRIZA
DISEÑO DE SHOTCRETE CON FILLER CALIZO – FIBRA ENDURO CORREGIDO POR HUMEDAD
CODIGO 1306CSH1B-6
f´c = 306 kg/cm2
HUMEDAD 4.5 %
ABSORCIÓN 1.4 %
ARENA 1600.0 KG.
M3
INSUMO 1 2 3 4 5 6 7 8
CEMENTO (KG.) 385.00 770.00 1155.00 1540.00 1925.00 2310.00 2695.00 3080.00
ARENA (KG.) 1672.00 3344.00 5016.00 6688.00 8360.00 10032.00 11704.00 13376.00
FILLER CALIZO 40.50 81.00 121.50 162.00 202.50 243.00 283.50 324.00
RHEOBUILD 1000 (LT.) 4.60 9.20 13.80 18.40 23.00 27.60 32.20 36.80
FIBRA ENDURO (KG.) 4.00 8.00 12.00 16.00 20.00 24.00 28.00 32.00
MEYCO SA 160 (LT.) 23.20 46.40 69.60 92.80 116.00 139.20 162.40 185.60
DELVO (LT.) 1.90 3.80 5.70 7.60 9.50 11.40 13.30 15.20
AGUA (LT.) 163.24 326.48 489.72 652.96 816.20 979.44 1142.68 1305.92
PLANTA COBRIZA
DISEÑO DE SHOTCRETE CON FILLER CALIZO – FIBRA ENDURO CORREGIDO POR HUMEDAD
CODIGO 1306CSH1B-6
f´c = 306 kg/cm2
HUMEDAD 5.0 %
ABSORCIÓN 1.4 %
ARENA 1600.0 KG.
M3
INSUMO 1 2 3 4 5 6 7 8
CEMENTO (KG.) 385.00 770.00 1155.00 1540.00 1925.00 2310.00 2695.00 3080.00
ARENA (KG.) 1680.00 3360.00 5040.00 6720.00 8400.00 10080.00 11760.00 13440.00
FILLER CALIZO 40.50 81.00 121.50 162.00 202.50 243.00 283.50 324.00
RHEOBUILD 1000 (LT.) 4.60 9.20 13.80 18.40 23.00 27.60 32.20 36.80
FIBRA ENDURO (KG.) 4.00 8.00 12.00 16.00 20.00 24.00 28.00 32.00
MEYCO SA 160 (LT.) 23.20 46.40 69.60 92.80 116.00 139.20 162.40 185.60
DELVO (LT.) 1.90 3.80 5.70 7.60 9.50 11.40 13.30 15.20
AGUA (LT.) 155.24 310.48 465.72 620.96 776.20 931.44 1086.68 1241.92
PLANTA COBRIZA
DISEÑO DE SHOTCRETE CON FILLER CALIZO – FIBRA ENDURO CORREGIDO POR HUMEDAD
CODIGO 1306CSH1B-6
f´c = 306 kg/cm2
HUMEDAD 5.5 %
ABSORCIÓN 1.4 %
ARENA 1600.0 KG.
M3
INSUMO 1 2 3 4 5 6 7 8
CEMENTO (KG.) 385.00 770.00 1155.00 1540.00 1925.00 2310.00 2695.00 3080.00
ARENA (KG.) 1688.00 3376.00 5064.00 6752.00 8440.00 10128.00 11816.00 13504.00
FILLER CALIZO 40.50 81.00 121.50 162.00 202.50 243.00 283.50 324.00
RHEOBUILD 1000 (LT.) 4.60 9.20 13.80 18.40 23.00 27.60 32.20 36.80
FIBRA ENDURO (KG.) 4.00 8.00 12.00 16.00 20.00 24.00 28.00 32.00
MEYCO SA 160 (LT.) 23.20 46.40 69.60 92.80 116.00 139.20 162.40 185.60
DELVO (LT.) 1.90 3.80 5.70 7.60 9.50 11.40 13.30 15.20
AGUA (LT.) 147.24 294.48 441.72 588.96 736.20 883.44 1030.68 1177.92
PLANTA COBRIZA
DISEÑO DE SHOTCRETE CON FILLER CALIZO – FIBRA ENDURO CORREGIDO POR HUMEDAD
CODIGO 1306CSH1B-6
f´c = 306 kg/cm2
HUMEDAD 6.0 %
ABSORCIÓN 1.4 %
ARENA 1600.0 KG.
M3
INSUMO 1 2 3 4 5 6 7 8
CEMENTO (KG.) 385.00 770.00 1155.00 1540.00 1925.00 2310.00 2695.00 3080.00
ARENA (KG.) 1696.00 3392.00 5088.00 6784.00 8480.00 10176.00 11872.00 13568.00
FILLER CALIZO 40.50 81.00 121.50 162.00 202.50 243.00 283.50 324.00
RHEOBUILD 1000 (LT.) 4.60 9.20 13.80 18.40 23.00 27.60 32.20 36.80
FIBRA ENDURO (KG.) 4.00 8.00 12.00 16.00 20.00 24.00 28.00 32.00
MEYCO SA 160 (LT.) 23.20 46.40 69.60 92.80 116.00 139.20 162.40 185.60
DELVO (LT.) 1.90 3.80 5.70 7.60 9.50 11.40 13.30 15.20
AGUA (LT.) 139.24 278.48 417.72 556.96 696.20 835.44 974.68 1113.92
PLANTA COBRIZA
DISEÑO DE SHOTCRETE CON FILLER CALIZO – FIBRA ENDURO CORREGIDO POR HUMEDAD
CODIGO 1306CSH1B-6
f´c = 306 kg/cm2
HUMEDAD 6.5 %
ABSORCIÓN 1.4 %
ARENA 1600.0 KG.
M3
INSUMO 1 2 3 4 5 6 7 8
CEMENTO (KG.) 385.00 770.00 1155.00 1540.00 1925.00 2310.00 2695.00 3080.00
ARENA (KG.) 1704.00 3408.00 5112.00 6816.00 8520.00 10224.00 11928.00 13632.00
FILLER CALIZO 40.50 81.00 121.50 162.00 202.50 243.00 283.50 324.00
RHEOBUILD 1000 (LT.) 4.60 9.20 13.80 18.40 23.00 27.60 32.20 36.80
FIBRA ENDURO (KG.) 4.00 8.00 12.00 16.00 20.00 24.00 28.00 32.00
MEYCO SA 160 (LT.) 23.20 46.40 69.60 92.80 116.00 139.20 162.40 185.60
DELVO (LT.) 1.90 3.80 5.70 7.60 9.50 11.40 13.30 15.20
AGUA (LT.) 131.24 262.48 393.72 524.96 656.20 787.44 918.68 1049.92
PLANTA COBRIZA
DISEÑO DE SHOTCRETE CON FILLER CALIZO – FIBRA ENDURO CORREGIDO POR HUMEDAD
CODIGO 1306CSH1B-6
f´c = 306 kg/cm2
HUMEDAD 7.0 %
ABSORCIÓN 1.4 %
ARENA 1600.0 KG.
M3
INSUMO 1 2 3 4 5 6 7 8
CEMENTO (KG.) 385.00 770.00 1155.00 1540.00 1925.00 2310.00 2695.00 3080.00
ARENA (KG.) 1712.00 3424.00 5136.00 6848.00 8560.00 10272.00 11984.00 13696.00
FILLER CALIZO 40.50 81.00 121.50 162.00 202.50 243.00 283.50 324.00
RHEOBUILD 1000 (LT.) 4.60 9.20 13.80 18.40 23.00 27.60 32.20 36.80
FIBRA ENDURO (KG.) 4.00 8.00 12.00 16.00 20.00 24.00 28.00 32.00
MEYCO SA 160 (LT.) 23.20 46.40 69.60 92.80 116.00 139.20 162.40 185.60
DELVO (LT.) 1.90 3.80 5.70 7.60 9.50 11.40 13.30 15.20
AGUA (LT.) 123.24 246.48 369.72 492.96 616.20 739.44 862.68 985.92
PLANTA COBRIZA
DISEÑO DE SHOTCRETE CON FILLER CALIZO – FIBRA ENDURO CORREGIDO POR HUMEDAD
CODIGO 1306CSH1B-6
f´c = 306 kg/cm2
HUMEDAD 7.5 %
ABSORCIÓN 1.4 %
ARENA 1600.0 KG.
M3
INSUMO 1 2 3 4 5 6 7 8
CEMENTO (KG.) 385.00 770.00 1155.00 1540.00 1925.00 2310.00 2695.00 3080.00
ARENA (KG.) 1720.00 3440.00 5160.00 6880.00 8600.00 10320.00 12040.00 13760.00
FILLER CALIZO 40.50 81.00 121.50 162.00 202.50 243.00 283.50 324.00
RHEOBUILD 1000 (LT.) 4.60 9.20 13.80 18.40 23.00 27.60 32.20 36.80
FIBRA ENDURO (KG.) 4.00 8.00 12.00 16.00 20.00 24.00 28.00 32.00
MEYCO SA 160 (LT.) 23.20 46.40 69.60 92.80 116.00 139.20 162.40 185.60
DELVO (LT.) 1.90 3.80 5.70 7.60 9.50 11.40 13.30 15.20
AGUA (LT.) 115.24 230.48 345.72 460.96 576.20 691.44 806.68 921.92
PLANTA COBRIZA
DISEÑO DE SHOTCRETE CON FILLER CALIZO – FIBRA ENDURO CORREGIDO POR HUMEDAD
CODIGO 1306CSH1B-6
f´c = 306 kg/cm2
HUMEDAD 8.0 %
ABSORCIÓN 1.4 %
ARENA 1600.0 KG.
M3
INSUMO 1 2 3 4 5 6 7 8
CEMENTO (KG.) 385.00 770.00 1155.00 1540.00 1925.00 2310.00 2695.00 3080.00
ARENA (KG.) 1728.00 3456.00 5184.00 6912.00 8640.00 10368.00 12096.00 13824.00
FILLER CALIZO 40.50 81.00 121.50 162.00 202.50 243.00 283.50 324.00
RHEOBUILD 1000 (LT.) 4.60 9.20 13.80 18.40 23.00 27.60 32.20 36.80
FIBRA ENDURO (KG.) 4.00 8.00 12.00 16.00 20.00 24.00 28.00 32.00
MEYCO SA 160 (LT.) 23.20 46.40 69.60 92.80 116.00 139.20 162.40 185.60
DELVO (LT.) 1.90 3.80 5.70 7.60 9.50 11.40 13.30 15.20
AGUA (LT.) 107.24 214.48 321.72 428.96 536.20 643.44 750.68 857.92
PLANTA COBRIZA
DISEÑO DE SHOTCRETE CON FILLER CALIZO – FIBRA ENDURO CORREGIDO POR HUMEDAD
CODIGO 1306CSH1B-6
f´c = 306 kg/cm2
HUMEDAD 8.5 %
ABSORCIÓN 1.4 %
ARENA 1600.0 KG.
M3
INSUMO 1 2 3 4 5 6 7 8
CEMENTO (KG.) 385.00 770.00 1155.00 1540.00 1925.00 2310.00 2695.00 3080.00
ARENA (KG.) 1736.00 3472.00 5208.00 6944.00 8680.00 10416.00 12152.00 13888.00
FILLER CALIZO 40.50 81.00 121.50 162.00 202.50 243.00 283.50 324.00
RHEOBUILD 1000 (LT.) 4.60 9.20 13.80 18.40 23.00 27.60 32.20 36.80
FIBRA ENDURO (KG.) 4.00 8.00 12.00 16.00 20.00 24.00 28.00 32.00
MEYCO SA 160 (LT.) 23.20 46.40 69.60 92.80 116.00 139.20 162.40 185.60
DELVO (LT.) 1.90 3.80 5.70 7.60 9.50 11.40 13.30 15.20
AGUA (LT.) 99.24 198.48 297.72 396.96 496.20 595.44 694.68 793.92
PLANTA COBRIZA
DISEÑO DE SHOTCRETE CON FILLER CALIZO – FIBRA ENDURO CORREGIDO POR HUMEDAD
CODIGO 1306CSH1B-6
f´c = 306 kg/cm2
HUMEDAD 9.0 %
ABSORCIÓN 1.4 %
ARENA 1600.0 KG.
M3
INSUMO 1 2 3 4 5 6 7 8
CEMENTO (KG.) 385.00 770.00 1155.00 1540.00 1925.00 2310.00 2695.00 3080.00
ARENA (KG.) 1744.00 3488.00 5232.00 6976.00 8720.00 10464.00 12208.00 13952.00
FILLER CALIZO 40.50 81.00 121.50 162.00 202.50 243.00 283.50 324.00
RHEOBUILD 1000 (LT.) 4.60 9.20 13.80 18.40 23.00 27.60 32.20 36.80
FIBRA ENDURO (KG.) 4.00 8.00 12.00 16.00 20.00 24.00 28.00 32.00
MEYCO SA 160 (LT.) 23.20 46.40 69.60 92.80 116.00 139.20 162.40 185.60
DELVO (LT.) 1.90 3.80 5.70 7.60 9.50 11.40 13.30 15.20
AGUA (LT.) 91.24 182.48 273.72 364.96 456.20 547.44 638.68 729.92
PLANTA COBRIZA
DISEÑO DE SHOTCRETE CON FILLER CALIZO – FIBRA ENDURO CORREGIDO POR HUMEDAD
CODIGO 1306CSH1B-6
f´c = 306 kg/cm2
HUMEDAD 9.5 %
ABSORCIÓN 1.4 %
ARENA 1600.0 KG.
M3
INSUMO 1 2 3 4 5 6 7 8
CEMENTO (KG.) 385.00 770.00 1155.00 1540.00 1925.00 2310.00 2695.00 3080.00
ARENA (KG.) 1752.00 3504.00 5256.00 7008.00 8760.00 10512.00 12264.00 14016.00
FILLER CALIZO 40.50 81.00 121.50 162.00 202.50 243.00 283.50 324.00
RHEOBUILD 1000 (LT.) 4.60 9.20 13.80 18.40 23.00 27.60 32.20 36.80
FIBRA ENDURO (KG.) 4.00 8.00 12.00 16.00 20.00 24.00 28.00 32.00
MEYCO SA 160 (LT.) 23.20 46.40 69.60 92.80 116.00 139.20 162.40 185.60
DELVO (LT.) 1.90 3.80 5.70 7.60 9.50 11.40 13.30 15.20
AGUA (LT.) 83.24 166.48 249.72 332.96 416.20 499.44 582.68 665.92
PLANTA COBRIZA
DISEÑO DE SHOTCRETE CON FILLER CALIZO – FIBRA ENDURO CORREGIDO POR HUMEDAD
CODIGO 1306CSH1B-6
f´c = 306 kg/cm2
HUMEDAD 10.0 %
ABSORCIÓN 1.4 %
ARENA 1600.0 KG.
M3
INSUMO 1 2 3 4 5 6 7 8
CEMENTO (KG.) 385.00 770.00 1155.00 1540.00 1925.00 2310.00 2695.00 3080.00
ARENA (KG.) 1760.00 3520.00 5280.00 7040.00 8800.00 10560.00 12320.00 14080.00
FILLER CALIZO 40.50 81.00 121.50 162.00 202.50 243.00 283.50 324.00
RHEOBUILD 1000 (LT.) 4.60 9.20 13.80 18.40 23.00 27.60 32.20 36.80
FIBRA ENDURO (KG.) 4.00 8.00 12.00 16.00 20.00 24.00 28.00 32.00
MEYCO SA 160 (LT.) 23.20 46.40 69.60 92.80 116.00 139.20 162.40 185.60
DELVO (LT.) 1.90 3.80 5.70 7.60 9.50 11.40 13.30 15.20
AGUA (LT.) 75.24 150.48 225.72 300.96 376.20 451.44 526.68 601.92
PLANTA COBRIZA
DISEÑO DE SHOTCRETE CON FILLER CALIZO – FIBRA ENDURO CORREGIDO POR HUMEDAD
CODIGO 1306CSH1B-6
f´c = 306 kg/cm2
HUMEDAD 10.5 %
ABSORCIÓN 1.4 %
ARENA 1600.0 KG.
M3
INSUMO 1 2 3 4 5 6 7 8
CEMENTO (KG.) 385.00 770.00 1155.00 1540.00 1925.00 2310.00 2695.00 3080.00
ARENA (KG.) 1768.00 3536.00 5304.00 7072.00 8840.00 10608.00 12376.00 14144.00
FILLER CALIZO 40.50 81.00 121.50 162.00 202.50 243.00 283.50 324.00
RHEOBUILD 1000 (LT.) 4.60 9.20 13.80 18.40 23.00 27.60 32.20 36.80
FIBRA ENDURO (KG.) 4.00 8.00 12.00 16.00 20.00 24.00 28.00 32.00
MEYCO SA 160 (LT.) 23.20 46.40 69.60 92.80 116.00 139.20 162.40 185.60
DELVO (LT.) 1.90 3.80 5.70 7.60 9.50 11.40 13.30 15.20
AGUA (LT.) 67.24 134.48 201.72 268.96 336.20 403.44 470.68 537.92
PLANTA COBRIZA
DISEÑO DE SHOTCRETE CON FILLER CALIZO – FIBRA ENDURO CORREGIDO POR HUMEDAD
CODIGO 1306CSH1B-6
f´c = 306 kg/cm2
HUMEDAD 11.0 %
ABSORCIÓN 1.4 %
ARENA 1600.0 KG.
M3
INSUMO 1 2 3 4 5 6 7 8
CEMENTO (KG.) 385.00 770.00 1155.00 1540.00 1925.00 2310.00 2695.00 3080.00
ARENA (KG.) 1776.00 3552.00 5328.00 7104.00 8880.00 10656.00 12432.00 14208.00
FILLER CALIZO 40.50 81.00 121.50 162.00 202.50 243.00 283.50 324.00
RHEOBUILD 1000 (LT.) 4.60 9.20 13.80 18.40 23.00 27.60 32.20 36.80
FIBRA ENDURO (KG.) 4.00 8.00 12.00 16.00 20.00 24.00 28.00 32.00
MEYCO SA 160 (LT.) 23.20 46.40 69.60 92.80 116.00 139.20 162.40 185.60
DELVO (LT.) 1.90 3.80 5.70 7.60 9.50 11.40 13.30 15.20
AGUA (LT.) 59.24 118.48 177.72 236.96 296.20 355.44 414.68 473.92
PLANTA COBRIZA
DISEÑO DE SHOTCRETE CON FILLER CALIZO – FIBRA ENDURO CORREGIDO POR HUMEDAD
CODIGO 1306CSH1B-6
f´c = 306 kg/cm2
HUMEDAD 11.5 %
ABSORCIÓN 1.4 %
ARENA 1600.0 KG.
M3
INSUMO 1 2 3 4 5 6 7 8
CEMENTO (KG.) 385.00 770.00 1155.00 1540.00 1925.00 2310.00 2695.00 3080.00
ARENA (KG.) 1784.00 3568.00 5352.00 7136.00 8920.00 10704.00 12488.00 14272.00
FILLER CALIZO 40.50 81.00 121.50 162.00 202.50 243.00 283.50 324.00
RHEOBUILD 1000 (LT.) 4.60 9.20 13.80 18.40 23.00 27.60 32.20 36.80
FIBRA ENDURO (KG.) 4.00 8.00 12.00 16.00 20.00 24.00 28.00 32.00
MEYCO SA 160 (LT.) 23.20 46.40 69.60 92.80 116.00 139.20 162.40 185.60
DELVO (LT.) 1.90 3.80 5.70 7.60 9.50 11.40 13.30 15.20
AGUA (LT.) 51.24 102.48 153.72 204.96 256.20 307.44 358.68 409.92
PLANTA COBRIZA
DISEÑO DE SHOTCRETE CON FILLER CALIZO – FIBRA ENDURO CORREGIDO POR HUMEDAD
CODIGO 1306CSH1B-6
f´c = 306 kg/cm2
HUMEDAD 12.0 %
ABSORCIÓN 1.4 %
ARENA 1600.0 KG.
M3
INSUMO 1 2 3 4 5 6 7 8
CEMENTO (KG.) 385.00 770.00 1155.00 1540.00 1925.00 2310.00 2695.00 3080.00
ARENA (KG.) 1792.00 3584.00 5376.00 7168.00 8960.00 10752.00 12544.00 14336.00
FILLER CALIZO 40.50 81.00 121.50 162.00 202.50 243.00 283.50 324.00
RHEOBUILD 1000 (LT.) 4.60 9.20 13.80 18.40 23.00 27.60 32.20 36.80
FIBRA ENDURO (KG.) 4.00 8.00 12.00 16.00 20.00 24.00 28.00 32.00
MEYCO SA 160 (LT.) 23.20 46.40 69.60 92.80 116.00 139.20 162.40 185.60
DELVO (LT.) 1.90 3.80 5.70 7.60 9.50 11.40 13.30 15.20
AGUA (LT.) 43.24 86.48 129.72 172.96 216.20 259.44 302.68 345.92
PLANTA COBRIZA
DISEÑO DE SHOTCRETE CON FILLER CALIZO – FIBRA ENDURO CORREGIDO POR HUMEDAD
CODIGO 1306CSH1B-6
f´c = 306 kg/cm2
HUMEDAD 12.5 %
ABSORCIÓN 1.4 %
ARENA 1600.0 KG.
M3
INSUMO 1 2 3 4 5 6 7 8
CEMENTO (KG.) 385.00 770.00 1155.00 1540.00 1925.00 2310.00 2695.00 3080.00
ARENA (KG.) 1800.00 3600.00 5400.00 7200.00 9000.00 10800.00 12600.00 14400.00
FILLER CALIZO 40.50 81.00 121.50 162.00 202.50 243.00 283.50 324.00
RHEOBUILD 1000 (LT.) 4.60 9.20 13.80 18.40 23.00 27.60 32.20 36.80
FIBRA ENDURO (KG.) 4.00 8.00 12.00 16.00 20.00 24.00 28.00 32.00
MEYCO SA 160 (LT.) 23.20 46.40 69.60 92.80 116.00 139.20 162.40 185.60
DELVO (LT.) 1.90 3.80 5.70 7.60 9.50 11.40 13.30 15.20
AGUA (LT.) 35.24 70.48 105.72 140.96 176.20 211.44 246.68 281.92
PLANTA COBRIZA
DISEÑO DE SHOTCRETE CON FILLER CALIZO – FIBRA ENDURO CORREGIDO POR HUMEDAD
CODIGO 1306CSH1B-6
f´c = 306 kg/cm2
HUMEDAD 13.0 %
ABSORCIÓN 1.4 %
ARENA 1600.0 KG.
M3
INSUMO 1 2 3 4 5 6 7 8
CEMENTO (KG.) 385.00 770.00 1155.00 1540.00 1925.00 2310.00 2695.00 3080.00
ARENA (KG.) 1808.00 3616.00 5424.00 7232.00 9040.00 10848.00 12656.00 14464.00
FILLER CALIZO 40.50 81.00 121.50 162.00 202.50 243.00 283.50 324.00
RHEOBUILD 1000 (LT.) 4.60 9.20 13.80 18.40 23.00 27.60 32.20 36.80
FIBRA ENDURO (KG.) 4.00 8.00 12.00 16.00 20.00 24.00 28.00 32.00
MEYCO SA 160 (LT.) 23.20 46.40 69.60 92.80 116.00 139.20 162.40 185.60
DELVO (LT.) 1.90 3.80 5.70 7.60 9.50 11.40 13.30 15.20
AGUA (LT.) 27.24 54.48 81.72 108.96 136.20 163.44 190.68 217.92
PLANTA COBRIZA
DISEÑO DE SHOTCRETE CON FILLER CALIZO – FIBRA ENDURO CORREGIDO POR HUMEDAD
CODIGO 1306CSH1B-6
f´c = 306 kg/cm2
HUMEDAD 13.5 %
ABSORCIÓN 1.4 %
ARENA 1600.0 KG.
M3
INSUMO 1 2 3 4 5 6 7 8
CEMENTO (KG.) 385.00 770.00 1155.00 1540.00 1925.00 2310.00 2695.00 3080.00
ARENA (KG.) 1816.00 3632.00 5448.00 7264.00 9080.00 10896.00 12712.00 14528.00
FILLER CALIZO 40.50 81.00 121.50 162.00 202.50 243.00 283.50 324.00
RHEOBUILD 1000 (LT.) 4.60 9.20 13.80 18.40 23.00 27.60 32.20 36.80
FIBRA ENDURO (KG.) 4.00 8.00 12.00 16.00 20.00 24.00 28.00 32.00
MEYCO SA 160 (LT.) 23.20 46.40 69.60 92.80 116.00 139.20 162.40 185.60
DELVO (LT.) 1.90 3.80 5.70 7.60 9.50 11.40 13.30 15.20
AGUA (LT.) 19.24 38.48 57.72 76.96 96.20 115.44 134.68 153.92