You are on page 1of 3

Syngas

Ambient Temp 3.08E+02 K


Viscosity 1.91E-05 Pa S Sutherland formula

Density @ Density @
DP, 273k, Gas Temp, gas Temp,
Tag No mmWC DP, Pa kg/m3 C kg/m3 Cd
FE-660 80.00 784.00 1.12 100.00 0.82 0.6091
FE-660 80.00 784.00 1.12 200.00 0.65 0.6091

When actual ID fan exit Temp 100 deg C


SCADA reading 712.72 Nm3/hr
Actual flow 802.59

Corrected flow corresponding to


actual temperature 802.59235
Syngas Mass flow 898.90 kg/hr
Exp Pipe Orifice Orifce Flow Vel, Flow, Flow rate, Flow,
Coefficient Dia,mm Dia, mm Area, m2 Dia Ratio m/s Nm3/s Nm3/h Am3/s
0.9143 154.05 114.99 0.0104 0.746 21.468 0.22 802.59 0.30
0.9143 154.05 114.99 0.0104 0.746 19.064 0.20 712.72 0.34
Flow rate,
Am3/h Re Cd Cd *orifice area Sqrt(2*DP)/Sqrt(density*(1-b4)
1,096.58 105,966.74 0.65
1,234.86 74,206.36 0.65

You might also like