SYMPTOM
FAILURE : Crack, Dent, Worn, Scratch, Short Circuit, Burn, Bend, Loose, Rusty, Pitting, Broken etc
ELBOW BROKEN
CAUSED ANALYSIS : (Describe detail of failure, analysis the cause, operating condition & ATTACHED PHOTOGRAPHS or Drawing)
DATA :
AUTOLUBE MALFUNCTION, GREASE TIDAK TERDISTRIBUSI KE PIN DAN BUSHING ATTACHMENT. HAL INI DISEBABKAN OLEH ELBOW GREASE VANE VALVE BROKEN.
ELBOW BROKEN DISEBABKAN OLEH OVER TORQUE SAAT ASSEMBLING DAN TIDAK ADANYA BRACKET PENOPANG CIRCUIT PRESSURE GAUGE. SEHINGGA TUMPUAN
BERAT ADA PADA ELBOW.
CORRECTION MADE
REPLACE ELBOW, ADD BRACKET MOUNTING PRESSURE GAUGE (WAITING PARTS FROM INTECS)
CONCLUSION
( MARWANTO ) ( SVP/SDH )