You are on page 1of 2

Specification, picture, dimension may change without notice due to product improvement.

General
Genset Type : BG500P
Rating : 400kW / 500kVA (Prime Power)
: 440kW / 550kVA (Standby Power)
Fuel Consumption : 107.2 l/h (Prime Power), 117.8 l/h (Standby Power)

Rating Definition
Limited-Time Running Power (LTP): Prime Power (PRP):
Applicable for supplying power to a constant Applicable for supplying power to varying
electrical load for limited hours. Limited-Time electrical load for unlimited hours. Prime
Running Power (LTP) is in accordance with Power (PRP) is in accordance with ISO 8528.
ISO 8528. Ten percent overload capability is available in
accordance with ISO 3046, AS 2789,
DIN 6271 and BS 5514.

Engine Data Alternator Data


Type : 2506C-E15TAG2 Type : STAMFORD
Speed [Rpm] : 1500 : [3Ph, Single Bearing]
Frequency (Hz) : 50 Rated Output [kVA] : 500
No of cylinders : 6 (in-line) Speed [Rpm] : 1500
Displacement [l] : 15.2 Frequency [Hz] : 50
Bore/Stroke [mm] : 137 / 171 Voltage [V] : 400/230
Compression Ratio : 16 : 1 Insulation : Class H
Governor : Electronic Protection : IP 23
Oil Capacity [l] : 62
Cooling System and Accessories
Radiator Cooling : as Perkins standard
Coolant Capacity [l] : 58 (engine only)
Starting Volt. : 24V
Exhaust System : Industrial / residential exhaust silencer
Baseframe : Steel Channel/Plate construction (incl. 8hrs daily tank)
Engine and Alternator Mounting : Rubber metal elements
Set of Operation books, consist of : Engine operating instruction
: Certificate of Origin
: Alternator operating instruction
: Genset Test Report

Genset Controller

ComAp InteliLite AMF20


Auto Mains (Utility) Failure Control Modules

KEY FEATURES
-Meets all requirements for Auto Mains Failure (AMF)
applications
-Full gen-set monitoring and protection
-Running hours event and performance log
-Multiple languages (user changeable) in controller, even
more in installation suite
-On-line control and monitoring over web pages (embedded
web server) via plug & play IB-Lite
- Earth fault current protection (plug-in mode required)
-Automatic and manual GCB and MCB control
-3 phase power measurement of gen-set and mains incl.
kWh
-etc

Genset Dimension and Dry Weight


Open Type Silent Type
Dimension [LxWxH] : 3500x1260x2000(mm) Dimension [LxWxH] : 4570x1420x2200(mm)
Dry Weight : 3870(kg) Dry Weight : 5330kg

OPEN TYPE SILENT TYPE

PT. Tan Energy Indonesia (TANEKO)


Alamanda Tower Lt. 28-D
Jl. TB Simatupang Kav. 23-24 Cilandak Barat
Jakarta 12430 – Indonesia
Ph. +6221 - 75905072, +6221 - 75905073
Email : marketing@taneko.co.id
Website : www.taneko.co.id PRODUCT OF ARVON CORP INTERNATIONAL

According to ISO 8528-5. Continuous Power: No time limitation, plus 10% addictional, power for governing purpose only. Prime Power: Average output ≤ 80%, no time limitation, plus 5%
addictional power for governing purpose only. Limited Time Running Power: for up to 500 h/year, thereof a maximum of 300 h/year continuous running. In consideration of a generator
efficiency level of 89% - 90% and a power factor of 0.8