OMSN-WDM CABLES costruction table
MATERIALS LIST
UTP Cat 5 cable
RJ-45 8 PIN NOT SHIELDED connectors.with protection on RU-45
Cannon 9 PIN male and female with plastic or iron shells
Colors and sequency of single wire has to be respected just for
those: (1 straight cable specific EIA 568 A) (2'Cross over cable
specific EIA 568 B)
Straight cable specific EIA 568 A
Crossover cable specific EIA 568 B
Straight cable (Pin to Pin) for CRAFT TERMINAL (OMSN-DWDM)
CRAFT-TERMINAL CABLE (Pin to Pin) 1678MCC EQUIPMENT
DEBUG CABLE (FLC DEBUG-EMO04A - DCR) 1678MCC EQUIPMENT
FORMAT FLASH CARD CABLE (1660SM/1670SM)
DEBUG CABLE (EC) 1626LM EQUIPMENT1 Straight cable specific EIA 568 A
Use UTP Gat 5 cable with RJ45 not shielded connectors on both side
EIA 568
<+—> Pin] WHITE/green
<+—> Pin? GREEN
Pin3 WHITBorange <> Pin3 WHITE/orange
Pin BLUE +—> Pind BLUE
Pin WHITE/blue = ——» Pins WHITE/blue
Pin 6 ORANGE +—> Pin6 ORANGE
Pin? WHTIE/brown = 4» in7 wn
Pin 8 BROWN, +—_Ping BROWN,2 Crossover cable specific EIA 568 B
Use UTP Cat 5 cable with RU45 not shielded connectors on both side
EIA 568 B
Pin1 WHITE/green = <> Pin WAITB/orange
Pin? GREEN <—> Pin? ORANGE
Pin3 WHITE/orange = <—> Pin3 WHITE/ercen
Ping BLUE <—> Pind BLUE
Pins WHITEbue = 4 Pin WHITE/blue
Pin 6 ORANGE +—> Pin6 GREEN
Pin7 WHITE/brown = <—> Pin 7 WHITE/orown
Pin 8 BROWN <—> Ping BROWN