This document provides maintenance and troubleshooting guidance for fiber optic splicing equipment. It recommends using a cotton swab moistened with alcohol daily to clean specific components. It also lists potential issues with actual splice loss, poor heat shrink performance, and common error messages, and recommends checking splice mode settings, replacing electrodes, performing arc calibration, adjusting heating settings and modes, and consulting the quick reference guide for details.
This document provides maintenance and troubleshooting guidance for fiber optic splicing equipment. It recommends using a cotton swab moistened with alcohol daily to clean specific components. It also lists potential issues with actual splice loss, poor heat shrink performance, and common error messages, and recommends checking splice mode settings, replacing electrodes, performing arc calibration, adjusting heating settings and modes, and consulting the quick reference guide for details.
This document provides maintenance and troubleshooting guidance for fiber optic splicing equipment. It recommends using a cotton swab moistened with alcohol daily to clean specific components. It also lists potential issues with actual splice loss, poor heat shrink performance, and common error messages, and recommends checking splice mode settings, replacing electrodes, performing arc calibration, adjusting heating settings and modes, and consulting the quick reference guide for details.
Please use thin cotton swab moistened with alcohol to
clean the following: Daily ・V-groove, fiber-clamp, lens Maintenance ・Cleaver, cleaver blade、rubber pad. ※ Please refer to the “Quick Reference Guide” for more details.
・Is the correct Splice Mode selected?
→Please select the correct splice mode for best splicing High performance. Actual Splice ・Is the electrode worn off or broken? Loss →Please change the electrodes. ※ Please refer to the “Quick Reference Guide” for more details. ・Not able to splice in high altitude condition? →Please perform arc calibration before splicing.
・Is the correct Heating Mode selected?
Poor Heat →Please select the correct heating mode for the type of Shrink fiber spliced. ・Protection sleeve do not shrink properly? Performance →Please adjust the heating time.
“Too long fiber”, “Too Dusty Fiber”, “ZL/ZR Motor Overrun”,
Common “Large Cleave Angle”, “Cleave Shape NG”. ※ Please refer to the “Quick Reference Guide” for more error details on the errors and recommended solutions. messages