We had a conference call with Konstantin and Dmitry, today morning regarding the queries for the SRT &
DRT.
I would like to discuss the synopsis with you.
Presently this machine is not as per the specification of Indian Railways, as the sensitivity settings for
the IR calibration block is not possible.
The software needs to be updated as per IR specification. Presently this is for Russian Railways.
We need to reshuffle the display of the probes in the B-scan mode as:
1st: 0 degree,
2nd: Center 70 probes (Forward & Reverse),
3rd: Gauge 70 probes (Forward & Reverse),
4th: Field 70 probes (Forward & Reverse).
Then we can have all the others, but preferably nothing else is required.
During the booting of the machine, the logo of TVEMA is flashing but as already discussed this
should be either blank or we need to change this to 'SCAT-2 Single Rail Tester', without the brand.
We have not received the specification of the probes (E.g. Frequency, Diameter, Thickness, Crystal
etc...)
For the DRT, we need the probe set also (as above) with the display unit of the equipment.