Air Concitioner Service Manual © Error list Failure Type LED Code Digital LEDCode Indoor and outdoor communication falure | RUN. TIMER-both winking £0 Outdoor communication failure RUN, TIMER both winking EC Indoor room temperature sensor (RT) RUN Et Indoor coil temperature sensor (IPT) RUN2tmessBs E2 Outdoor coil temperature sensor (OPT) RUN-tmes és &3 System abnormity RUN-Atmes 8s 4 Model configuration wrong RUNStimes 8s &5 Indoor fan motor fault RUNStmes és 6 Outdoor temperature sensor RUN Ttimes/Bs e7 Exhaust temp. sensor RUNStimes és 8 IPM dive and module faut RUNtimes 8s 9 ‘Outdoor fan motor fault (DC motor) RUN-Otmesiés EF Current sensor faut RUN—*itimes fs EA EEPROM fault RUN-12times es EE Temp. switch fault (on top of the RUN-13times/es EP compressor) Voltage sensor fault RUN-t4iimes es EU Air fiter duty ot «Protection display code lst: Protection Type Function Indicator flash) | DigitalLEDCode ervoiage Hower voltage protection | RUN: Blink; TIMER: 1 blink 8 seo Pt wercurrent protection RUN: Blink; TIMER: 2 blink 6 see P2 [Exhaust over temperature protection | RUN: Blink; TIMER: 4 blink /6 sec Pa [To0 cool protection in cooling mode _| RUN Bright; TIMER’ 5 bink 8 sec Ps verheat protection in cooling mode _| RUN’ Bright, TIMER: 6 bink 8 sec P6 werheat protection nhheating mode | RUN: Bright, TIMER: 7 biink /8 sec P7 Tess lomperatine protection RUN: Bright; TIMER: 8 blink /8 sec PB Drive protection (software control) | RUN: Blink; TIMER: 9 blink /8 sec Pe Module protection (hardware control) | RUN: Blink; TIMER: 10 blink /8 sec PO © Outdoor failure display There is a LED on outdoor power board, it blinks 1s ON and 1s OFF while compressor standby and it always light (ON) while compressor running; If there is failure happened on ODU, The indicator (LED) alerts the fault in a cycle as such that its bright for 0.5 seconds, dark for 0.5 seconds, blinks *n’ times. and then dark for 3 seconds. For details as table below: Air Conditioner Service Manual Display on outdoor power source board blink time (n) Failure 7 Pit prceaton 7 ver vlog Rawervaage 3 overt 4 Exhaust ove Temperature potecion 5 Outdoor col over temperature prtecion @ Brive ful and protection (Vi VPA) 7 ammunition faut wih indoor nit 8 (Compressor overheat fault (compressor top switch) @ Shr eul/oper-reul ful of eudoor temperature Sensor go letter open in cekicor Peet exanger eps 7 Shortcut opera ful of exhaust ionperare enaor 12 Watage sensor fault 13 Curent sensor faut 4PM 15 Commungaion ful bebveen power source board and IP 16 No feedback from DC fan motor(outdoor unit) 17 Petros state 10

You might also like