Professional Documents
Culture Documents
Overview
Styles of Fittings
Standard Specifications
Special Features
Installation
Maintenance
Seals
Drawings
Raised Face Flangnek 2"-14" Class 150-900
Dimensions
Flangnek Raised Face Class 150, 300, 600, 900,
1500, 2500
Parts
2"-14" Class 150-900
When Paul Daniel developed his first orifice fitting in the early
1930's, he knew that he had a good idea and a sound
design. But he could not have realized that 60-plus years
later there would be hundreds of thousands of Senior Orifice
Fittings in use worldwide and that Daniel Industries would be
the world leader in the manufacture of orifice measurement
equipment.
The many outstanding features found only in Daniel Senior Fittings are the result of many years of
experience and research into flow measurement. In fact, the term "Senior" applied to an orifice fitting
specifically denotes the Daniel designed Dual-chamber Orifice Fitting. This fitting provides a fast, safe and
extremely simple method of changing orifice plates under pressure without interrupting the flow and
eliminates costly by-passes, valves and other fittings required with conventional orifice flange installations.
Daniel's most popular Senior Orifice Fitting, the "Flangnek," has a
weldneck inlet and a flanged outlet. Daniel fittings meet or exceed
API Chapter 14, Section 3, Part 2 (14.3/AGA 3) and ASME code
requirements. They are usually furnished with Daniel Meter Tubes,
which are designed and manufactured under a controlled
fabrication environment to assure that customer/code specifications
are met.
Note: All products and components are subject to change without notice in a continuing effort of product
improvement.
Standard Specifications
METER TAPS: All Daniel Orifice Fittings are provided with two sets of "Flange Taps," located in accordance
with latest ANSI/API 2530 (AGA #3) recommendations.
FLANGE TAP SPECIFICATIONS: Flange tap meter connections are 1/2" NPT. Internal tap hole sizes follow
latest ANSI/API 2530 (AGA #3) recommendations. Internal edges of tap holes are free from burrs and square
edged.
LINE BORE TOLERANCES: 2-inch and 3-inch sizes, plus or minus .003"; 4-, 6-, 8-, and 10-inch sizes, plus or
minus .004"; 12-inch and larger sizes, plus or minus .005". Unless otherwise specified, all fittings are furnished
with standard internal line bore as listed in dimensional tables.
OPERATING SHAFTS: On sizes 2-inch to 14-inch inclusive, single operating shafts are standard on left side of
fitting when looking downstream. On sizes 16-inch and larger, operating shafts on both sides of fitting are
standard.
The Senior Orifice Fitting is composed of two independent compartments separated by a hardened stainless
steel slide valve.
Side sectional view below left shows the slide valve in closed position and orifice plate concentric in line of flow.
Slide valve cannot be closed unless orifice is concentric to bore of fitting.
Photo, below right, shows the Daniel top closure in opened position with plate carrier in place for change or
inspection of orifice plate. Only a few turns of the speed wrench are required to loosen screws to remove or
replace clamping and sealing bars. Set screws always remain in clamping bar. This feature adds greatly to
speed and ease of operation.
Plate carrier is raised and lowered by double rack and pinion mechanism with power applied through speed
wrench. This method provides the quickest means of operation with the least amount of effort and assures
positive control of plate carrier at all times.
All parts, including the essential slide valve assembly, may be replaced or repaired without removing fitting from
line.
TEMPERATURE UNITS: Standard trim fittings Class 150-900 are suitable for -20 to +450ºF service. Class
1500 and 2500 are suitable for service in -20 to +275ºF. However, the Orifice Plate Seal used may limit the
service temperatures. See document entitled "Orifice Plate Sealing Units" for details. Special trims and seals
are available for higher or lower temperature service. Please consult factory.
INDICATOR PLATE: Standard on all Senior Orifice Fittings, this plate clearly shows the direction of the open
and closed position of the Slide Valve.
OPERATING WRENCH: A speed wrench is provided with each fitting for quick operation of the shaft and
pinions.
HYDROSTATIC TESTING: All Daniel Senior Orifice Fittings are hydrostatically tested in accordance with ANSI
B16.34.
PLATE ALIGNMENT: The plate carriers in all Senior fittings are centered using a fixed three point positioning
system. This assures concentricity within the fitting in accordance with the latest ANSI/API 2530 (A.G.A. Report
#3).
...........................
Orifice Plate Sealing Units
The Daniel Dual Seal is the most simple and practical orifice plate
sealing device for normal flowing streams. It is precision molded
from 70-80 shore nitrile synthetic rubber** and provides four
rubber-to-metal sealing surfaces 360º around the plate. The units
positively seal against both outer faces of the plate and against
both seats of the orifice fitting to prevent leakage.
The Snap Seal Ring unit consists of two symmetrical metal rings,
each one having an O-ring on both sides for a positive seal on the
plate side and the fitting side of the ring. These rings center and
secure the orifice plate between them. The assembled unit provides
a full 360º rubber-to-metal seal around both sides, even in the
absence of any pressure differential. No special tools are required
for assembly or disassembly.
The two-piece unit consists of an inlet ring which fits around the
plate outer diameter, and a downstream ring fitted with metal clips
for assembling the unit. A special lip on this ring plus an annular
groove* provide compression to effectively seal off the plate. The
"TSC" unit can be assembled or taken apart by hand and is
interchangeable in 1 1/2" to 10" sizes with Daniel "DSC" and "MSC"
seal units.
...........................
Special Features
ORIFICE PLATE SEALING UNITS, designed and patented by Daniel, give positive seal between orifice plate
and body seats. Available for a variety of services.
PLATE CARRIER protects orifice plate at all times while inserting or removing from fitting.
TOP OUTSIDE GUIDE BRACKETS with pinion and roller assembly are standard equipment on 18-inch and
larger Senior Fittings. Orifice plates can be inspected or changed without disengaging plate carrier from
pinions.
INDICATOR PLATE clearly shows the position of the slide valve within the fitting.
TEFLON SHAFT PACKING AND CENTERING RINGS are standard equipment on all Daniel Senior Orifice
Fittings in all sizes and ratings.
FITTINGS up to and including 12" line size can operate in a vertical up flow condition or positioned in horizontal
flow for side opening.
ALL DANIEL SENIOR ORIFICE FITTINGS are designed and manufactured to meet latest ANSI/API/AGA
recommendations, and in strict accordance with latest A.S.T.M. specifications.
The drawing above shows in detail the extra-heavy construction of the wall sections and essential parts on the
Class 1500 Senior Orifice Fitting.
NOTE: Body/Top Gasket--peroxide cured nitrile O-ring for Class 1500 fittings. Male and female gasket joint with
Parker seal gaskets for Class 2500 Orifice Fitting.
"TS" (All-Teflon) Orifice Plate Sealing Unit is standard in Class 900, 1500, and 2500 fittings.
Class 400 or higher, flanges are manufactured with close-tolerance, square-shouldered, large male
flange-facing on fitting and large female flange-facing on meter tube to assure proper internal alignment. Flange
gaskets are precision-cut so that under compression they will not extend into internal bore of fitting. Refer to
engineering drawing above.
In Daniel Senior Orifice Fittings, the valve seat (Part No. 18) is a part of the upper chamber. The valve strip
(Part No. 3) moves underneath this seat, thus utilizing line pressure to effect a positive seal. The valve strip is
maintained in "floating" position by minimum spring pressure.
Before slide valve is opened, it is lubricated through grease gun, No. 23. Pressure is then equalized throughout
the entire fitting by operation of the equalizer valve, No. 1. Equalized pressure on both sides of the valve strip
allows slide valve to move freely without wear. Valve seat and valve strip are ground for tight shut-off and are
easily removable for grinding if required.
Installation
1. Remove all foreign matter such as dirt, sediment or scale from fitting surfaces, connections and internal
cavities which may have collected between factory inspection and delivery. Gasket the line flanges and
install or weld the fitting in line, making sure flow arrow cast on body corresponds to flow direction.
2. Install Bleeder Valve (Part No. 10B) and Grease Gun (Part No. 23) to connections provided on fitting
which are shipped separately.
3. The standard Senior® Orifice Fitting is assembled with the gear shafts located on the left side of the
fittings as you are facing the fitting looking downstream. For this standard arrangement, rotate the Slide
Valve Gear Shaft (lower upstream shaft) clockwise until it stops to open the Slide Valve. Place Slide
Valve Indicator Plate (shipped separately) stamped "LH" on the Slide Valve Gear Shaft with the word
OPEN at the 12 o'clock position. Tighten the set screw (shipped separately) to fix the Plate on the Shaft.
Use two drive screws (shipped separately) to install the Indicator Pointer on the fitting body so that it
points to the world OPEN on the Plate. The Senior Orifice Fitting may have the optional "reversed
shafts" arrangement where the gear shafts are located on the right side of the fitting as you are facing
the fitting looking downstream. In that case, rotate the Slide Valve Gear Shaft (lower upstream shaft)
counterclockwise until it stops to open the Slide Valve. Place the Slide Valve Indicator Plate stamped
"RH" on the Slide Valve Gear Shaft with the word OPEN at the 12 o'clock position. Tighten the set screw
to fix the Plate on the Shaft. Use two drive screws to install the Indicator Pointer on the fitting body so
that it points to the word OPEN on the plate.
4. When fitting is shipped, the Plate Carrier (Part No. 8DM) is enclosed inside the fitting and the Orifice
Plate is packaged separately.
5. After installation, remove Drain Plugs (Part No. 30). Check for any foreign matter that may have become
trapped in fitting cavities. Install full-opening valves for blow-down operation.
Removing/Replacing Orifice Plate
TO REMOVE ORIFICE PLATE TO REPLACE ORIFICE PLATE
1. Open Equalizer Valve 1. Close Bleeder Valve (No.
(No. 1) Max two turns 10B)
only 2. Rotate Upper Plate Carrier
2. Open Slide Valve (No. Gear Shaft (No. 7) slowly
5) until Plate Carrier is clear of
3. Rotate Lower Plate Sealing Bar and Gasket
Carrier Gear Shaft (No. level. Do not lower Plate
6) Carrier onto Slide Valve.
4. Rotate Upper Plate 3. Replace Sealing Bar Gasket
Carrier Gear Shaft (No. (No. 9A), Sealing Bar (No.
7) 9), and Clamping Bar (No.
12).
5. Close Slide Valve (No.
5) 4. Tighten Clamping Bar
Screws (No. 11)
6. Close Equalizer Valve
(No. 1) 5. Open Equalizer Valve (No.
1)
7. Open Bleeder Valve
(No. 10B)* 6. Open Slide Valve (No. 5)
8. Lubricate Thru Grease 7. Rotate Upper Plate Carrier
Gun (No. 23) Gear Shaft (No. 7)
9. Loosen Clamping Bar 8. Rotate Lower Plate Carrier
Screws (No. 11); DO Gear Shaft (No. 6)
NOT Remove Clamping 9. Close Slide Valve (No. 5)
Bar (No. 12) 10. Close Equalizer Valve (No.
10. Rotate Upper Plate 1)
Carrier Gear Shaft (No. 11. Open Bleeder Valve (No.
7) to free Sealing Bar 10B)*
(No. 9) and Sealing Bar
Gasket (No. 9A) 12. Lubricate Thru Grease Gun
(No. 23)
11. Remove Clamping Bar
(No. 12), Sealing Bar 13. Close Bleeder Valve (No.
(No. 9), and Sealing Bar 10B)
Gasket (No. 9A)
*When venting upper chamber through bleeder valve (#10B), direct fluid to a safe area using the threaded connection
at the valve discharge point.
CAUTION: Daniel Senior Orifice Fittings are operated under pressurized line conditions. Proper precautions must be
exercised to protect personnel. Always read and follow OPERATING instructions and avoid placing any part of the
body in front of the top opening when the clamping bar is removed.
Representative Operational Sequence
OPERATION OF A DANIEL SENIOR ORIFICE FITTING
The valve seat and the valve strip are field replaceable or repairable (re-lapping) without removing the
fitting from the line, reducing down-time.
Caution: This operational sequence is representational only and it not intended for use as a field guide
to operations. Always read and follow the detailed operating instructions provided with each fitting
before attempting to operate.
Maintenance
1. It is recommended that all Senior Orifice Fittings be operated once every thirty days. Slide valve should
be opened and closed and lubricant should be applied through grease gun.
2. If plate inspection is not required, rotate operating shafts anyway.
3. In conditions where foreign matter accumulates, blow-down valves (as per installation instructions, Step
No. 5) should be used to clear dirt from fittings as often as required. Plate Carrier should always be
raised into upper chamber before blowing or cleaning through blow-down valves.
4. When pigging the line, a pigging ring is recommended to prevent dirt from being forced into the plate
carrier cavity.
5. Following the pigging operation, the blow-down valve(s) should be opened to clear out any accumulation
of dirt which may have been forced into the plate carrier cavity.
Dimensional Diagrams
FLANGNEK - RAISED FACE
2" Thru 14"
Class 150-900
Sizes 12" and 14" up to Class 900 contain "DVS" Seal Vulcanized to plate.
ANSI 300 Class
FLANGNEK - RAISED FACE
Sizes 12" and 14" up to Class 900 contain "DVS" Seal Vulcanized to plate.
ANSI 600 Class
FLANGNEK - RAISED FACE
Sizes 12" and 14" up to Class 900 contain "DVS" Seal Vulcanized to plate.
ANSI 900 Class
FLANGNEK - RAISED FACE
Sizes 12" and 14" up to Class 900 contain "DVS" Seal Vulcanized to plate.
ANSI 900 Class
FLANGNEK - RING JOINT
Sizes 12" and 14" up to Class 900 contain "DVS" Seal Vulcanized to plate.
ANSI 300 Class
FLANGED - RAISED FACE
Sizes 12" and 14" up to Class 900 contain "DVS" Seal Vulcanized to plate.
ANSI 600 Class
FLANGED - RAISED FACE
Sizes 12" and 14" up to Class 900 contain "DVS" Seal Vulcanized to plate.
ANSI 900 Class
FLANGED - RAISED FACE
Sizes 12" and 14" up to Class 900 contain "DVS" Seal Vulcanized to plate.
ANSI 900 Class
FLANGED - RING JOINT
Sizes 12" and 14" up to Class 900 contain "DVS" Seal Vulcanized to plate.
ANSI 900 Class
WELDING NECK
ALL PARTS ON DANIEL SENIOR ORIFICE FITTING MAY BE REPLACED OR REPAIRED WITHOUT REMOVING FITTING FROM THE LINE.
PARTS AND MATERIALS NUMBER REQUIRED
SIZE
Part No. DESCRIPTION MATERIAL 2" 3" 4" 6" 8" 10" 12" 14"
1* Equalizer Valve
(Complete)
1G* Stem 316 Stainless 1 1 1 1 1 1 1 1
Steel
1H* Packing Nut CS (CP) 1 1 1 1 1 1 1 1
1D* Ball Chrome-Steel 1 1 1 1 1 1 1 1
1K* Packing Washer 316 Stainless 1 1 1 1 1 1 1 1
Steel
1J* Packing Ring Teflon 2 2 2 2 2 2 2 2
2* Operating Ductile Iron 1 1 1 1 1 1 1 1
Wrench
3 Slide Valve Strip Type 410 1 1 1 1 1 1 1 1
Stainless Steel
4 Body Cast Carbon 1 1 1 1 1 1 1 1
Steel
(Class 150, 300,
600, 900)
5 Slide Valve Gear CS (CP) 1 1 1 1 1 1 1 1
Shaft
5A* Slide Valve Cast Aluminum 1 1 1 1 1 1 1 1
Indicator Plate
5B* Slide Valve Stainless Steel 1 1 1 1 1 1 1 1
Indicator Pointer
6 Lower Plate CS (CP) 1 1 1 1 1 1 1 1
Carrier Gear
Shaft
7 Upper Plate CS (CP) 1 1 1 1 1 1 1 1
Carrier Gear
Shaft
8DM Plate Carrier CS (CP) 1 1 1 1 1
316 SS 1 1 1
8E Orifice Plate Nitrile 1 1 1 1 1 1 --- ---
Sealing Unit (Removeable)
Class 150-600 12" up--Nitrile 1 1
Bonded to Both
Sides of Orifice
Plate
8TS Orifice Plate Teflon 1 1 1 1 1 1 1 1
Sealing Unit
(Complete):
Class 150-2500
Alternate Seals
Avail.
See
Catalog--#500
9 Sealing Bar CS (CP) 1 1 1 1 1 1 1 1
9A Sealing Bar Graphite 1 1 1 1 1 1 1 1
Gasket Asbestos
10B* (1) Bleeder Valve
(Complete):
10C* Body CS (CP) 1 1 1 1 1 1 1 1
10D* Needle 316 Stainless 1 1 1 1 1 1 1 1
Steel
10E* "O" Ring Synthetic Rubber 1 1 1 1 1 1 1 1
10G* Set Screw Alloy Steel 1 1 1 1 1 1 1 1
11* Clamping Bar Alloy Steel CL 4 4 5 6 7 8 10 11
Screw 150 to 600
Alloy Steel CL 4 4 5 6 8 8 10 22
900
12 Clamping Bar CS (CP) 1 1 1 1 1 1 1 1
13 Orifice Plate Type 304 or 316 1 1 1 1 1 1 1 1
Stainless Steel
14 Top Cast Carbon 1 1 1 1 1 1 1 1
Steel
(Class 150, 300,
600, 900)
15* Slide Valve 316 Stainless 4 4 4 6 6 6 7 8
Springs Steel
16* Slide Valve 316 Stainless 2 2 2 2 2 2 2 2
Carrier Guide Steel
17 Slide Valve Carbon Steel 1 1 1 1 1 1 1 1
Carrier
17A* Slide Valve Carbon Steel 2 2 2 2 2 2 2 2
Carrier Stop Pin (CP)
18 Slide Valve Seat Alloy Iron 1 1 1 1 1 1** 1** 1**
18A Slide Valve Seat Graphite 1 1 1 1 1 1 1 1
& Top Gskt Asbestos
18B* Slide Valve Seat Alloy Steel 8 10 11 14 16 18 20 24
Screw Phosphate
Coated
19 Bearing Plug CS (CP) 1 1 1 1 1 1 1 1
(Upper)
20* Stuffing Box CS (CP) 1 1 1 1 1 1 1 1
(Upper)
21 Stuffing Box CS (CP) 2 2 2 2 2 2 2 2
(Lower)
22 Bearing Plug CS (CP) 2 2 2 2 2 2 2 2
(Lower)
22A* Bearing Plug & Stainless Steel 6 6 6 6 6 6 6 6
Stuffing Box
Gasket
23* Grease Gun CS (CP) 1 1 1 1 1 1 1 1
(Complete)
23A* Grease Gun CS (CP) 1 1 1 1 1 1 1 1
Stem
23B* Grease Gun CS (CP) 1 1 1 1 1 1 1 1
Body
24* Grease Seal 316 Stainless 1 1 1 1 1 1 1 1
Double Ball Steel with
Check Valve Chrome-Steel
Balls
25* Packing Nut CS (CP) 3 3 3 3 3 3 3 3
25A* Packing Ring Teflon Varies with Size of Fitting
and Pressure Rating
25B* Bearing Plug and Teflon 15 15 15 15 15 15 15 15
Stuffing Box
Centering Ring
26* Stuffing Box 316 Stainless 3 3 3 3 3 3 3 3
Gland Steel
28A* Packing Bushing 316 Stainless 3 3 3 3 3 3 3 3
and Retainer Steel
30* Drain Valve Plug CS (CP) 2 2 2 2 2 2 2 2
31* 1/2" NPT Plug CS (Chemically 4 4 4 4 4 4 4 4
for Pressure Treated)
Meter Tap
32 Hex. Nut CS -- Class 150 14 15 15 18 19 22 22 24
to 600 Incl.
CS -- Class 900 14 15 15 18 20 22 22 24
33 Stud Alloy Steel CL 14 15 15 18 19 22 22 24
150 to 600 Incl.
Alloy Steel CL 14 15 15 18 20 22 22 24
900
34* Bearing Plug CS (CP) 1 1 1 1 1 1 1 1
Body (Upper)
35* Bearing Plug CS (CP) 2 2 2 2 2 2 2 2
Body (Lower)
36* Stuffing Box CS (CP) 1 1 1 1 1 1 1 1
Body (Upper)
37* Stuffing Box CS (CP) 2 2 2 2 2 2 2 2
Body (Lower)
38 Bearing Plug CS (CP) 1 1 1 1 1 1 1 1
Sleeve (Upper)
39 Bearing Plug CS (CP) 2 2 2 2 2 2 2 2
Sleeve (Lower)
40 Stuffing Box CS (CP) 1 1 1 1 1 1 1 1
Sleeve (Upper)
41 Stuffing Box CS (CP) 2 2 2 2 2 2 2 2
Sleeve (Lower)
25* Packing Nut CS (CP) 3 3 3 3 3 3 3 3
25A* Packing Ring Teflon 3/8" Thick 9 9 9 9 9 9 9 9
25B* Centering Ring Teflon 3/16" 9 9 9 9 9 9 9 9
Thick
26* Stuffing Box 316 S.S. 3 3 3 3 3 3 3 3
Gland
NOTE: Available in other materials upon specification. CS (Carbon Steel), CP (Cadmium Plated)
Various Part Materials are changed for "AASG" Trim Fittings
ALL PARTS ON DANIEL SENIOR ORIFICE FITTING MAY BE REPLACED OR REPAIRED WITHOUT REMOVING FITTING FROM THE LINE.
PARTS AND MATERIALS NUMBER REQUIRED
SIZE
Part No. DESCRIPTION MATERIAL 2" 3" 4" 6" 8" 10" 12"
1* Equalizer Valve
(Complete)
1G* Stem 316 Stainless Steel 1 1 1 1 1 1 1
1H* Packing Nut CS (CP) 1 1 1 1 1 1 1
1D* Ball Chrome-Steel 1 1 1 1 1 1 1
1K* Packing Washer 316 Stainless Steel 1 1 1 1 1 1 1
1J* Packing Ring Teflon 2 2 2 2 2 2 2
2* Operating Wrench Ductile Iron 1 1 1 1 1 1 1
3 Slide Valve Strip Stainless Steel 1 1 1 1 1 1 1
4 Body Cast Carbon Steel 1 1 1 1 1 1 1
5 Slide Valve Gear Shaft CS (CP) 1 1 1 1 1 1 1
5A* Slide Valve Indicator Plate Cast Aluminum 1 1 1 1 1 1 1
5B* Slide Valve Indicator Stainless Steel 1 1 1 1 1 1 1
Pointer
6 Lower Plate Carrier Gear CS (CP) 1 1 1 1 1 1 1
Shaft
7 Upper Plate Carrier Gear CS (CP) 1 1 1 1 1 1 1
Shaft
8DM Plate Carrier CL 1500 - 316 Stainless 1 1 1
Steel
CL 1500 - CS (CP) 1 1 1 1
CS 2500 - CS (CP) 1 1 1 1
8TS Orifice Plate Sealing Unit Teflon 1 1 1 1 1 1 1
(Without Orifice Plate)
9HP Sealing Bar CS (CP) 1 1 1 1 1 1 1
9A Sealing Bar Gasket Synthetic Composition 1 1
9CF "Compoflex" Sealing Bar Synthetic Composition 1 1 1 1 1
Gasket
10B* (1) Bleeder Valve (Complete): CS (CP)
10C* Body CS (CP) 1 1 1 1 1 1 1
10D* Needle 316 Stainless Steel 1 1 1 1 1 1 1
10E* "O" Ring Synthetic Rubber 1 1 1 1 1 1 1
10G* Set Screw Alloy Steel 1 1 1 1 1 1 1
11* Clamping Bar Screw Alloy Steel -- CL 1500 (CP) 10 10 12 14 16 16 20
Alloy Steel -- CL 2500 (CP) 10 10 12 14
12HP Clamping Bar CS (CP) 1 1 1 1 1 1 1
13 Orifice Plate Type 304 or 316 Stainless 1 1 1 1 1 1 1
Steel
14 Top Cast Carbon Steel 1 1 1 1 1 1 1
14CF Body-Top "O" Ring Special Compound 1 1 1 1 1
Synthetic Rubber CL 1500
14CF-C Body-Top Gasket Parker Seal Synthetic 1 1 1 1
(Male-Female Joint) Rubber Gasket CL 2500
Not Illustrated
15* Slide Valve Springs 316 Stainless Steel 4 4 4 6 6 6 7
16* Slide Valve Carrier Guide 316 Stainless Steel 2 2 2 2 2 2 2
17 Slide Valve Carrier Carbon Steel 1 1 1 1 1 1 1
17A* Slide Valve Carrier Stop Carbon Steel (CP) 2 2 2 2 2 2 2
Pin
18 Slide Valve Seat Stainless Steel 1 1 1 1 1 1 1
18A Slide Valve Seat Gasket Synthetic Comp. - CL 1500 1 1 1 1 1
Synthetic Comp. - CL 2500 1 1 1 1
Slide Valve Seat/Top Synthetic Comp. - CL 1500 1 1
Gasket (Not Illustrated)
18B* Slide Valve Seat Screw Alloy Steel CL 1500 Phos 8 10 11 14 16 18 20
Coat
Alloy Steel CL 2500 Phos 10 10 11 14
Coat
19 Bearing Plug (Upper) CS CL 1500 (CP) 1 1 1 1 1 1 1
19HP Bearing Plug (Upper) CS CL 2500 (CP) 1 1 1 1
20 Stuffing Box (Upper) CS CL 1500 (CP) 1 1 1 1 1 1 1
20HP Stuffing Box (Upper) CS CL 2500 (CP) 1 1 1 1
21 Stuffing Box (Lower) CS CL 1500 (CP) 2 2 2 2 2 2 2
21HP Stuffing Box (Lower) CS CL 2500 (CP) 2 2 2 2
22 Bearing Plug (Lower) CS CL 1500 (CP) 2 2 2 2 2 2 2
22HP Bearing Plug (Lower) CS CL 2500 (CP) 2 2 2 2
22A* Bearing Plug & Stuffing 316 Stainless Steel CL 6 6 6 6 6 6 6
Box Gasket 1500
22A-HP* Bearing Plug & Stuffing 316 Stainless Steel CL 6 6 6 6
Box Gasket 2500
22B* Bearing Plug & Stuffing Synthetic Rubber CL 2500 6 6 6 6
Box O-Ring Seal
23* Grease Gun (Complete) CS (CP) 1 1 1 1 1 1 1
24* Grease Seal Double Ball 316 Stainless Steel with 1 1 1 1 1 1 1
Check Valve Chrome-Steel Balls
25* Packing Nut CS CL 1500 (CP) 3 3 3 3 3 3 3
25HP* Packing Nut CS CL 2500 (CP) 3 3 3 3
25A* Packing Ring Teflon CL 1500 Varies with Size of Fitting
25A-HP* Packing Ring Teflon CL 2500 and Pressure Rating
25B* Bearing Plug Centering Teflon CL 1500 & 2500 9 9 9 9 9 9 9
Ring
25B* Stuffing Box Centering Teflon CL 1500 6 6 6 6 6 6 6
Ring
25B-HP* Stuffing Box Centering Teflon CL 2500 6 6 6 6 6 6 6
Ring
26* Stuffing Box Gland 316 Stainless Steel CL 3 3 3 3 3 3 3
1500
26B* External Stuffing Box 316 Stainless Steel CL 3 3 3 3
Gland with "O" Ring 2500
Groove
26E* Internal Stuffing Box Gland 316 Stainless Steel CL 3 3 3 3
with "O" Ring Groove 2500
26C* "O" Ring Synthetic Rubber CL 2500 3 3 3 3
26D* "O" Ring Synthetic Rubber CL 2500 6 6 6 6
28A* Packing Bushing and Stainless Steel CL 1500 3 3 3 3 3 3 3
Retainer
30* Drain Valve Plug CS 2 2 2 2 2 2 2
31* 1/2" NPT Plug for CS 4 4 4 4 4 4 4
Pressure Meter Tap
32 Hex. Nut CS -- Class 1500 14 14 16 18 18 22 22
CS -- Class 2500 16 16 16 18
33 Stud Alloy Steel -- CL 1500 14 14 16 18 18 22 22
Alloy Steel -- CL 2500 16 16 16 18
POST JULY 1986 CL 1500
STUFFING BOX AND BEARING PLUG:
34* Bearing Plug Body (Upper) CS (CP) 1 1 1 1 1 1 1
35* Bearing Plug Body (Lower) CS (CP) 2 2 2 2 2 2 2
36* Stuffing Box Body (Upper) CS (CP) 1 1 1 1 1 1 1
37* Stuffing Box Body (Lower) CS (CP) 2 2 2 2 2 2 2
38 Bearing Plug Sleeve CS (CP) 1 1 1 1 1 1 1
(Upper)
39 Bearing Plug Sleeve CS (CP) 2 2 2 2 2 2 2
(Lower)
40 Stuffing Box Sleeve CS (CP) 1 1 1 1 1 1 1
(Upper)
41 Stuffing Box Sleeve CS (CP) 2 2 2 2 2 2 2
(Lower)
25* Packing Nut CS (CP) 3 3 3 3 3 3 3
25A* Packing Ring Teflon 3/8" Thick 9 9 9 9 9 9 9
25B* Centering Ring Teflon 3/16" Thick 9 9 9 9 9 9 9
26* Packing Gland 316 S.S. 3 3 3 3 3 3 3