SEL aD Ad aU
made up of three valves;
-3/2 way valve(as AND gate)
@ -3/2 way double pilot valve
-OR gate
X : input (from signalling element)
A : output (to a signalling element)
: compressed air supply
to set mug Mula (Gilevnine le to A)
Ta ennaincom aia ilyMODE OF OPERATION OF MODULE TAA
“The memory is set by a signal from the preceding
module. This causes a signal to be sent to A, which
activates the final control element and thus
actuator.
~The actuator signals via a sensor (signal element)
at input X that a step has been completed.
*The signal at input X reverses the AND gate,
which sets the memory of the following module via
Yn+1 (pressure is supplied to the AND gate via P)MODE OF OPERATION OF MODULE TAA
(cont.)
~Simultaneously to the signal at A, which comes
from the memory, this signal is passed back via Zn
and the OR gate to the previous memory and resets
ie
~The OR gate enables the sequencer to resume the
initial position (signals at output A and Yn+1) in any
situation (2.g. emergency stop)