You are on page 1of 13
SEL aD Ad aU made up of three valves; -3/2 way valve(as AND gate) @ -3/2 way double pilot valve -OR gate X : input (from signalling element) A : output (to a signalling element) : compressed air supply to set mug Mula (Gilevnine le to A) Ta ennaincom aia ily MODE OF OPERATION OF MODULE TAA “The memory is set by a signal from the preceding module. This causes a signal to be sent to A, which activates the final control element and thus actuator. ~The actuator signals via a sensor (signal element) at input X that a step has been completed. *The signal at input X reverses the AND gate, which sets the memory of the following module via Yn+1 (pressure is supplied to the AND gate via P) MODE OF OPERATION OF MODULE TAA (cont.) ~Simultaneously to the signal at A, which comes from the memory, this signal is passed back via Zn and the OR gate to the previous memory and resets ie ~The OR gate enables the sequencer to resume the initial position (signals at output A and Yn+1) in any situation (2.g. emergency stop)