110213/01

Structural Seismic Analysis of Industrial Rack Revision: 00


Page 1 of 1

TEST SUMMARY
Sr Description Remarks/Comments
1 Customer : DLCustom

2 Product Tested : Industrial PC Rack

3 Seismic Spectrum Tested for : Bellcore Zone 4 Spectrum

Sr Freq(Hz) G(mm/sec2)
1 0.3 1962
2 0.6 19620
3 2 49050
4 5 49050
5 15 15696
6 50 15696
3 Method Used for Test : Computational Method (Finite FEA Modal and
Element Analysis) Seismic(Spectrum) analysis
were done for SPRS(Single
Point Response System)

4 Maximum Equivalent Stress Found(MPa): 126 MPa ACCEPTABLE

5 Minimum Margin of Safety of System : 0.4 ACCEPTABLE

00 11/02/2013 Seismic Qualification Bhaumik Dave

FEA Simulation
Revision Date Purpose Reviewed By Approved By
By