» SNC-LAVALIN ‘Surge and Lightning Protection Study of Date:17 February 201 WANETA EXPANSION PROJECT Page 3 of 36 Document No. 020655-0000-47E3-001 Revision No.: 0 ao PN OTaEVeas TABLE OF CONTENTS Introduction. Scope of Studies Methodolog) Basic Data... ‘Surge Protection to be Provided for 230 and 13.8 kV System: Surge Arrester & Capacitor Ratings. Main Transformer Surge Protection EMTP Simulation & Result Generator Surge Protection Conelusion e ‘Appendix A —EMTP Plots Appendix B - Generator Surge Protection Calculation Appendix C - References » SNC-LAVALIN Surge and Lightning Protection WANETA EXPANSION PROJECT Page 4 of 36 Study of Date:17 February 2011 Document No. (020655-0000-47E3-001 Revision No.:_0 a | 1.2 INTRODUCTION SCOPE OF STUDIES This study is performed to examine the surge protection and insulation coordination for the WAX Generating Plant. The terms of reference is specified in Section 24.4 (a) (iv) of the Owner's Requirements as follows: * calculations of surge and lightning protection characteristics, and demonstration of equipment protection. The study examines the adequacy of protective margin of equipment BIL level specified in the OR in conjunction with the characteristic of the surge arrester to be chosen for the protection of the following equipment: a) 230 KV gas insulated switchgear (GIS) b) The 230/13.8 kV, 117/156/195 MVA generator step up transformers — ¢) The 186 MVA generators» d) The 15 kV switchgear including the generator breaker, isolated bus duct (IPB) and the station service switchgear The transmission line insulation coordination is not part of this study. -<}- METHODOLOGY Classical method is used in the study. However, due to the complexity in analyzing the incident and reflection surge voltage entering the GIS, an electromagnetic transient program (EMTP) is used to study the overvoltage on the 230 KV switchgear and transformer due to a lightning strike on the transmission line. The following standards are used in the study. Complete citations can be found in Appendix B: 1. IEEE 062.11 — IEEE standard for metal-oxide ssp to AC power circuits (>1 kV) / 2 IEEE C6222 - IEEE guide for the appifation,metaldxide surge artesters for altemating-current systems \ \ » Study of : ' SNC-LAVALIN Surge and Lightning Protection Cece an Document No. (020655-0000-47E3-001 Revision Nos 0 WANETA EXPANSION PROJECT Page 5 of 36 3. IEEE 57.12.00 — General requirements for liquid-immersed distribution, power, and regulating transformers BASIC DATA The following basic data specified in Section 24 and other relevant sections of the OR are used in the study and are summarized as follows: a) 230 KV System Voltage * Nominal voltage 230 kV * Maximum voltage 253 kV b) 230 KV GIS * Rated voltage 245 kV * BIL 1050 kV (section 44 — applicable to GIS and AIS equipment) ©) 230 kV Generator Transformer + HVnominal voltage 230 kV + HV winding BIL 900 kV + HV bushing BIL 950 kV * LV nominal voltage 13.8 KV + LV winding BIL 110 kV * LV bushing BIL 110 kV d) 13.8 kV Generator © Rated voltage 13.8 kV ) MV Apparatus (generator breaker, station service MV breaker! disconnect, IPB, VT/surge cubicle) * Rated voltage 13.8 kV * BIL 110 kV ‘* Switching surge 0.83 x 110 = 91.3 kVp [ref: 2 Table 5] (Assumed value as manufacturer data is usually not published for this voltage level) Details of the insulation level as specified/offered for the above equipment in the OR is depicted on Fig. 1 below:

You might also like