Professional Documents
Culture Documents
VoLTE Call Drop For Training 0307 PDF
VoLTE Call Drop For Training 0307 PDF
7.Mar, 2015
Joohyun,Kim
Summary-Case Study-1/2/3
Cluster_AP-TNDR-0236-C2(VoL)
• Key VoLTE Drop
— Call drop was caused by Mobile to Server test scenario(known issue)
‐ By server setting, every 15 minutes, UE could have call drop by no-RTP
‐ This is not KPI fail, but UE should have “Bye” message
‐ If there are call drop for VoLTE call attach in VoL “UE”, this is call drop(Refer to Next Slide)
— Call Drop was caused by end by user
‐ This is not KPI fail
— Call Drop was caused by 500 Server internal error
‐ Server Internal Error 5xx responses are failure responses given when a server itself has
erred
End By User
After sending the 100 Trying Message, UE receive the SIP 200 OK lately
• During the issue time, signal is good and RLC Layer is normal
• In abnormal case, time between 100 trying and QCI 1 Bearer with 183 session progress is
more than 20000ms
— In this event time is only depend on IMS core side
During the issue time, signal is good and RLC Layer is normal
During the issue time, There is only depend on IMS core side