Professional Documents
Culture Documents
A wide range of circuit components catering for the busy end-user installer are
available to - BS, IEC, UL and CSA standards. Bussmann offer a global package
to meet most circuit protection solutions. The range of circuit components
includes fuse holders, fuse banks, fuse bases/blocks and switch disconnectors
(skeleton).
CAMASTER: The innovative BS fuse holder incorporating a cam action built into
the fuse carrier for ease of removal from the base.
OPM 1038 Series: offers unbeatable protection against short circuit damage, in
eight combinations, for a broader coverage of todays process control panel
applications.
Modular Fuse Holders: A global solution in a 10 x 38mm package. The CH and
CH--E will accommodate fuse links manufactured to European and USA standards,
ensuring circuit protection up to 32 amps.
1
CAMASTER HRC Fuse Holders Bussmann ®
CAMASTER Fuse Holders, as standard, provide both bolted panel and DIN rail mounting features. When DIN rail
mounted all ratings of fuse holder give equal height and depth above and below the DIN rail.
Non removable full shrouding of live parts within the fuse base provided by the use on hinged shields which cannot
be omitted during installation and are designed so that insertion of the fuse carrier can only be made with them
correctly positioned.
Neon clip-in indicator accessories are available, the neon being lit when the fuse link has operated. (Minimum system
operation 90V).
The fuse carrier has a marking label for ease of circuit identification.
Ganging can be readily achieved by the use of standard accessories, providing improved safety related to isolation
and protection of 2 and 3 pole electrical circuits.
2
CAMASTER HRC Fuse Holders Bussmann ®
Standard front connected unit. Suitable for either Front/Back Stud and Double Back Stud
bolted panel or DIN rail mounting. connected units. These allow easy customer
conversion (illustrated below left) to either Front/
Back or Double Back configuration, by use of
Back Stud Assembly Packs, using only a screw-
driver.
Notes.
1 Type CM32FC is also available rated at 20A, catalogue number CM20F
2 For colours other than Black (standard) add the appropriate letter code:
W = White; G = Green and GY = Grey.
Conversion Sequence
3
SAFELOC HRC Fuse Holders Bussmann ®
4
SAFELOC HRC Fuse Holders Bussmann ®
For colours other than Black Max. Rec. Dimen s ion s (mm)
Ratin g
(standard), add the appropriate (A)
Cat. No. Cable Fu s e
mm 2
Lin k A B C D E F G H J K
letter code: W = White; G = Green;
GY = Grey, at the end of the Cata- 32 NNS 16 NSD 25.4 76.2 46.5 2.3 16.0 39.2 57.7 17.0 9.7 M6
logue Reference. 63 ENS 35 ESD 29.1 90.0 55.0 3.3 17.7 75.0 67.9 39.2 11.0 M8
Both CAMASTER and SAFELOC fuse holders can be used in Distribution Fuse Boards, CAMASTER is shown below on
the left and SAFELOC on the right. Details of both these products can be found in our Fusegear Catalogue avail-
able on request.
5
HRC Distribution Fuse Banks Bussmann ®
Characteristics
Gen eral O u tgoin g Circu it In comin g Circu it D iversity F actor
Rec. Max.
CAMAS T ER Rated Normal Normal
Rated Max. Cu rren t (A) Max.
F u se Ban k F u se Rec. Cu rren t
Rated Nomin al Cable Cable Termin al 4 6 8 12
P art Nu mbers Holder F u se Ratin g of
Voltage Cu rren t S ize size Bolt S ize W ay W ay W ay W ay
Ty pe Lin k 4 6 8 12 In comin g
(A) ( m m 2) ( m m 2)
W ay W ay W ay W ay F u se Lin k
(A)
32F B--CMC CM32FC 660 32 16 NITD 115 153 205 250 120 M10 250 0.9 0.8 0.8 0.66
32F B--CM CM32F 660 32 16 AAO 115 153 205 250 120 M10 250 0.9 0.8 0.8 0.66
63F B--CM CM63F 660 63 70 BAO 226 302 403 499 300 M12 500 0.9 0.8 0.8 0.66
100F B--CM CM100F 660 100 70 OSD 360 430 528 N/A 400 M12 560 0.9 0.8 0.66 N/A
S A F ELO C
Fuse Bank
P art Nu mbers
32F B--NNS NNS 550 32 16 NSD 115 153 205 250 120 M10 250 0.9 0.8 0.8 0.66
63F B--ENS ENS 550 63 35 ESD 226 302 403 499 300 M12 500 0.9 0.8 0.8 0.66
6
HRC Distribution Fuse Banks Bussmann ®
Dimensions (mm)
CAMAS T ER D imen sion s (mm)
No. of Ratin g
Catalogu e
W ay s (A) A B C D E F G H J K L M N
N u m b er
32F B4CMC 4 32 110.9 265 74.6
32F B6CMC 6 32 167.9 265 46.1
46.8 64.5 124.2 93.7 25.4 62.3 77 143.5 80 34
32F B8CMC 8 32 224.9 365 67.6
32F B12CMC 12 32 338.9 515 85.6
32F B4CM 4 32 131.7 265 70.5
32F B6CM 6 32 198.3 265 37.2
58.8 64.5 124.2 117.5 25.4 64.7 77 143.5 80 34
32F B8CM 8 32 264.9 365 53.9
32F B12CM 12 32 398.0 515 62.3
63F B4CM 4 63 149.6 265 55.2
63F B6CM 6 63 225.6 265 17.2
63 64.5 149.4 126 25.4 89.4 106 217 120 44
63F B8CM 8 63 301.6 365 29.7
63F B12CM 12 63 453.6 515 27.7
100F B4CM 4 100 149.6 265 55.2
100F B6CM 6 100 225.6 365 63 64.5 149.4 126 25.4 89.4 106 217 120 44 55.2
100F B8CM 8 100 301.6 515 103.7
S AF ELO C
Catalogu e
Nu mbers
32F B4NNS 4 32 110.9 265 74.6
32F B6NNS 6 32 167.9 265 46.1
38 50 109 76 25.4 62.3 77 143.5 80 34
32F B8NNS 8 32 224.9 365 67.6
32F B12NNS 12 32 338.9 515 85.6
63F B4ENS 4 63 120.6 265 69.5
63F B6ENS 6 63 181.6 265 39.2
45 58 148.2 90 25.4 89.4 106 21.7 120 44
63F B8ENS 8 63 242.6 365 58.7
63F B12ENS 12 63 364.6 515 72.7
7
Modular Fuse Holders CH Series Bussmann ®
For further detailed specifications on the CH range, please ask for Data Sheet number 1151
8
Modular Fuse Holders CH Series Bussmann ®
F u se h older
F u se h older size
catalogu e D escription F u se lin k ty pe
(mm)
n u m b er
CH101E 1 Pole C10G & C10M
CH101EN 1 Pole + Neutral C10G & C10M
10 x 38 CH C 10G C 10M
FNQ KTK AGU BAF
10 x 38 CHM
BAN FNM FWA FWC
10 x 38 CHCC LP-CC FNQ-R KTK-R
9
Modular Fuse Holders CH Series Bussmann ®
10
Safety J Fuse Holders Bussmann ®
The Safety J is a Class J Touch Safe Fuse Holder for use with
Bussmann Class J fuse links such as the LPJ and JKS. It is made from
thermoplastic with UL flammability 94VO and is available in 30 amp
and 60 amp versions at 600V, with or without indication.
Agency Approvals: UL listed UL 512 30-60A (guide IZLT, file 14853).
CSA Certified 30-60A (class 6225-01, file 47235).
• Compact design saves valuable panel space.
• Touch safe design from direct or indirect contact with live parts
(meets IP20).
• Dual port wire management system simplifies installation of
multiple loads connected to a single branch circuit (30A only).
• Integral 35mm DIN rail adapter built in, providing convenient
mounting.
• The gangable system means reduced inventory, limiting the need
to stock multiple poles.
• Removable fuse carrier provides added safety while replacing
the fuse link.
• Probe holes incorporated in the carrier provide easy access to
fuse for testing purposes.
• Internal DIN rail release latch makes it easily removable from the
DIN rail with just a screwdriver.
• Reinforced fuse clips are standard giving low resistance
performance.
• Built-in labelling system to enable circuit marking.
• Terminals ready to accept cables, saving valuable installation time.
• Open fuse indication available to enable fast response in
identifying open fuse links.
11
Class J Fuse Blocks Bussmann ®
Ordering Codes
Catalogue Number
Amps Poles Box Lug with Max. Cable Size
Screw* Pressure Plate* Box Lug
retaining clip
1 J60030-1S* J60030-1P* J60030-1C J60030-1CR
0.5 to 30 2 J60030-2S* J60030-2P* J60030-2C J60030-2CR 5.3mm2
3 J60030-3S* J60030-3P* J60030-3C J60030-3CR
1 - - J60060-1C J60060-1CR
31-60 2 - - J60060-2C J60060-2CR 33mm2
3 - - J60060-3C J60060-3CR
61-100 3 - - - J60100-3CR 53mm2
1 - - - J60200-1CR
101-200 127mm2
3 - - - J60200-3CR
1 - - - J60400-1CR
201-400 253mm2
3 - - - J60400-3CR
1 - - - J60600-1CR
401-600 (2)253mm2
3 - - - J60600-3CR
* Clip reinforcing springs are standard on fuse blocks rated 100A and above. Available on the 30A and 60A
blocks, to order add the letter R to the end of the part number.
Copper only connections available by changing CR suffix to COR
LPJ-SP is an example of one type of fuse link that can be accommodated in the J600 series
of Fuse Blocks.
12
Class J Fuse Blocks Bussmann ®
Catalogue Number
JP60030-3CR
JP60030-3PR (8.4 to 33.6mm JP60030-3COR
Panel (2.1 to 5.3mm aluminium wire) (2.1 to 33.6mm
wire) (2.1 to 33.6mm wire)
copper wire)
JP60030-3CRA
JP60030-3PRA (8.4 to 33.6mm JP60030-3CORA
With DIN rail
(2.1 to 5.3mm aluminium wire) (2.1 to 33.6mm
adaptor*
wire) (2.1 to 33.6mm wire)
copper wire)
* To order the DIN rail adaptor only use catalogue ref. JPA-3
13
Class H and R Fuse Blocks Bussmann ®
H250 series for use with Class H fuse links such as Bussmann NON
H600 series for use with Class H fuse links such as Bussmann NOS.
R250 series for use with Class R fuse links such as Bussmann LPN-RK,
FRN-R and KTS-R.
R600 series for use with Class R fuse links such as Bussmann LPS-RK,
FRS-R, DLS-R and KTS-R.
H250 and R250 rated at 250V ac - 0.1A to 600A
H600 and R600 rated at 600V ac - 0.1A to 600A
Agency Approvals:UL Listed (UL512. guide IZLT, file E14852).
CSA Certified (class 6225-01, file 47235).
Dimension details (mm) for 250V class H & R single pole fuse blocks.
0.1 to 30A - 250V 31 to 60A - 250V 61 to 100A - 250V
These dimensions refer to single pole fuse blocks only. Double and
triple pole configurations are available with slight variations in size
of individual fuse blocks. Please ask for Data sheet numbers 1110
for R250 series and 1112 for the H250 series for further details.
Various terminal types are available including Screw and Box Lug.
Please telephone our application help line for further details or refer
to the Data sheets listed above.
14
Class H and R Fuse Blocks Bussmann ®
Dimensional Details (mm) for 600V Class H & R Fuse Blocks single pole.
For further detailed information please ask for Data sheet number
1111 for R600 series and 1113 for H600 series
15
Modular Fuse Blocks Bussmann ®
Dimensions (mm)
1BS101 - 0 to 600V, 100Amps
1BS 101 fuse blocks The 1BS101 features a dovetail interlock and anti pivot pin. The
dovetail interlock permitting ganging of single pole units into multi-
pole configurations.
Mounting dimensions for various
fuse link types (mm).
Catalogue
A B C
References
FWA 70A-100A 49.3 16.0 95.4
FWH 35-60B 58.9 25.6 104.9
FWH 70-100B 72.4 39.1 118.3
FWX 35A-60A 59.4 26.1 105.4
FWX 70A-100A 59.7 26.4 105.6
KAC 1-30 63.5 30.2 109.4
KAC 35-60 88.9 55.6 134.8
KAC 70-100 105.7 72.3 151.6
KBC 35-60 88.9 55.6 134.8
KBC 70-100 93.0 59.6 138.9
LPJ 70SP-100SP 95.5 62.2 141.4
JJS 70-100 59.9 26.6 105.9
JKS 70-100 96.3 62.9 142.2
80-100L14C 89.9 56.6 135.8
80-100L09C 112.0 78.7 157.9
16
Modular Fuse Blocks Bussmann ®
17
HRC Fuse Bases for NH Style Fuse Links Bussmann ®
Dimensions of Single and Triple Pole size 00 and 0 NH Fuse Base (mm)
Catalogue reference SB (single pole) TB (triple pole).
Cat. Rated
Ref. & Current A B C D E F G H J
Size (A)
SB00 160 120 100 75 17 20 32 80 - -
SB0 160 170 150 75 17 20 32 104 - -
TB00 160 120 100 75 17 20 32 80 100 32
TB0 160 170 150 75 17 20 32 104 100 32
18
HRC Fuse Bases for NH Style Fuse Links Bussmann ®
Partition Barriers
Partition barriers are used when additional security demands have
to be met. To ensure additional safety, cover capes can be mounted
on the contact springs. These cover capes are available for single
pole and triple pole bases size 00 with bolt connections only. Cover
capes are to special order only.
To order Partition Barriers - reference PB followed by the size (00, 1,
2 or 3). Partition Barriers manufactured from a durable fabric.
C at . Rated
Ref. & Current A B C D E F G H J K L
Size (A)
SB1 250 200 175 89 27 25 60 152 - - 2 M10
SB2 400 230 200 98 27.5 35 60 152 - - 2.5 M12
SB3 630 240 210 110 28 45 80 152 - - 3 M12
TB1 250 200 175 89 27 25 60 152 184 60 2 M10
TB2 400 230 200 98 27.5 35 60 152 184 60 2.5 M12
TB3 630 240 210 110 28 45 80 152 244 80 3 M12
Size 0 fuse links fit into size 1 bases.
19
Vertical Fuse Bases for NH Style Fuse Links Bussmann ®
Rated
Catalogu e Rated
S ize Voltage (V) D escription
Referen ce Cu rren t (A)
ac
VF B100/00 00 160 660 100mm bus bar fixing
VF B185/00 00 160 660 185mm bus bar fixing
100mm bus bar fixing -
For a full list of accessories and detail of VF B100/00T S 00 160 660
touch safe
touch safe requirement for size 1, 2 and 3, VF B185/00T S 00 160 660
185mm bus bar fixing -
contact Bussmann Application engineers on touch safe
+44 (0)1509 882760 and 882766. VF B185/1 1 250 660 185mm bus bar fixing
185mm bus bar fixing -
Vertical fuse bases are available to special VF B185/1T S 1 250 660
touch safe
order only. VF B185/2 2 400 660 185mm bus bar fixing
185mm bus bar fixing -
VF B185/2T S 2 400 660
touch safe
VF B185/3 3 630 660 185mm bus bar fixing
185mm bus bar fixing -
VF B185/3T S 3 630 660
touch safe
Size A B C D E F G H J K L M
00 355 200 47 28 - - - 100 15 33 3 72
1, 2 & 3 634 370 - 54 84 97 650 185 24 41 3 124
20
Optima Overcurrent Protection Module Bussmann ®
• Removable module for convenient fuse link loading. LP-CC KTK C10M
• 35mm DIN rail or screw panel mounting.
KTK-R FNM C10G
• Dead-front construction
FNQ-R FNQ
• Can be padlocked for additional security.
• Option for remote open fuse status indication feature
available enabling less downtime.
• Offered with Class CC rejection clips or European
10 x 38mm clips to meet global needs.
21
Optima Overcurrent Protection Module Bussmann ®
Non-switched
Switched
22