BS TECH PTELTD Your Global Affianz Calibration —— a ceRTICATENO. 03651 PAGE: 1 OF 3 SALES ORDER NO. + BSB-17-0125489 cusromeR + PI-TRANGALINDO EKA PEREADA JL KERAPU BATU AMPAR, BATA ISLAND INDONESIA instRUMENT + METAL HARONESS TESTER MANUFACTURER + TIME: uooet vo. SHA SERALNO, crass TAG NO, = ance wun are causRareo atta? RECOMMENDED DUE DATE: 2llar18 2 @eaee (65210) %rh AMBIENT TEMPERATURE RELATIVE HUMIDITY {Tech's organisation and practices have been duly accreted and are compliant to the requirements of ISOMIEC 17025 the laboratory accreditation slandard. Our Quelty Management Sysiem ensures its compatibility withthe requirements of 180 9001:2008. ‘The reference measurement standerds used are traceable to Nallonal Meticlogy Centre (NUCSINGAPORE) andlor other National standards. MEASUREMENT TRACEABILITY REFERENCE STANDARDS AGO. SERIAL NO. AL DATE DUE DATE HARDNESS BLOCK HRC 701 BS 4411 : 2olun-2016 28-Jun-2017 HARNESS BLOCK HRB 84.6 Bs 1413 : 2tMay-2018——2A-May-2017 HARONESS BLOCK HV 60 Bs 1416 : 9.May-2016 9-May.2017 ‘CALIBRATED BY : ‘APPROVED BY : RISHNA NICHOLAS SHANE MISSON beststandards@ymail.com First City Komplek Block 2 #82-02, Batam Center, Batam, Indonesia Tel: 0778-463267, email CERTIFICATENO. ; BMB 3651 PAGE: 2 OF 3 METHOD OF CALIBRATION “The calibration certificate was produced in accordance to the instrument was calbted forthe pints specified inthe relevant in-House Tectnical Procedure, BSE 01,28 defined forthe instrument ‘The decid instrument has been calibrated at BS Laboratory under the ambient conditions sald inthe first page, [As Received Condon: Inia esting found the instrument tobe in specifiation forthe parameters tested ‘As Retumed Condltion [At the completion of the service, measured values were in specication forthe parameters tested RESULTS OF CALIBRATION +The expanded uncerainly of measurement associated withthe calibration is estimated al 2 confidence level of epprosimately 96% wih a coverage factor of k= 2 REMARKS {+The results of the calibration are given on the atached folowing pages. {+The results and thr associated uncertainties ae applicable atthe time of calibration |+Highighted values fll out ofthe manufacture’ specifications. Values not highlighted fall within the range alowed, + No agfustnent was done unless otherwise stated. {+The user should determine the suitability ofthe instrument fr its intended use. ‘The reports shall not be reproduced except in fl, unless the management representatve of 8S TECH PTE LTO has given ‘approval in wetng and comply wth the requitements speci in ISOMEC 17025. § 5 g g ie a Z First City Komplek Block 2 #82-02, Batam Center, Batam, Indonesia Tel: 0778-463267, email Calibration Certificate LAVA CERTIFICATE NUMBER: BME 3651 PAGE: 30F 3 TEST RESULT FOR HARONESS TESTER rds@ymail.com HRC 70.1 HRC 69.7 04 HRB 04.6 HRB 94.5, oa Hv 60.0 Hv 597 03 ‘TEST RESULT FOR BLOCK CALIBRATOR HLD 786 (¢ 6) HLD 791 5 First City Komplek Block 2 #B2-02, Batam Center, Batam, Indonesia Tel: 0778-463267, email: beststandar

You might also like