uc =) Marathon
Motors
Challenger
Totally Enclosed Fan Cooled Low
Voltage Cage Induction Motors
Includes IE2
AeglbandMARATHON Electric presents
‘CHALLENGER Series. Tere Squirrel
gage motors with excellent product
features ond outsonding
performance parameters. The design
oF his range & based an oan
technical laowhow and the level of
‘excellence associated with this
international company
manufacturing motors in India for
mmore thon half 0 cory
Stringent quality control procedures
are eloped of each soge of
production as a part of the company
policy to ensure that each motor is
manufactured to the requisite quality
Stondard ensuring customer
satisfaction.
Rating
‘AC. low volloge TEFC Sq, cage
Induction motor.
Frame size-71-355L
(designated as 12D71 - 12D355L
Challenger Series)
‘Output-
Pe 0.37 kW - 200 kW
4 Pole - 0.25 kW - 400 kw
6 Pole 0.55 KW 315 kW
8 Pole - 0.37 kW - 250 kW
Supply Voltage and Frequency
The Motors can be wound for any
voltage from 200 volt to 690 volt
fond for eter 50 He or 60 Hz
frequency. Standard motors are
wound for 3 phase, 415 volt, 50 Hz
supply condition.
All standard 50 Hz motors may be
Cperoted with 60 He supply of some
Saloge for sere output lowerer, i
the supply voltage at 0 Hz is 10:
20% IRgher than rated voltage ofthe
motor, eufpu can be increased by
10-18% depending on frome sia/
speed
The Motors can also be supplied for
dual voltage operation or for
operation wiih variable volloge ond
yoriable frequency supp iV, or
operation over a wide voltage
range. Separate VD" series of
motors suitable for VVVF drive are
Specially designed fo withstand
Figher diclece strength to combat
lage surges origin m high
Switching frequency with IGBT
The supply volloge is ossumed to be
sol sinusoidal and bolanced os
defined in 1S 325.
‘Standards
Challenger Series conforms to the following national and international standards.
‘Standard Indian’ International
Is EC NEMA*
Dimensions 151231 IEC 60072-1 | MGI Port 4
Is 2223
Performance 1S 325 IEC 6034-1 | MGI Part 12
Output 181231 = ‘MGI Part 10
Protection 15 4691 IEC 6034-5 | MGI - 1.268
‘Mounting Is 2253 IC 60034-7 | MGI Port 4
Motors Complying with IEC-60034-1 also comply with many national standards
cf European Countries. Motors suitable for NEMA stondards duly approved by
CSA/NRILC} and motor with CE marking are also manufactured. For full details
of motors as per NEMA standard CE marking, refer to MARATHON Electric.
[= Standard motor complies to
= Optional
Supply and Site Conditions
Standard motors are suitable for operation with variation in supply and site
conditions as indicated in Table 1 :-
In the event of sustained operation at extreme limits of supply variation the
temperature rise may exceed by 10XC
For other site conditions motor output should be adjusted as per
Tables 2 & 3.
When both ambient temperature and site cttude differ from standard, the
approximate permissible output is obtained by multiplying the foctors against
each variable as indicated in Tables 2 & 3.
TABLE - 1
‘Ambient | Altitude Voltage | Frequency | Combined
Temp. Variation | Variation | Variation
50yc* "1000 Mtrs.. + 10% + 5% + 10%
Table - 2
Deration For High Ambient Temp.
‘Ambient Temp. SOC [SHC] GNC | HC | TOC] BOC
Class ‘B’ Temp. Limit |100%/95%*| 90% | 85% 80% 70% | 60%
Class ‘F’ Temp. Limit | 100% | 100% | 95% 90% 80% | 70%
TABLE - 3
Deration For Attitude
Altitude 1500 m|2000 m}2500 m| 3000 m|3500 m)4000 m
Class ‘B’ Temp. Limit | 95% | 91% | 87% | 83% | 79% | 74%
Class ‘F Temp. 100% | 100% | 95% | 90% | 95% | 81%
For motor os per exceptions in Performance Char, he applicable ambient emperaie would be 451C wit drain as 95% fr SOYC ambien tempInsulation and Temperature Rise
Skondod motors wl eperote
sollsocorily in on embientferaperoture
range -201C to ae wn lass B
temperature rise and altitude up to
TOGO meters above sea level. :
The use of class B temperature rise
{(701C) ensures an exceptional margin
of safety and longo even in
‘bronmal operafing conditions
Standard motors wil wislond ambient
emperatures up to S51C OR 10%
overload OR orfverse supcly syslems.
‘Motors will Class ‘t sulation or
higher may be supplied as an optional.
Duties
‘Standard motos ‘are suitable for 4
‘operation with continuous running duty
{Bi ioe for moximure
3 col starts of 2 hot srs in
succession under rated load conditions
provided that a period
50 me eis beloreereter
serttg sxysnce's Glen
Motor 1 ait other duly conditions e.g
‘$2 ~ $9 may be offered on request
Performance
Challenger series offers outstanding
performance parameters. The
parameters ore better than those
Fecommended in |S 8789/ER2
{Improved elfciency) as per IS 12615
(2004) En (fie Re
complying to EMI (High eficien
ramets in occordance wih (8
12615 (2004) and CEMEP (European
‘Committee of Manufacturers of
Electrical Machines & Power
Electronics} / IE2 os per 1S:12615,
(2011) ore available on request under
'SE" series, Refer to table for 2, 4 & 6
poles on poges 11 & 12. For 4 pole
Frotor, Chelenger* designs ofer beter
efficiency than standard eff:2 motor.
Help bl on pe 12 While
‘ordering for Challenger, please
indicate accordingly
Constructional Features
Frame
Stator frames are made of elegant
looking, rugged cast iron enclosure.
Foo! mounted motors are provided
with integrally cast feet. Maximum
cooling surface is obtained by
ycdrengular dips of cooling
al
ele to Pefeence Ch for exepions
The rin bx tn on hemes oo flows
Terminal Remorks
‘Se 6)
20-2500] Side _| Reval ame hang
cfg eine box postin]
RAS or LS when viwed
from DE sd. Mok wih
Tep Thx homes re so
ibe ond can be offre
if specie
DaBaS/M | Side | Dot RAS, an be comet
(ro | edie iS frei, os
ther is nce option on
1S. Noto wi op 7. Box.
rans con be fred
pectin
Dai
ass.
Daa RS. canbe
proved oth Fone hat
thre pti! eine box
pra,
End bracket
Ribbed end brockels are provided
from frame sizes D160 upwards. For
frame sizes upto D225S single piece
cendbracket is used eliminating outer
beoring cop.
For frome sizes D200L and above,
Challenger Series ofers anather
unique feature of grease relief
crrangement as standard. Grease
nipple is provided os stondord ond
located on rim of endbracket
feciltting easy regreasing
Cooling Fan
Al fans are bidirectioncl. Optimum
cooling air flow for efficient heat
transfer is ensured by the design of
fan and cowl. Motors in this series
have been specially designed for