T@St REPOTE eres. sesusn ‘Sample Name a ‘Sample Number : #25, Heat No.:65353, Plate No.:HB17C-835, Product No.:640318002 Material & Specification: - Date of Receipt 2017.09.22 Date of Test 2017.10.12 - 2017.10.24 Test Method Used NACE TM0264-2011 Client Name : Jiangsu Sunpower Heat Exchanger & Pressure Vessel Co., Ltd. Client Address :No.108, Jing'er Road, Nanjing Chemical Industry Park, Nanjing, Jiangsu, 210048, P.R.China Test Results Cracking (%) CLR CTR csR * Control Sample CLR = 27.5% Crack Length Ratio, CLR=( Ea/W) x 100% Crack Thickness Ratio, CTR=( 5b/T) x 100% Crack Sensitivity Ratio, CSR= ¥(axb)/(WxT) x 100% 8 1. Men oe Ee ro Bt rg es ‘The results shown inthis test report refer ony tothe sample(s) tested unless otherwise stated. This test report can be checked ‘through the hitpi/e-checkina kr.s98.com. Tested by / Kyeseob Lee Approved by Technical Manager / Dongju Lee October 24, 2017 SGS Korea Co., Ltd. Material Laboratory el, (051) 690-7001 Fax. (051) 630-7006 Menter cf 86S Groth Gera do Suvetonce) ee ables i ees i eae & SG S Test Report Report No. : SGS-M17-13533 A. Test specimens - Dimensions of specimens (LX W X Th) : 251 - (99.91 X 19.99 X 12.67) mm 252 - (99.91 X 19.99 X 12.57) mm, 253 - (99.93 X 19.98 X 12.65) mm = Number of specimen : 3 = The ratio of the volume of test solution to the total surface area : 7.08 mL/cm’ - Used test solution : Solution A (5 % NaCl, 0.5 % CHsCOOH) B. Test equipments - HIC test chamber & test vessel No.3 (10 L) - pH meter (Mettler Toledo) = _ Dissolved oxygen meter (Mettler Toledo) = Stereo microscope (Carl Zeiss) + Microscope (Cari Zeiss) C. Test methods = Inacoordance with NACE TM0284-2011 = Degreasing validity verified by atomizer test ASTM F21 = Solution A with pH 2.7 + 0.1 ; at start of test after saturation (2.7 < pH < 3.3); at the end of test pH < 4.0 = Temperature of test solution : (25 + 3) © - HAS concentration at start and end of test > 2 300 1iL/L [ppm) = Duration of test : 96 hours Xito Lj Ce Ze 1D IS D. Test conditions ® ~ wor - Initial pH of test solution A : 2.70 ge S - Test duration in hours : 96 Start of test End of test Date and hour 10/12/2047 13: 40/16/2017 13:00 Phi cn een epee 288 [366 HS Concentration in L/L [ppm] 2.469 2435 | Temperature of test solution in © & SBR SS cee rere SESS So ce cvarecercoemen sem etme es rteeemnercoslaeoe an inane tet ee ‘Biiiateran ohn cecmecas nc an aepatbow este oso or aus isoubinibh suicuiiia (mbiscbmaganaein ime iacwee Ge masala” . Test Re po rt Report No. : SGS-M17-13533 E. Evaluation E1. Blistering Blisters whose dimensions are < 1.0 mm are not taken into account, [olojo afats] Number 0] | Diameter in mm. Kear Li 2TH Lower skin Besar eee este serene ees canes ree ‘nr fay Tm Gorey tot rumsatty owt Chris arr eer Pen a Voton a omang a rs ef teen Oey Seen tesa an nse eas Saye eas oropooneeipt) sot tewe.l| m searing isn 45602 Rape tne _ wa __Page 3/5 Montero $65 ropSost Gnd Suvetance)

You might also like