Professional Documents
Culture Documents
N2Xsefgby 3 X (25-300) MM 3.6/6 KV
N2Xsefgby 3 X (25-300) MM 3.6/6 KV
Construction Data
Application :
Nom. Overall Cable
For installation in the ground, indoors, cable
Cross Diameter Weight trunking and outdoors if increased mechanical
Section protection is required or where high-pulling
Area approx. approx. stresses may occur during installation or
mm² mm kg/km operation.
Standard Packing
25 - 50 sqmm supplied in wooden drum @ 1000 m
70 - 300 sqmm will be suplied in wooden drum on available length
Length Tolerance per drum ± 2%
Electrical Data
Conductor Inductance Current - Carrying
Short circuit
Capacity
current at 1 sec
Nom. DC AC at 30° C *
Cross Resistance Resistance
in air in ground Conductor Screen
Sect. at 20°C at 90°C
www.kmi.co.id
PT KMI Wire and Cable Tbk reserves the right to change the data content without prior notification
N2XSEFGbY
N2XSEFGbY 33x x(25-300)
(25-300) mm²
mm² 6/106/10
kV kV
Cu / XLPE / CTS / PVC / SFWA / PVC
(Copper Conductor, XLPE Insulated, Copper Tape Screen, Galvanized Steel Flat Wire Armor, PVC Sheathed)
Standard Specification : IEC 60502-2
Construction Data
Application :
Nom. Overall Cable
For installation in the ground, indoors, cable
Cross Diameter Weight trunking and outdoors if increased mechanical
Section protection is required or where high-pulling
Area approx. approx. stresses may occur during installation or
mm² mm kg/km operation.
Standard Packing
25 - 35 sqmm supplied in wooden drum @ 1000 m
50 - 300 sqmm will be suplied in wooden drum on available length
Length Tolerance per drum ± 2%
Electrical Data
Conductor Inductance Current - Carrying
Short circuit
Capacity
current at 1 sec
Nom. DC AC at 30° C *
Cross Resistance Resistance
in air in ground Conductor Screen
Sect. at 20°C at 90°C
www.kmi.co.id
PT KMI Wire and Cable Tbk reserves the right to change the data content without prior notification
N2XSEFGbY
N2XSEFGbY 33x x(25-300)
(25-300) mm²
mm² 8,7/15
8,7/15 kV kV
Cu / XLPE / CTS / PVC / SFWA / PVC
(Copper Conductor, XLPE Insulated, Copper Tape Screen, Galvanized Steel Flat Wire Armor, PVC Sheathed)
Standard Specification : IEC 60502-2
Construction Data
Application :
Nom. Overall Cable
For installation in the ground, indoors, cable
Cross Diameter Weight trunking and outdoors if increased mechanical
Section protection is required or where high-pulling
Area approx. approx. stresses may occur during installation or
mm² mm kg/km operation.
Standard Packing
25 sqmm supplied in wooden drum @ 1000 m
35 - 300 sqmm will be suplied in wooden drum on available length
Length Tolerance per drum ± 2%
Electrical Data
Conductor Inductance Current - Carrying
Short circuit
Capacity
current at 1 sec
Nom. DC AC at 30° C *
Cross Resistance Resistance
in air in ground Conductor Screen
Sect. at 20°C at 90°C
www.kmi.co.id
PT KMI Wire and Cable Tbk reserves the right to change the data content without prior notification
N2XSEFGbY
N2XSEFGbY 33x x(35-300)
(35-300) mm²
mm² 12/20
12/20 kV kV
Cu / XLPE / CTS / PVC / SFWA / PVC
(Copper Conductor, XLPE Insulated, Copper Tape Screen, Galvanized Steel Flat Wire Armor, PVC Sheathed)
Standard Specification : IEC 60502-2
Construction Data
Application :
Nom. Overall Cable
For installation in the ground, indoors, cable
Cross Diameter Weight trunking and outdoors if increased mechanical
Section protection is required or where high-pulling
Area approx. approx. stresses may occur during installation or
mm² mm kg/km operation.
Standard Packing
35 - 300 sqmm will be suplied in wooden drum on available length
Length Tolerance per drum ± 2%
Electrical Data
Conductor Inductance Current - Carrying
Short circuit
Capacity
current at 1 sec
Nom. DC AC at 30° C *
Cross Resistance Resistance
in air in ground Conductor Screen
Sect. at 20°C at 90°C
www.kmi.co.id
PT KMI Wire and Cable Tbk reserves the right to change the data content without prior notification
N2XSEFGbY
N2XSEFGbY 33x x(50-300)
(50-300) mm²
mm² 18/30
18/30 kV kV
Cu / XLPE / CTS / PVC / SFWA / PVC
(Copper Conductor, XLPE Insulated, Copper Tape Screen, Galvanized Steel Flat Wire Armor, PVC Sheathed)
Standard Specification : IEC 60502-2
Construction Data
Application :
Nom. Overall Cable
For installation in the ground, indoors, cable
Cross Diameter Weight trunking and outdoors if increased mechanical
Section protection is required or where high-pulling
Area approx. approx. stresses may occur during installation or
mm² mm kg/km operation.
Standard Packing
50 - 300 sqmm will be suplied in wooden drum on available length
Length Tolerance per drum ± 2%
Electrical Data
Conductor Inductance Current - Carrying
Short circuit
Capacity
current at 1 sec
Nom. DC AC at 30° C *
Cross Resistance Resistance
in air in ground Conductor Screen
Sect. at 20°C at 90°C
www.kmi.co.id
PT KMI Wire and Cable Tbk reserves the right to change the data content without prior notification