You are on page 1of 2

USP

MICROCODE VERSION 50-04-46-00/00


RELEASED 11/30/05
Newly supported features and functions for Version 50-04-46-00/00
NONE

The change of contents for Version 50-04-46-00/00

1 MSG cells become insufficient because MSG are released


wrongly
Phenomena FCv2 I/O in progress, the pair Suspends, host job abend and SVP cannot
be communicated. SSB=12c4 ( PDEV message FIFO is full) occurs.
Severity (High, Medium, Low) Low
Conditions of Occurrence This problem may occur when any of the conditions is met.
- Maintenance operation of DKA/HDD (DKA/HDD
REPLACE/Installation/Micro program exchange) is performed
- SIZ pair exists.
- FCv2 pair exists.
- QS pair exists.
Affected Products/Version DKCMAIN: 50-01-40-00/00 and higher
Fixed Product/Version DKCMAIN: 50-05-06-00/00
Category Flash Copy Version 2
Changed Part DKCMAIN

2 TC/TC Async/UR Pair Suspend


Phenomena When an external storage path failure occurred, the TC/TC Async/UR pairs
were suspended.
SSB: c761, cd29, cd33, 12c9 occurred.
Severity (High, Medium, Low) Medium
Conditions of Occurrence A. All versions of RAID500
B. An external subsystem is connected (either Universal Volume Manager
or Cross-System Copy is installed), and alternate paths are defined.
C. True Copy/True Copy for z/OS/True Copy Async/True Copy Async for
z/OS/Universal Replicator/Universal Replicator for z/OS are in use.
When all the conditions (A-C) are met, if any of the following failures
occurs, this phenomenon may occur.
a) A failure in a path between RAID500 and external storage
b) External device failure
c) RAID500 failure
d) Invalid response from the external device
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 50-05-06-00/00
Category True Copy/ True Copy for z/OS/ True Copy Async/ True Copy Async for
z/OS/ Universal Replicator/ Universal Replicator for z/OS/ Universal
Volume Manager/ Cross-System Copy
Changed Part DKCMAIN

HDS Confidential 1 of 2
3 Invalid DSB=0x80 reported
Phenomena When PPRC ESTPAIR is issued with MSGREQ from TSO, it may be
hanged up.
Severity (High, Medium, Low) High
Conditions of Occurrence This problem occurs when all the conditions are met.
- PPRC ESTPAIR is executed with MSGREQ from TSO (TC/TCA/SI)
- Use CU#1 or larger
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 50-05-06-00/00
Category Mainframe
Changed Part DKCMAIN

4 Command rejected after CHK2


Phenomena After detecting CHK2 due to a hardware failure in the host path, the
command was rejected.
Severity (High, Medium, Low) Medium
Conditions of Occurrence This problem occurs when all the conditions are met.
1. TCZ-Sync pair is in the Duplex state
2. Write operation in which the Sync performance enhancing logic runs
(Write operation within one track by UPWR command or FMTWR
command that does not include Record#1 or last record)
3. HALT I/O occurs during write data transfer (2) in the non Locate
domain or Locate Last domain.
Affected Products/Version DKCMAIN: 50-03-06-00/00 and higher
Fixed Product/Version DKCMAIN: 50-05-06-00/00
Category True Copy for z/OS
Changed Part DKCMAIN

5 Invalid read data in the case of FICON Read truncation


Phenomena In a mainframe host FICON connection, the read data became invalid, and
ICC or JOB ABEND occurred.
Severity (High, Medium, Low) High
Conditions of Occurrence This problem might occur when all the conditions are met.
(1). Mainframe FICON connection
(2). One command that reads multiple records
(MRDCKD/RDCKD/RDTRK/RDTRKD)
(3). Truncation in the command processing in (2) (CCWCNT < Actual
record length>)
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 50-04-46-00/00
Category FICON Connection
Changed Part DKCMAIN/HTP

HDS Confidential 2 of 2