You are on page 1of 1

13CR MARTENSITIC STAINLESS STEEL PQR AND WPS REVIEW

PROCEDURE QUALIFICATION RECORD (PQR)


Use current updated spec (DEP
1 SPECIFICATION 61.40.20.30-GEN FEBRUARY 2017). ISO
13847 no longer in use.
Pipe use for procedure Use 17.1mm as stated in the mill
2
qualification certificate and not 17.2mm
UNITS OF PARAMETERS NOT STATED
Test COUPON 004
3 (e.g size, temp, current, voltage,
DATE: 8/4/19
length, time, etc )
UNITS OF PARAMETERS NOT STATED
Test COUPON 005
4 (e.g size, temp, current, voltage,
DATE: 10/4/19
length, time, etc )
1. Not signed. Must be signed to make
it valid
POST WELD HEAT 2. Reference to the specification used
5
TREATMENT PROCEDURE for the WPS not stated
3. Entire document not consistent with
the work done
RADIOGRAPHIC TESTING Not signed. Should be signed to make
6
PROCEDURE it valid
WELDING PROCEDURE SPECIFICATION (WPS)
SPECIFICATION Reference the current spec (DEP
7 61.40.20.30-GEN FEBRUARY 2017). ISO
13847 no longer in use.
PQR NUMBER Input the PQR number. TO BE
8
QUALIFIED is only use for the pWPS.
Thickness and Thickness 1. Thickness of pipe use for
Range qualification should be 17.1mm as
stated in the pipe mill certification and
9 not 17.2mm

2. Thickness Range should be


17.1mm – 21.40mm
10 REPAIR WPS Not available. Should be included

You might also like