Xbee™ Series 2 Oem RF Modules: Product Manual - Zigbee Protocol
Xbee™ Series 2 Oem RF Modules: Product Manual - Zigbee Protocol
ZigBee® is a registered trademark of the ZigBee Alliance.
XBee™ Series 2 is a trademark of Digi International, Inc.
Technical Support: Phone: (801) 765‐9885
Live Chat: www.maxstream.net
E‐mail: rf‐xperts@maxstream.net
© 2007 Digi International, Inc. ii
XBee/XBee‐PRO OEM RF Modules ‐ ZigBee ‐ v1.x1x [2007.06.01]
Contents
1. XBee Series 2 OEM RF Modules 4 5. XBee Series 2 Command Reference Tables29
© 2007 Digi Internaitonal, Inc. iii
1. XBee Series 2 OEM RF Modules
The XBee Series 2 OEM RF Modules were engineered to
operate within the ZigBee protocol and support the unique
needs of low-cost, low-power wireless sensor networks.
The modules require minimal power and provide reliable
delivery of data between remote devices.
The modules operate within the ISM 2.4 GHz frequency
band.
© 2007 Digi International, Inc. 4
XBee Series 2 OEM RF Modules ‐ ZigBee ‐ v1.x1x [2007.06.01] Chapter 1 ‐ XBee Series 2 OEM RF Modules
1.2. Specifications
Table 1‐01. Specifications of the XBee Series 2 OEM RF Module (PRELIMINARY)
Performance
Power Requirements
General
Number of Channels
16 Direct Sequence Channels
(software selectable)
Addressing Options PAN ID and Addresses, Cluster IDs and Endpoints (optional)
Agency Approvals
Antenna Options: The ranges specified are typical when using the integrated Whip (1.5 dBi) and Dipole (2.1 dBi)
antennas. The Chip antenna option provides advantages in its form factor; however, it typically yields shorter range than
the Whip and Dipole antenna options when transmitting outdoors. For more information, refer to the “XBee Series 2
Antenna” application note located on MaxStream’s web site
http://www.maxstream.net/support/knowledgebase/article.php?kb=153
© 2007 Digi International, Inc. 5
XBee Series 2 OEM RF Modules ‐ ZigBee ‐ v1.x1x [2007.06.01] Chapter 1 ‐ XBee Series 2 OEM RF Modules
Figure 1‐01. Mechanical drawings of the XBee Series 2 OEM RF Modules (antenna options not shown)
.
XBee
The XBee Series 2 RF Module (through-hole) was designed to mount into a receptacle (socket) and
therefore does not require any soldering when mounting it to a board. The XBee Series 2
Development Kits contain RS-232 and USB interface boards which use two 20-pin receptacles to
receive modules.
Figure 1‐02. XBee Series 2 Module Mounting to an RS‐232 Interface Board.
MaxStream also recommends printing an outline of the module on the board to indicate the
orientation the module should be mounted.
© 2007 Digi International, Inc. 6
XBee Series 2 OEM RF Modules ‐ ZigBee ‐ v1.x1x [2007.06.01] Chapter 1 ‐ XBee Series 2 OEM RF Modules
Figure 1‐03. XBee Series 2 RF Module Pin Number
(top sides shown ‐ shields on bottom)
Table 1‐02. Pin Assignments for the XBee Series 2 Modules
(Low‐asserted signals are distinguished with a horizontal line above signal name.)
Pin # Name Direction Description
1 VCC - Power supply
2 DOUT Output UART Data Out
3 DIN / CONFIG Input UART Data In
4 DIO8 Either Digital I/O 8
5 RESET Input Module Reset (reset pulse must be at least 200 ns)
6 PWM0 / RSSI / DIO10 Output PWM Output 0 / RX Signal Strength Indicator / Digital IO
7 PWM / DIO11 Either Digital I/O 11
8 [reserved] - Do not connect
9 DTR / SLEEP_RQ/ DI8 Input Pin Sleep Control Line or Digital Input 8
10 GND - Ground
11 DIO4 Either Digital I/O 4
12 CTS / DIO7 Either Clear-to-Send Flow Control or Digital I/O 7
13 ON / SLEEP Output Module Status Indicator
14 [reserved] - Do not connect
15 Associate / DIO5 Either Associated Indicator, Digital I/O 5
16 RTS / DIO6 Either Request-to-Send Flow Control, Digital I/O 6
17 AD3 / DIO3 Either Analog Input 3 or Digital I/O 3
18 AD2 / DIO2 Either Analog Input 2 or Digital I/O 2
19 AD1 / DIO1 Either Analog Input 1 or Digital I/O 1
20 AD0 / DIO0 Either Analog Input 0 or Digital I/O 0
Design Notes:
• Minimum connections: VCC, GND, DOUT & DIN
• Minimum connections to support firmware upgrades: VCC, GND, DIN, DOUT, RTS & DTR
• Signal Direction is specified with respect to the module
• Module includes a 30k Ohm resistor attached to RESET
• Several of the input pull-ups can be configured using the PR command
• Unused pins should be left disconnected
© 2007 Digi International, Inc. 7
XBee Series 2 OEM RF Modules ‐ ZigBee ‐ v1.x1x [2007.06.01] Chapter 1 ‐ XBee Series 2 OEM RF Modules
© 2007 Digi International, Inc. 8
2. RF Module Operation
2.1. Serial Communications
The XBee Series 2 OEM RF Modules interface to a host device through a logic-level asynchronous
serial port. Through its serial port, the module can communicate with any logic and voltage
compatible UART; or through a level translator to any serial device (For example: Through a
MaxStream proprietary RS-232 or USB interface board).
Devices that have a UART interface can connect directly to the pins of the RF module as shown in
the figure below.
Figure 2‐01. System Data Flow Diagram in a UART‐interfaced environment
(Low‐asserted signals distinguished with horizontal line over signal name.)
Serial Data
Data enters the module UART through the DIN (pin 3) as an asynchronous serial signal. The signal
should idle high when no data is being transmitted.
Each data byte consists of a start bit (low), 8 data bits (least significant bit first) and a stop bit
(high). The following figure illustrates the serial bit pattern of data passing through the module.
Figure 2‐02. UART data packet 0x1F (decimal number ʺ31ʺ) as transmitted through the RF module
Example Data Format is 8‐N‐1 (bits ‐ parity ‐ # of stop bits)
The module UART performs tasks, such as timing and parity checking, that are needed for data
communications. Serial communications depend on the two UARTs to be configured with
compatible settings (baud rate, parity, start bits, stop bits, data bits).
The XBee Series 2 modules maintain small buffers to collect received serial and RF data. The serial
receive buffer collects incoming serial characters and holds them until they can be processed. The
serial transmit buffer collects data that is received via the RF link that will be transmitted out the
UART.
When serial data enters the RF module through the DIN Pin (3 pin), the data is stored in the serial
receive buffer until it can be processed.
© 2007 Digi International, Inc. 9
XBee/XBee‐PRO OEM RF Modules ‐ ZigBee ‐ v1.x1x [2007.06.01] Chapter 2 ‐ RF Module Operation
Hardware Flow Control (CTS). When the serial receive buffer is 17 bytes away from being full,
by default, the module de-asserts CTS (high) to signal to the host device to stop sending data
[refer to D7 (DIO7 Configuration) parameter]. CTS is re-asserted after the serial receive buffer
has 34 bytes of memory available.
Cases in which the serial receive buffer may become full and possibly overflow:
1. If the module is receiving a continuous stream of RF data, any serial data that arrives on
the DIN pin is placed in the serial receive buffer. The data in the serial receive buffer will be
transmitted over-the-air when the module is no longer receiving RF data in the network.
2. When data is ready to be transmitted, the module may need to discover a Network Address
and/or a Route in order to reach the destination node. Discovery overhead may delay
packet transmission.
Refer to the ZigBee Networks --> Mesh Routing sections for more information.
When RF data is received, the data is moved into the serial transmit buffer and is sent out the
serial port. If the serial transmit buffer becomes full enough such that all data in a received RF
packet won’t fit in the serial transmit buffer, the entire RF data packet is dropped.
Hardware Flow Control (RTS). If RTS is enabled for flow control (D6 (DIO6 Configuration)
Parameter = 1), data will not be sent out the serial transmit buffer as long as RTS (pin 16) is de-
asserted.
Cases in which the serial transmit buffer may become full resulting in dropped RF
packets
1. If the RF data rate is set higher than the interface data rate of the module, the module
could receive data faster than it can send the data to the host.
2. If the host does not allow the module to transmit data out from the serial transmit buffer
because of being held off by hardware flow control.
Figure 2‐03. Internal Data Flow Diagram
Serial
Receive
Buffer
Serial
Transmit
Buffer
© 2007 Digi International, Inc. 10
XBee/XBee‐PRO OEM RF Modules ‐ ZigBee ‐ v1.x1x [2007.06.01] Chapter 2 ‐ RF Module Operation
RF modules that contain the following firmware versions will support Transparent Mode:
1.0xx (coordinator) and 1.2xx (router/end device).
When operating in Transparent Mode, modules are configured using AT Commands and API
operation is not supported. The modules act as a serial line replacement - all UART data received
through the DIN pin is queued up for RF transmission. Data is sent to a module as defined by the
DH (Destination Address High) and DL (Destination Address Low) parameters.
When RF data is received by a module, the data is sent out the DOUT pin.
Serial-to-RF Packetization
Data is buffered in the serial receive buffer until one of the following causes the data to be
packetized and transmitted:
1. No serial characters are received for the amount of time determined by the RO (Packetiza-
tion Timeout) parameter. If RO = 0, packetization begins when a character is received.
2. Maximum number of characters that will fit (72) in an RF packet is received.
3. The Command Mode Sequence (GT + CC + GT) is received. Any character buffered in the
serial receive buffer before the sequence is transmitted.
Transmit Data Frames (received through the DIN pin (pin 3)) include:
• RF Transmit Data Frame
• Command Frame (equivalent to AT commands)
Receive Data Frames (sent out the DOUT pin (pin 2)) include:
• RF-received data frame
• Command response
• Event notifications such as reset, associate, disassociate, etc.
The API provides alternative means of configuring modules and routing data at the host
application layer. A host application can send data frames to the module that contain address and
payload information instead of using command mode to modify addresses. The module will send
data frames to the application containing status packets; as well as source, and payload
information from received data packets.
The API operation option facilitates many operations such as the examples cited below:
© 2007 Digi International, Inc. 11
XBee/XBee‐PRO OEM RF Modules ‐ ZigBee ‐ v1.x1x [2007.06.01] Chapter 2 ‐ RF Module Operation
When not receiving or transmitting data, the RF module is in Idle Mode. During Idle Mode, the RF
module is also checking for valid RF data. The module shifts into the other modes of operation
under the following conditions:
• Transmit Mode (Serial data in the serial receive buffer is ready to be packetized)
• Receive Mode (Valid RF data is received through the antenna)
• Sleep Mode (End Devices only)
• Command Mode (Command Mode Sequence is issued)
When serial data is received and is ready for packetization, the RF module will exit Idle Mode and
attempt to transmit the data. The destination address determines which node(s) will receive the
data.
Prior to transmitting the data, the module ensures that a 16-bit Network Address and route to the
destination node have been established.
If the 16-bit Network Address is not known, Network Address Discovery will take place. If a route
is not known, route discovery will take place for the purpose of establishing a route to the
destination node. If a module with a matching Network Address is not discovered, the packet is
discarded. The data will be transmitted once a route is established. If route discovery fails to
establish a route, the packet will be discarded.
Figure 2‐04. Transmit Mode Sequence
Successful
Transmission
Yes Yes
16-bit Network
Idle Mode Route Known? Transmit Data
New Address Known?
Transmission
No No
16-bit Network
Route Discovery
Address Discovery
Yes Yes
16-bit Network
Route Discovered?
Address Discovered?
No No
Data Discarded
© 2007 Digi International, Inc. 12
XBee/XBee‐PRO OEM RF Modules ‐ ZigBee ‐ v1.x1x [2007.06.01] Chapter 2 ‐ RF Module Operation
If a valid RF packet is received and its address matches the RF module’s MY (16-bit Source
Address) parameter, the data is transferred to the serial transmit buffer.
To modify or read RF Module parameters, the module must first enter into Command Mode - a
state in which incoming serial characters are interpreted as commands. Refer to the API Mode
section for an alternate means of configuring modules.
AT Command Mode
NOTE: Failure to enter AT Command Mode is most commonly due to baud rate mismatch. Ensure the
‘Baud’ setting on the “PC Settings” tab matches the interface data rate of the RF module. By default,
the BD parameter = 3 (9600 bps).
To Send AT Commands:
Send AT commands and parameters using the syntax shown below.
Figure 2‐05. Syntax for sending AT Commands
To read a parameter value stored in the RF module’s register, omit the parameter field.
The preceding example would change the RF module Destination Address (Low) to “0x1F”. To store
the new value to non-volatile (long term) memory, subsequently send the WR (Write) command.
For modified parameter values to persist in the module’s registry after a reset, changes must be
saved to non-volatile memory using the WR (Write) Command. Otherwise, parameters are
restored to previously saved values after the module is reset.
System Response. When a command is sent to the module, the module will parse and execute
the command. Upon successful execution of a command, the module returns an “OK” message. If
execution of a command results in an error, the module returns an “ERROR” message.
To Exit AT Command Mode:
1. Send the ATCN (Exit Command Mode) command (followed by a carriage return).
[OR]
2. If no valid AT Commands are received within the time specified by CT (Command Mode
Timeout) Command, the RF module automatically returns to Idle Mode.
© 2007 Digi International, Inc. 13
XBee/XBee‐PRO OEM RF Modules ‐ ZigBee ‐ v1.x1x [2007.06.01] Chapter 2 ‐ RF Module Operation
For an example of programming the RF module using AT Commands and descriptions of each
configurable parameter, refer to the "RF Module Configuration" chapter.
Sleep modes are supported on end devices only. Router and coordinator devices participate in
routing data packets and are intended to be mains powered. End devices must be joined to a
parent (router or coordinator) before they can participate on a ZigBee network. The parent device
does not track when an end device is awake or asleep. Instead, the end device must inform the
parent when it is able to receive data. The parent must be able to buffer incoming data packets
destined for the end device until the end device can awake and receive the data. When an end
device is able to receive data, it sends a poll command to the parent. When the parent router or
coordinator receives the poll command, it will transmit any buffered data packets for the end
device. Routers and coordinators are capable of buffering one broadcast transmission for sleeping
end device children.
The SM, ST, SP, and SN commands are used to configure sleep mode operation.
Data Management
The SP command on the parent determines how long the parent will buffer a packet. It should be
set to match the maximum SP value on any end device that may join to it. SP can be set up to 28
seconds (0xAF0).
Pin Sleep
Setting SM=1 or SM=2 configures a device as a pin-sleep enabled end device. When operating in
this mode, an end device monitors the Sleep_Request pin for a high state. When Sleep_Request
goes high, the module enters sleep mode once any pending transmissions have finished. The
module remains in a low power state until the Sleep_Request pin goes low.
When the module wakes from pin sleep, it sends a poll request to the parent to see if any data is
pending for the end device. Since routers and coordinators can only buffer data up to 30 seconds,
end devices should not remain in pin sleep longer than about 28 seconds if incoming data packets
must be received. Using pin sleep for more than 28 seconds is recommended only if incoming data
packets are not expected.
When the module wakes from a pin sleep mode, the CTS line goes low, and On/Sleep goes high.
Cyclic Sleep
Cyclic sleep allows the end device to sleep for a specified period of time. The period of time is
specified by SP. Since routers and coordinators can only buffer data packets for up to 30 seconds,
SP on end devices can be set up to 28 seconds (0xAF0). The module will wake after SP time and
send a poll request to the parent to check for data. If any serial or RF data is received, the ST time
is restarted. Once ST time has expired with no serial or RF activity, the end device will resume
cyclic sleep operation.
When the module wakes, CTS goes low allowing the application to send serial data to the module
if necessary. The On/Sleep indicator will be set high to alert the application that the end device has
awakened. If serial or RF data is received, the ST timer will be reset, otherwise, the end device will
resume low power operation.
Off board peripherals may wish to sleep longer than the maximum SP time of the end device. The
SN command can be used to not wake off board peripherals for longer than SP time.
For example, if SP=28 seconds, and SN=5, the end device will wake up every 28 seconds and poll
the parent for data. If no data is pending, the end device will return to sleep. In this example, if
the parent has no data for the end device, On/Sleep will go high after 140 seconds, assuming the
parent never has data for the end device. If the parent has data for the end device, On/Sleep will
go high and the SN counter will reset.
© 2007 Digi International, Inc. 14
3. ZigBee Networks
3.1. ZigBee Network Formation
A ZigBee Personal Area Network (PAN) consists of one coordinator and one or more routers and/or
end devices. A ZigBee Personal Area Network (PAN) is created when a coordinator selects a
channel and PAN ID to start on. Once the coordinator has started a PAN, it can allow router and
end device nodes to join the PAN.
When a router or end device joins a PAN, it receives a 16-bit network address and can transmit
data to or receive data from other devices in the PAN. Routers and the coordinator can allow other
devices to join the PAN, and can assist in sending data through the network to ensure data is
routed correctly to the intended recipient device. When a router or coordinator allows an end
device to join the PAN, the end device that joined becomes a child of the router or coordinator that
allowed the join.
End devices, however can transmit or receive data but cannot route data from one node to
another, nor can they allow devices to join the PAN. End devices must always communicate
directly to the parent they joined to. The parent router or coordinator can route data on behalf of
an end device child to ensure it reaches the correct destination. End devices are intended to be
battery powered and can support low power modes.
Figure 3‐01. Node Types / Sample of a Basic ZigBee Network Topology
The network address of the PAN coordinator is always 0. When a router joins a PAN, it can also
allow other routers and end devices to join to it. Joining establishes a parent/child relationship
between two nodes. The node that allowed the join is the parent, and the node that joined is the
child. The parent/child relationship is not necessary for routing data.
When a coordinator first comes up, it performs an energy scan on mulitple channels (frequencies)
to select an unused channel to start the PAN. After removing channels with high detected energy
levels, the coordinator issues an 802.15.4 beacon request command on the remaining, low energy
level channels. Any routers or coordinators respond to the beacon request frame with a small
beacon transmission that indicates the PAN identifier (PAN ID) that they are operating on, and
whether or not they are allowing joining.The coordinator will attempt to start on an unused PAN ID
and channel. After starting, the coordinator may allow other devices to join its PAN.
When a router first comes up, it must locate and join a ZigBee PAN. To do this, it issues an
802.15.4 beacon request command on multiple channels to locate nearby PANs. Nearby routers
and coordinators respond to the beacon request frame with a small beacon transmission,
indicating which channel and PAN ID they are operating on. The router listens on each channel for
these beacon frames, and determines which device it should join. If a valid PAN is found from one
of the received beacons, the router issues a join request to the device that sent the beacon. If
joining succeeds, the router will then receive a join confirmation from the device, indicating the
join was successful. Once the router joins the PAN, it can communicate with other devices on the
PAN and allow new devices to join to it.
© 2007 Digi International, Inc. 15
XBee/XBee‐PRO OEM RF Modules ‐ ZigBee ‐ v1.x1x [2007.06.01] Chapter 3 ‐ ZigBee Networks
When an end device first comes up, it must also locate and join a PAN. End devices follow the
same process as a router to join a PAN. Once the end device has successfully joined a PAN, it can
communicate with other devices on the PAN. However, since end devices cannot route data, it
must always communicate directly with its parent and allow the parent to route data in its behalf.
Figure 3‐02. Demonstration of Beacon Request and Beacon transmissions that take place during joining.
© 2007 Digi International, Inc. 16
XBee/XBee‐PRO OEM RF Modules ‐ ZigBee ‐ v1.x1x [2007.06.01] Chapter 3 ‐ ZigBee Networks
Zigbee supports device addressing and application layer addressing. Device addressing specifies
the destination address of the device a packet is destined to. Application layer addressing indicates
a particular application recipient, known as a Zigbee endpoint, along with message type fields
called cluster IDs.
The 802.15.4 protocol upon which the ZigBee protocol is built specifies two address types:
• 16-bit Network Addresses
• 64-bit Addresses
16-bit Network Addresses
A 16-bit Network Address is assigned to a node when the node joins a network. The Network
Address is unique to each node in the network. However, Network Addresses are not static - it can
change.
The following two conditions will cause a node to receive a new Network Address:
1. If an end device cannot communicate with its parent it may need to leave the network and
rejoin to find a new parent.
2. If the device type changes from router to end device, or vice-versa, the device will leave
the network and rejoin as the new device type.
ZigBee requires that data be sent to the 16-bit network address of the destination device. This
requires that the 16-bit address be discovered before transmitting data. See 3.2.3 Network
Address Discovery for more information.
64-bit Addresses
Each node contains a unique 64-bit address. The 64-bit address uniquely identifies a node and is
permanent.
The ZigBee application layers define endpoints and cluster identifiers (cluster IDs) that are used to
address individual services or applications on a device. An endpoint is a distinct task or application
that runs on a ZigBee device, similar to a TCP port. Each ZigBee device may support one or more
endpoints. Cluster IDs define a particular function or action on a device. Cluster IDs in the ZigBee
home controls lighting profile, for example, would include actions such as “TurnLightOn”,
“TurnLightOff”, “DimLight”, etc.
Suppose a single radio controls a light dimmer and one or more light switches. The dimmer and
switches could be assigned to different endpoint values. To send a message to the dimmer, a
remote radio would transmit a message to the dimmer endpoint on the radio. In this example, the
radio might support cluster IDs to “TurnLightOn”, “TurnLightOff”, or “DimLight”. Thus, for radio A to
turn off a light on radio B, radio A would send a transmission to the light switch endpoint on radio
B, using cluster ID “TurnLightOff”. This is shown in the figure below.
© 2007 Digi International, Inc. 17
XBee/XBee‐PRO OEM RF Modules ‐ ZigBee ‐ v1.x1x [2007.06.01] Chapter 3 ‐ ZigBee Networks
Figure 3‐03. ZigBee Data Transmission Higher Layer Addressing Fields
Src Address Dest Address Dest Endpoint Cluster ID Profile ID Src Endpoint
Figure 3‐04. ZigBee Layer‐Addressing Example
Endpoint 1 Endpoint 40
Endpoint 41
Endpoint 2
(radio B)
Endpoint 3
Endpoint 42
(radio A)
Cluster ID = TurnLightOff
All data packets are addressed using both device and application layer addressing fields. Data can
be sent as a broadcast, multicast, or unicast transmission.
Broadcast Transmissions
Broadcast transmissions within the ZigBee protocol are intended to be propagated throughout the
entire network such that all nodes receive the transmission. To accomplish this, all devices that
receive a broadcast transmission will retransmit the packet 3 times. Each node that transmits the
broadcast will also create an entry in a local broadcast transmission table. This entry is used to
keep track of each received broadcast packet to ensure the packets are not endlessly transmitted.
Each entry persists for 8 seconds. The broadcast transmission table holds 8 entries.
Since broadcast transmissions are retransmitted by each device in the network, broadcast
messages should be used sparingly.
Multicast Transmissions
Multicast transmissions operate similar to broadcast transmissions. Data packets are broadcast
throughout the network in a similar fashion. However, only devices that are part of the multicast
group will receive the data packets.
Unicast Transmissions
Unicast ZigBee transmissions are always addressed to the 16-bit address of the destination
device. However, only the 64-bit address of a device is permanent; the 16-bit address can change.
Therefore, ZigBee devices may employ network address discovery to identify the current 16-bit
© 2007 Digi International, Inc. 18
XBee/XBee‐PRO OEM RF Modules ‐ ZigBee ‐ v1.x1x [2007.06.01] Chapter 3 ‐ ZigBee Networks
address that corresponds to a known 64-bit address. Once the 16-bit address is known, a route to
the destination device must be discovered. ZigBee employs mesh routing using the Ad-hoc On-
demand Distance Vector routing (AODV) protocol to establish a route between the source device
and the destination.
Mesh Routing
Mesh routing allows data packets to traverse multiple nodes (hops) in a network to route data
from a source to a destination. The route a packet can take in a mesh network is independent of
the parent/child relationships established during joining. Before transmitting a data packet from
source to destination nodes, a route must be established. Route discovery is based on the AODV
(Ad-hoc On-demand Distance Vector routing) protocol.
© 2007 Digi International, Inc. 19
4. XBee Series 2 Network Formation
4.1. XBee Series 2 Network Formation
To create a ZigBee network, a coordinator must be started on a channel and PAN ID. Once the
coordinator has started, routers and end device can join the network. Routers and coordinator
devices can support up to 8 end device children each. Network formation is governed by the SC
(Scan Channels), ID (PAN ID), SD (Scan Duration), and NJ (Node Join Time) commands. The SC
and ID settings must be written using the WR command to affect network formation and joining.
In order to form a network, a coordinator must select an unused operating channel and PAN ID on
behalf of its network. To do this, the coordinator first performs an energy scan on all channels
specified by its SC (Scan Channels) parameter. The scan time on each channel is determined by
the SD (Scan Duration) parameter. Once the energy scan is completed, the coordinator sends a
beacon request on each of the SC channels and listens for any beacons. The information from the
energy scan and the beacon scan (active scan) is used to select an unused channel and PAN ID. If
the ID (PAN ID) parameter is set to 0xFFFF, the coordinator will select a random PAN ID.
Otherwise, the coordinator will start on the PAN ID specified by its ID parameter.
After the coordinator has started, it will allow nodes to join to it for a time based on its NJ (Node
Join Time) parameter. If the Associated LED function is enabled (D5 (DIO5 Configuration)
command), the Associate pin (pin 15) will toggle its output state 1x per second after the
coordinator stated. At this point, the operating channel and PAN ID can be read using the CH
(Operating Channel) and ID (PAN ID) commands. The 16-bit address of the coordinator is always
0. If API is enable (AP parameter > 0): The API modem status “coordinator Started” frame is sent
out the UART. The AI (Association Indication) command can be used at any point during the
coordinator startup routine to determine the status of the startup operation.
Before a router can participate in a ZigBee network, the router must locate a coordinator or
another router that has already joined a PAN, and attempt to join to it. To do this, it sends a
beacon request frame on each of the SC channels and listens for beacon frames. The scan duration
on each channel is determined by the SD parameter. The joining router will evaluate the received
beacons to find a coordinator or router that is allowing joins on a valid PAN ID, and attempt to join
to that device. If ID = 0xFFFF, the router will attempt to join to a device on any PAN ID. Otherwise,
the router will only attempt joining with a device that operates on the PAN ID specified by the ID
parameter. If a valid router/ coordinator is found, the router will attempt to join to that node. If
the join succeeds, the Router has successfully started.
After the Router has started, it will allow nodes to join to it for a time based on the NJ (Node Join
Time) parameter. If the Associated LED function is enabled(D5 (DIO5 Configuration) command)
the Associate pin (pin 15) will toggle its output state 2x per second after the router has joined. At
this point, the operating channel and PAN ID can be read using the CH (Operating Channel) and ID
(PAN ID) commands. The 16-bit Network Address of the router can be read using the MY (16-bit
Source Address) command. If API is enabled (AP parameter > 0): The API modem status “Joined”
is sent out the UART. The AI (Association Indication) command can be used at any point during the
router join routine to know the status of the startup operation.
Joining an end device to a PAN is similar to joining a router. Once the end device joins a PAN,
however, the end device cannot allow other devices to join to it. If the Associate LED function is
enabled (D5 (DIO5 Configuration) command), the Associate pin (pin 15) will toggle its output
state 2x per second after the end device has joined. At this point, the operating channel and PAN
ID can be read using the CH (Operating Channel) and ID (PAN ID) commands. The 16-bit network
© 2007 Digi International, Inc. 20
XBee/XBee‐PRO ZigBee OEM RF Modules v1.x1x [2007.06.01] Chapter 4 ‐ RF Module Configuration
address of the end device can be read using the MY (16-bit Source Address) command. If API is
enabled (AP parameter > 0), the API modem status “Joined” is sent out the UART. The AI
(Association Indication) command can be used at any point during the end device join routine to
know the status of the startup operation.
Once a coordinator has started, or a router or end device has joined the network, the device will
continue operating on that channel and PAN ID unless one of the following occurs:
1. The ID parameter changes, and is saved using the WR command
2. The SC parameter changes and is saved using the WR command, such that the current
operating channel is not included in the new SC parameter
3. The NR command is issued with either 0 or 1 as a parameter
If any of the above occurs on a coordinator, the coordinator will attempt to restart on a channel
and PAN ID based on the new saved ID and SC commands. On a router or end device, the above
conditions will cause the device to leave the network (if previously joined) and attempt to join a
new PAN using the saved ID and SC parameters.
© 2007 Digi International, Inc. 21
XBee/XBee‐PRO ZigBee OEM RF Modules v1.x1x [2007.06.01] Chapter 4 ‐ RF Module Configuration
XBee modules support both ZigBee device addressing and application-layer addressing.
All XBee/XBee-Pro modules can be identified by their unique 64-bit adresses or a user-
configurable ASCII string identifier The 64-bit address of a module can read using the SH and SL
commands. The ASCII string identifier is configured using the NI command. To transmit using
device addressing, only the destination address must be configured. The destination address can
be specified using either the destination device’s 64-bit address or its NI-string. The XBee modules
also support coordinator and broadcast addressing modes. Device addressing in the AT firmware is
configured using the DL, DH, or DN commands. In the API firmware, the ZigBee Transmit Request
API frame (0x10) can be used to specify destination addresses.
64-Bit Addressing
To address a node by its 64-bit address, the destination 64-bit address must be set to match the
64-bit address of the remote. In the AT firmware, the DH and DL commands set the destination
64-bit address. In the API firmware, the destination 64-bit address is set in the ZigBee Transmit
Request frame. The coordinator can be addressed by either setting the destination address to 0 or
by setting it to match the coordinator's 64-bit address. Broadcast transmissions can be sent by
setting the 64-bit address to 0x000000000000FFFF.
To send a packet to an RF module using its 64-bit Address (Transparent Mode)
Set the DH (Destination Address High) and DL (Destination Address Low) parameters of the
source node to match the 64-bit Address (SH (Serial Number High) and SL (Serial Number
Low) parameters) of the destination node.
Use the ZigBee Transmit Request API frame to set the DH (Destination Address High) and DL
(Destination Address Low) parameters of the source node to match the 64-bit Address (SH
(Serial Number High) and SL (Serial Number Low) parameters) of the destination node.
If the 16-bit address of the destination node is not known, set 16-bit Destination Network
Address to 0xFFFE (refer to the ‘API Addressing section below).
Since the ZigBee protocol relies on the 16-bit Network Address for routing, the 64-bit address
must be converted into a 16-bit Network Address prior to transmitting data. If a module does not
know the 16-bit Network Address for a given 64-bit address, it will transmit a broadcast Network
Address Discovery command. The module with a matching 64-bit address will transmit its 16-bit
network address back. Once the network address is discovered, the data will be transmitted.
The modules maintain a table that can store up to seven 64-bit addresses and their corresponding
16-bit Network Addresses.
API Addressing
API Mode provides the ability to store and maintain 16-bit Network Address tables on an external
processor. The 16-bit Network Address information is provided to the application through the
following:
• The ZigBee Transmit Status Frame
(contains the current 16-bit Network Address of the remote)
• The ND and DN commands
(return 64-bit and 16-bit Network Addresses of remote nodes)
With this information, a table can be built in an application that maps a 64-bit Address to the
corresponding 16-bit Network Address.
The ZigBee Transmit Request API frame specifies the 64-bit Address and the Network Address (if
known) that the packet should be sent to. By supplying both addresses, the module will forego
Network Address Discovery and immediately attempt to route the data packet to the remote. If
the Network Address of a particular remote changes, Network Address and route discovery will
© 2007 Digi International, Inc. 22
XBee/XBee‐PRO ZigBee OEM RF Modules v1.x1x [2007.06.01] Chapter 4 ‐ RF Module Configuration
take place to establish a new route to the correct node. Upon successful packet delivery, the TX
Status Frame will indicate the correct Network Address of the remote.
Table 4‐01. Sample table mapping 64‐bit Addresses to 16‐bit Network Addresses
Index 64-bit Address 16-bit Network Address
0 0013 4000 4000 0001 1234
1 0013 4000 4000 0002 5678
2 0013 4000 4000 01A0 A479
3 0013 4000 4000 0220 1F70
NI-String Addressing
Issue the DN (Destination Node) command using the NI (Node Identifier)-string of the destina-
tion node as the parameter.
Issue the DN command as stated above using the AT Command API frame.
When the DN command is issued, a broadcast transmission is sent across the network to discover
the module that has a matching NI (Node Identifier) parameter. If a module is discovered with a
matching NI-string, the DH and DL parameters will be configured to address the destination node
and the command will return both the 64-bit Address and the 16-bit Network Address of the
discovered node. Data can be transmitted after the DN (Destination Node) command finishes.
the AO command. See “API Frames” section for details.
Coordinator Addressing
A Coordinator can be addressed using its 64-bit address or NI string as described in the “NI-String
Addressing” section. Alternatively, since the ZigBee Coordinator has a Network Address of “0”, it
can be addressed by its 16-bit Network Address.
Broadcast Addressing
Broadcast transmissions are sent using a 64-bit address of 0x0000FFFF. Any RF module in the PAN
will accept a packet that contains a broadcast address. When configured to operate in Broadcast
Mode, receiving modules do not send ACKs (Acknowledgements).
NOTE: When programming the module, parameters are entered in hexadecimal notation (without
the “0x” prefix). Leading zeros may be omitted.
Refer to the “Broadcast Transmissions” for more information.
Application-layer addressing allows the application to specify endpoint and cluster ID values for
each transmission. Addressing multiple endpoints and cluster IDs can be accomplished by
explicitly setting these values as needed.
© 2007 Digi International, Inc. 23
XBee/XBee‐PRO ZigBee OEM RF Modules v1.x1x [2007.06.01] Chapter 4 ‐ RF Module Configuration
Coordinator Binding
The coordinator binding contains the 64-bit address of the coordinator. This table entry is
populated when the device joins the network.
Tx-Aggregation Binding
This binding table entry contains the 64-bit address of the aggregate (sink) node if one exists.
Data can be sent to the aggregate node by addressing this index in the binding table.
Tx-Explicit Binding
The Tx-Explicit binding table entry contains the destination address and endpoint information from
the last explicit transmission that was issued. This entry is modified whenever explicit addressing
is used in either the AT or API firmware as described in the "XBee Series 2 Addressing" section.
Command Binding
If a remote command request is received, the command binding entry stores information from the
device that initiated the command. For example, if the ND or DN command is issued, this binding
table entry would contain the source address of the device that sent the ND command.
The received data bindings contain addressing information for the last three received data
packets. The fourth entry is marked invalid. When a data packet is received, the address and
endpoint information is stored into the invalid entry. Then, the oldest entry is made invalid. Thus,
once an entry is created in the Received Data binding indexes, it will remain valid until three more
RF data packets are received.
© 2007 Digi International, Inc. 24
XBee/XBee‐PRO ZigBee OEM RF Modules v1.x1x [2007.06.01] Chapter 4 ‐ RF Module Configuration
Figure 4‐05. Demonstration of how entries in the received data bindings are replaced when an RF data
packet is received.
3rd
3rd INV INV
2nd newest entry becomes
oldest data entry
2nd
2nd 2nd 3rd
INV
DATA 1st Newest or 1st
3 Data entries +
1 invalid entry
DATA
User Bindings
These entries can be created and maintained by the application if needed. The following
commands can be used to modify the user bindings. See the command descriptions for formatting
details.
Table 4‐03.
Command Name Description
B+ Add Binding Creates a binding table entry at a specified User Binding index.
B- Remove Binding Removes a binding from a specified User Binding index.
BV View Binding Views one or more bindings in the binding table.
WB Write Binding Writes the binding table to non-volatile memory.
Multicast Addressing
Multicast addressing sends a broadcast message that will only be received by devices who
subscribe to a multicast group. The binding table is used to subscribe to a multicast group. To send
a multicast transmission, a binding table entry must exist where the type field is set to the
multicast type value. The 64-bit address in this entry becomes a multicast group address. Only
remote devices with a matching 64-bit multicast group will receive multicast transmissions. Once
the binding table is configured with a multicast binding entry, the binding table index can be
specified for a transmission using the BI command (AT firmware), or the Binding Table API
Command Frame (API firmware). See the XBee Binding Table section for details.
Endpoint Addressing
The ZigBee specification, Ember stack, and MaxStream application have reserved some endpoints
for different uses. Some of these endpoints are not accessible. Applications that will support
custom endpoints should select endpoints not already used by ZigBee, Ember, or MaxStream.
The cluster ID used by MaxStream on the serial data endpoint for serial data transmissions is
0x11.
The XBee Series 2 modules maintain a table of supported endpoints. If an endpoint will be used as
the source endpoint in a data transmission, the endpoint must first be defined in the endpoint
table.
© 2007 Digi International, Inc. 25
XBee/XBee‐PRO ZigBee OEM RF Modules v1.x1x [2007.06.01] Chapter 4 ‐ RF Module Configuration
The XBee Series 2 endpoint table operates similar to the binding table. Entries may be added,
removed, or viewed using the E+, E-, and EV commands respectively. Some table entries are
reserved for special purposes
Table 4‐04.
Endpoint Table Index Name Access
0 Command Endpoint Read-Only
1 Data Endpoint Read-Only
2 Tx-Explicit Endpoint Read-Write
3- 4 User Endpoints Read-Write
Command Endpoint
The command endpoint is used to send or reply to various commands. This endpoint must exist in
the application.
Data Endpoint
This endpoint is used to send serial data to other XBee Series 2 modules. It must always exist in
the application.
Tx-Explicit Endpoint
This entry is used as needed to define the source endpoint that must be defined for a data
transmission. If a transmit request is made, and the specified source endpoint does not exist, it
will be created temporarily at this endpoint table index.
User Endpoints
User endpoints are controlled entirely by the application. These endpoints may be added,
removed, or viewed in the API firmware using the following commandsSee the command
descriptions for command formatting details. At present, changes to the endpoint table are saved
to non-volatile memory when WR is issued..
Table 4‐05. ZigBee Data Transmissions Addressing Fields
Command Name Description
Creates an endpoint entry at a specified user endpoint
E+ Add Endpoint
index.
Removes an endpoint entry from a specified user endpoint
E- Remove Endpoint
index.
EV View Endpoint Views one or more endpoints in the endpoint table.
Network Mapping
Network mapping has provisions to identify all devices on a PAN.There are currently two ways to
do this either through the Node Discover (ND) Command or the API Child Joined Indicator. Both
are explained below.
Issuing the ND command on a device sends a broadcast node discovery command throughout the
PAN. All devices that receive the command will send a response that includes the device’s 64-bit
and 16-bit addresses, along with the NI-string and other information.
Routers and end devices can be configured to send a transmission after joining to alert the
coordinator, or the entire network, that the device has joined the network. When this message is
transmitted, the receiving device(s), if running API firmware, will send an advanced modem status
indicator out the UART to indicate the 64-bit and 16-bit addresses of the joining device.
© 2007 Digi International, Inc. 26
XBee/XBee‐PRO ZigBee OEM RF Modules v1.x1x [2007.06.01] Chapter 4 ‐ RF Module Configuration
The XBee Series 2 modules support both analog input and digital IO line modes on several
configurable pins.
The following table lists the pin functions supported on the modules
.
Table 4‐06.
Module Pin Names Module Pin Numbers Configuration Command
CD/DIO12 4 P2
PWM0/RSSI/DIO10 6 P0
PWM/DIO11 7 P1
DIO4 11 D4
CTS/DIO7 12 D7
ASSOC/DIO5 15 D5
RTS/DIO6 16 D6
AD3/DIO3 17 D3
AD2/DIO2 18 D2
AD1/DIO1 19 DI
AD0/DIO0 20 D0
Setting the configuration command that corresponds to a particular pin will configure the pin.
Parameters for the pin configuration commands typically include the following:
.
Table 4‐07.
© 2007 Digi International, Inc. 27
XBee/XBee‐PRO ZigBee OEM RF Modules v1.x1x [2007.06.01] Chapter 4 ‐ RF Module Configuration
See the command table for more information. Pullup resistors for each digital input can be enabled
using the PR command.
The IS command can be used to read the current value of all enabled A/D and digital input lines.
The format for the IS response is shown below. At the time, only one sample set is supported in
this frame.
A sample set consisting of 1 sample for each enabled ADC and/or DIO
channel. If any digital input lines are enabled, the first two bytes indicate the
state of all enabled digital input lines. Each bit in these two bytes corresponds
to one digital IO line, similar to the way each bit in the diglossia channel mask
corresponds. Note: only the digital input line that are enabled in the detail
channel mask have valid readings. Channels that are not enabled as digital
input lines will return a 0 in the sampled data set. If no pins are configured as
Var Sampled Data Set digital inputs, these 2 bytes will be omitted.
Following the digital input data, if any, each enabled analog channel will return
2 bytes (10bits). The analog data is scaled such that 0 represents 0V, and
0x3FF=1.2V. The analog input lines cannot measure more than 1.2V.
Information for each enabled analog channel is returned in order, starting with
AIN0 and finishing with AIN4. Only enabled analog input channels will return
data.
The AT firmware returns a carriage return delimited list containing the above-listed fields. The API
firmware returns an AT command response API frame with the IO data included in the command
data portion of the packet.
© 2007 Digi International, Inc. 28
5. XBee Series 2 Command Reference Tables
Special
Table 5‐08. Special Commands
AT
Name and Description Node Type1 Parameter Range Default
Command
Write. Write parameter values to non-volatile memory so that parameter modifications
persist through subsequent resets.
WR CRE -- --
Note: Once WR is issued, no additional characters should be sent to the module until
after the "OK\r" response is received.
WB Write Binding Table: Writes the current binding table to non-volative memory. CRE -- --
Restore Defaults. Restore module parameters to factory defaults. RE command does
RE CRE -- --
not reset the ID parameter.
Software Reset. Reset module. Responds immediately with an “OK” then performs a
FR reset ~2 seconds later. Use of the FR command will cause a network layer restart on the CRE -- --
node if SC or ID were modified since the last reset.
Network Reset. Reset network layer parameters on one or more modules within a PAN.
Responds immediately with an “OK” then causes a network restart. All network
configuration and routing information is consequently lost.
NR CRE 0-1 --
If NR = 0: Resets network layer parameters on the node issuing the command.
If NR = 1: Sends broadcast transmission to reset network layer parameters on all nodes
in the PAN.
Node types that support the command: C = Coordinator, R = Router, E = End Device
Addressing
Table 5‐09. Addressing Commands (Sub‐categories designated within {brackets})
AT Node
Name and Description Parameter Range Default
Command Type1
Destination Address High. Set/Get the upper 32 bits of the 64-bit destination address.
When combined with DL, it defines the destination address used for transmission.
DH2 0x000000000000FFFF is the broadcast address for the PAN. DH is not supported in
CRE 0 - 0xFFFFFFFF 0
API Mode. 0x0000000000000000 is the Coordinator’s 16-bit Network Address.
Destination Address Low. Set/Get the lower 32 bits of the 64-bit destination address.
2 When combined with DH, DL defines the destination address used for transmission. 0xFFFF(Coordinator)
DL CRE 0 - 0xFFFFFFFF
0x000000000000FFFF is the broadcast address for the PAN. DL is not supported in API 0 (Router/End Device)
Mode. 0x0000000000000000 is the Coordinator’s 16-bit Network Address.
ZigBee Application Layer Addressing. Set/read the Zigbee application layer
addressing enabled attribute. If enabled, data packets will use the SE, DE, and CI
ZA2 CRE 0-1 0
commands to address Zigbee application layer source and destination endpoints, and
the cluster ID fields in all data transmissions. ZA is only supported in the AT firmware.
Source Endpoint. Set/read the ZigBee application layer source endpoint value. If
ZigBee application layer addressing is enabled (ZA command), this value will be used
SE2 CRE 1 - 0xEF 0xE8
as the source endpoint for all data transmissions. SE is only supported in AT
firmware.The default value (0xE8) is the MaxStream data endpoint
Destination Endpoint. Set/read Zigbee application layer destination ID value. If
ZigBee application layer addressing is enabled (ZA command), this value will be used
DE 2 CRE 0 - 0xEF 0xE8
as the destination endpoint all data transmissions. DE is only supported in AT
firmware.The default value (0xE8) is the MaxStream data endpoint.
Cluster Identifier. Set/read Zigbee application layer cluster ID value. If ZigBee
application layer addressing is enabled (ZA command), this value will be used as the
CI2 CRE 0 - 0xFF 0x11
cluster ID for all data transmissions. CI is only supported in AT firmware.The default
value (0x11) is the MaStream transparent data cluster ID.
Binding Table Index. Set/read the binding table index value. If this value is set to a
BI2 valid binding table index, the addressing information at that index in the binding table CRE 0 - 0xFF 0xFF
will be used for all data transmissions. BI is only supported in AT firmware
0 - 0xFFFE
MY 16-bit Network Address. Get the 16-bit Network Address of the module. CRE 0xFFFE
[read-only]
0 - 0xFFFE
MP 16-bit Parent Network Address. Get the 16-bit parent Network Address of the module. E 0xFFFE
[read-only]
Serial Number High. Read high 32 bits of the RF module's unique IEEE 64-bit 0 - 0xFFFFFFFF
SH CRE factory-set
address. 64-bit source address is always enabled. [read-only]
Serial Number Low. Read low 32 bits of the RF module's unique IEEE 64-bit address. 0 - 0xFFFFFFFF
SL CRE factory-set
64-bit source address is always enabled. [read-only]
© 2007 Digi International, Inc. 29
XBee/XBee‐PRO ZigBee OEM RF Modules v1.x1x [2007.06.01] Chapter 5 ‐ XBee Series 2 Command Reference Tables
Table 5‐09. Addressing Commands (Sub‐categories designated within {brackets})
AT Node
Name and Description Parameter Range Default
Command Type1
Node Identifier. Stores a string identifier. The register only accepts printable ASCII
data. In AT Command Mode, a string can not start with a space. A carriage return ends
20-Byte printable
NI the command. Command will automatically end when maximum bytes for the string CRE --
ASCII string
have been entered. This string is returned as part of the ND (Node Discover) command.
This identifier is also used with the DN (Destination Node) command.
1. Node types that support the command: C=Coordinator, R=Router, E=End Device
2. Command supported by modules using AT Command firmware only
Networking & Security
Table 5‐010. Networking Commands (Sub‐categories designated within {brackets})
AT Node
Name and Description Parameter Range Default
Command Type1
Operating Channel. Read the channel number used for transmitting and receiving
CH CRE 0, 0x0B-0x1A (XBee) 0
between RF modules. Uses 802.15.4 channel numbers.
PAN ID. Set/Get the PAN (Personal Area Network) ID.
Coordinator - Set the preferred Pan ID. Set (ID = 0xFFFF) to auto-select.
Router / End Device - Set the desired Pan ID. When the device searches for a
Coordinator, it attempts to only join to a parent that has a matching Pan ID. Set (ID = 0x0234
ID CRE 0 - 0x3FFF, 0xFFFF
0xFFFF) to join a parent operating on any Pan ID. (291d)
Changes to ID should be written to non-volatile memory using the WR command. ID
changes are not used until the module is reset (FR, NR or power-up).
Broadcast Hops. Set/Read the maximum number of hops for each broadcast data
BH CRE 0 - 0x0F --
transmission. Setting this to 0 will use the maximum number of hops.
Node Discover Timeout. Set/Read the amount of time a node will spend discovering 0 - 0xFC
NT CRE 0x3C (60d)
other nodes when ND or DN is issued. [x 100 msec]
Node Discover. Discovers and reports all RF modules found. The following information
is reported for each module discovered.
MY<CR>
SH<CR>
SL<CR>
NI<CR> (Variable length)
PARENT_NETWORK ADDRESS (2 Bytes)<CR>
DEVICE_TYPE<CR> (1 Byte: 0=Coord, 1=Router, 2=End Device)
STATUS<CR> (1 Byte: Reserved) optional 20-Byte
ND PROFILE_ID<CR> (2 Bytes) CRE --
NI or MY value
MANUFACTURER_ID<CR> (2 Bytes)
<CR>
After (NT * 100) milliseconds, the command ends by returning a <CR>. ND also accepts
a Node Identifier (NI) as a parameter (optional). In this case, only a module that
matches the supplied identifier will respond.
If ND is sent through the API, each response is returned as a separate
AT_CMD_Response packet. The data consists of the above listed bytes without the
carriage return delimiters. The NI string will end in a "0x00" null character.
Destination Node. Resolves an NI (Node Identifier) string to a physical address (case-
sensitive). The following events occur after the destination node is discovered:
<AT Firmware>
1. DL & DH are set to the extended (64-bit) address of the module with the matching
NI (Node Identifier) string.
2. OK (or ERROR)\r is returned.
3. Command Mode is exited to allow immediate communication up to 20-Byte printable
DN CRE --
ASCII string
<API Firmware>
1. The 16-bit network and 64-bit extended addresses are returned in an API
Command Response frame.
If there is no response from a module within (NT * 100) milliseconds or a parameter is
not specified (left blank), the command is terminated and an “ERROR” message is
returned. In the case of an ERROR, Command Mode is not exited.
0 - Join notification
disabled
1 - Send notification only
to coordinator after joining
Join Notification. Set/read the join notification value. If enabled, the device will send a PAN
JN CRE 0
transmission after joining a PAN identifying itself to other devices in the PAN.
2 - Send notification as
broadcast transmission
after joining PAN
© 2007 Digi International, Inc. 30
XBee/XBee‐PRO ZigBee OEM RF Modules v1.x1x [2007.06.01] Chapter 5 ‐ XBee Series 2 Command Reference Tables
Table 5‐010. Networking Commands (Sub‐categories designated within {brackets})
AT Node
Name and Description Parameter Range Default
Command Type1
Scan Channels. Set/Read the list of channels to scan.
Coordinator - Bit field list of channels to choose from prior to starting network.
Router/End Device - Bit field list of channels that will be scanned to find a Coordinator/
Router to join.
SC Changes to SC should be written using WR command. SC changes are not used until CRE 1 - 0xFFFF[bitfield] 0x1FFE
the module is reset (FR, NR or power-up).
Bit (Channel): 0 (0x0B) 4 (0x0F) 8 (0x13) 12 (0x17)
1 (0x0C) 5 (0x10) 9 (0x14) 13 (0x18)
2 (0x0D) 6 (0x11) 10 (0x15) 14 (0x19)
3 (0x0E) 7 (0x12) 11 (0x16) 15 (0x1A)
Scan Duration. Set/Read the scan duration exponent. Changes to SD should be
written using WR command.
Coordinator - Duration of the Active and Energy Scans (on each channel) that are
used to determine an acceptable channel and Pan ID for the Coordinator to startup on.
Router / End Device - Duration of Active Scan (on each channel) used to locate an
available Coordinator / Router to join during Association.
Scan Time is measured as:(# Channels to Scan) * (2 ^ SD) * 15.36ms - The number of
SD CRE 0 - 7 [exponent] 3
channels to scan is determined by the SC parameter. The XBee can scan up to 16
channels (SC = 0xFFFF).
Sample Scan Duration times (13 channel scan):
If SD = 0, time = 0.200 sec
SD = 2, time = 0.799 sec
SD = 4, time = 3.190 sec
SD = 6, time = 12.780 sec
Node Join Time. Set/Read the time that a Coordinator/Router allows nodes to join.
This value can be changed at run time without requiring a Coordinator or Router to 0 – 0x40, 0xFF 0xFF
NJ CR
restart. The time starts once the Coordinator or Router has started. The timer is reset [x 1 sec] (always allows joining)
on power-cycle or when NJ changes.
Aggregate Routing Notification. Set/read time between consecutive aggregate route
AR broadcast messages. If used, AR should be set on only one device to enable many-to- CR 0 - 0xFF 0xFF
one routing to the device. Setting AR to 0 only sends one broadcast
Association Indication. Read information regarding last node join request:
0x00 - Successful completion - Coordinator started or Router/End Device found and
joined with a parent.
0x21 - Scan found no PANs 0 - 0xFF
AI 0x22 - Scan found no valid PANs based on current SC and ID settings CRE --
[read-only]
0x23 - Valid Coordinator or Routers found, but they are not allowing joining (NJ expired)
0x27 - Node Joining attempt failed
0x2A - Coordinator Start attempt failed‘
0xFF - Scanning for a Parent
RF Interfacing
Table 5‐011. RF Interfacing Commands
AT Node
Name and Description Parameter Range Default
Command Type1
0 - 4 (XBee )
0 = -10 / 10 dBm
Power Level. Select/Read the power level at which the RF module transmits conducted 1 = -6 / 12 dBm
PL CRE 4
power. 2 = -4 / 14 dBm
3 = -2 / 16 dBm
4 = 0 / 18 dBm
0-1,
Power Mode. Set/read the power mode of the device. Enabling boost mode will improve 0= -Boost mode disabled,
PM CRE 1= Boost mode enabled. 1
the receive sensitivity by 1dB and increase the transmit power by 2dB
1. Node types that support the command: C = Coordinator, R = Router, E = End Device
© 2007 Digi International, Inc. 31
XBee/XBee‐PRO ZigBee OEM RF Modules v1.x1x [2007.06.01] Chapter 5 ‐ XBee Series 2 Command Reference Tables
Table 5‐012. Serial Interfacing Commands
AT Node
Name and Description Parameter Range Default
Command Type1
0 - ZigBee Rx data
indicator enabled (0x90)
1 - Explicit Rx data
API Options. Configure options for API. Current options select the type of API RF data indicator API frame
AO2 receive frame that is used.
CRE
enabled (0x91)
0
2 - Binding Rx data
indicator API frame
enabled (0x92)
0-7
(standard baud rates)
0 = 1200 bps
Interface Data Rate. Set/Read the serial interface data rate for communication between 1 = 2400
the module serial port and host. 2 = 4800
3 = 9600
BD Any value above 0x07 will be interpreted as an actual baud rate. When a value above CRE 3
4 = 19200
0x07 is sent, the closest interface data rate represented by the number is stored in the 5 = 38400
BD register. 6 = 57600
7 = 115200
0x80 - 0x38400
(non-standard rates)
Packetization Timeout. Set/Read number of character times of inter-character silence
0 - 0xFF
RO required before packetization. Set (RO=0) to transmit characters as they arrive instead of CRE 3
[x character times]
buffering them into one RF packet.
0-1
0 = Disabled
1 = CTS Flow Control
3 = Digital input
4 = Digital output, low
D7 DIO7 Configuration. Select/Read options for the DIO7 line of the RF module. CRE 1
5 = Digital output, high
6 = RS-485 transmit
enable (low enable)
7 = RS-485 transmit
enable (high enable)
0 - Disabled
D6 DIO6 Configuration. Configure options for the DIO6 line of the RF module. CRE 0
1 - RTS Flow Control
0-1
0 = Disabled
DIO5 Configuration. Configure options for the DIO5 line of the RF module. 1 = Associated
D5 Options include: Associated LED indicator (LED blinks 1x/sec when the module is CRE indication LED 1
powered and 2x/sec when module is associated to a Coordinator.).
3 = Digital input
4
1. Node types that support the command: C = Coordinator, R = Router, E = End Device
2. Command supported by modules using API firmware only
I/O Commands
Table 5‐013. Serial Interfacing Commands
AT Node
Name and Description Parameter Range Default
Command Type1
0-1
P0 PWM0 Configuration. Select/Read function for PWM0. CRE 0 = Disabled 1
1 = RSSI PWM
0 - Unmonitored digital
input
3- Digital input,
monitored 0
P1 DIO11 Configuration. Configure options for the DIO11 line of the RF module. CRE
4- Digital output, default
low
5- Digital output, default
low
0 - Unmonitored digital
input
3- Digital input,
monitored
P2 DIO12 Configuration. Configure options for the DIO12 line of the RF module. CRE 4- Digital output, default 0
low
5- Digital output, default
low
© 2007 Digi International, Inc. 32
XBee/XBee‐PRO ZigBee OEM RF Modules v1.x1x [2007.06.01] Chapter 5 ‐ XBee Series 2 Command Reference Tables
Table 5‐013. Serial Interfacing Commands
AT Node
Name and Description Parameter Range Default
Command Type1
RSSI PWM Timer. Time RSSI signal will be output after last transmission. When RP =
RP CRE 0 - 0xFF [x 100 ms] 0x28 (40d)
0xFF, output will always be on.
IS Force Sample Forces a read of all enabled digital and analog input lines. CRE -- --
0, 2-5
0 – Disabled
2 - Analog input, single
D0 AD0/DIO0 Configuration. Select/Read function for AD0/DIO0. CRE ended 0
3 – Digital input
4 – Digital output, low
5 – Digital output, high
0, 2-5
0 – Disabled
2 - Analog input, single
AD1/DIO1 Configuration. Select/Read function for AD1/DIO1.
D1 CRE ended 0
3 – Digital input
4 – Digital output, low
5 – Digital output, high
0, 2-5
0 – Disabled
2 - Analog input, single
AD2/DIO2 Configuration. Select/Read function for AD2/DIO2. ended
D2 CRE 0
3 – Digital input
4 – Digital output, low
5 – Digital output, high
0, 2-5
0 – Disabled
2 - Analog input, single
AD3/DIO3 Configuration. Select/Read function for AD3/DIO3. ended
D3 CRE 0
3 – Digital input
4 – Digital output, low
5 – Digital output, high
0, 3-5
0 – Disabled
3 – Digital input
D4 DIO4 Configuration. Select/Read function for DIO4. CRE 0
4 – Digital output, low
5 – Digital output, high
Diagnostics
Table 5‐014. Diagnostics Commands
AT Node
Name and Description Parameter Range Default
Command Type1
VR Firmware Version. Read firmware version of the module. CRE 0 - 0xFFFF [read-only] Factory-set
HV Hardware Version. Read hardware version of the module. CRE 0 - 0xFFFF [read-only] Factory-set
1. Node types that support the command:C = Coordinator, R = Router, E = End Device
AT Command Options
Table 5‐015. AT Command Options Commands
AT Node
Name and Description Parameter Range Default
Command Type1
Command Mode Timeout. Set/Read the period of inactivity (no valid commands
CT2 received) after which the RF module automatically exits AT Command Mode and returns CRE 2 - 0x028F [x 100 ms] 0x64 (100d)
to Idle Mode.
CN2 Exit Command Mode. Explicitly exit the module from AT Command Mode. CRE -- --
Guard Times. Set required period of silence before and after the Command Sequence
1 - 0x0CE4 [x 1 ms] 0x3E8
GT2 Characters of the AT Command Mode Sequence (GT + CC + GT). The period of silence CRE
(max of 3.3 decimal sec) (1000d)
is used to prevent inadvertent entrance into AT Command Mode.
© 2007 Digi International, Inc. 33
XBee/XBee‐PRO ZigBee OEM RF Modules v1.x1x [2007.06.01] Chapter 5 ‐ XBee Series 2 Command Reference Tables
Table 5‐015. AT Command Options Commands
AT Node
Name and Description Parameter Range Default
Command Type1
Command Sequence Character. Set/Read the ASCII character value to be used
between Guard Times of the AT Command Mode Sequence (GT + CC + GT). The AT
Command Mode Sequence enters the RF module into AT Command Mode. 0x2B
CC2 CRE 0 - 0xFF
(‘+’ ASCII)
CC command is only applicable when using modules that contain the following “AT
Command” firmware versions: 8.0xx (Coordinator), 8.2xx (Router), 8.4xx (End Device)
1. Node types that support the command: C = Coordinator, R = Router, E = End Device
2. Command supported by modules using AT Command firmware only
Sleep Commands
Table 5‐016. Sleep Commands
AT Node
Name and Description Parameter Range Default
Command Type1
0-Sleep disabled
1-Pin sleep enabled
4-Cyclic sleep enabled
Note: When SM=0, the
device operates as a
SM Sleep Mode Sets the sleep mode on the RF module RE router. When SM 0
changes to a non-zero
value, the router leaves
the network and rejoins
as an end device. Only
end devices can sleep
Number of Sleep Periods. Sets the number of sleep periods to not assert the On/Sleep
SN pin on wakeup if no RF data is waiting for the end device. This command allows a host RE 1-0xFF 1
application to sleep for an extended time if no RF data is present
Sleep Period. This value determines how long the end device will sleep at a time, up to
28 seconds. (The sleep time can effectively be extended past 28 seconds using the SN 0x20 - 0xAF0 x 10ms
SP 0x7D0 (20
command.) On the parent, this value determines how long the parent will buffer a CRE (Quarter second
seconds)
message for the sleeping end device. It should be set at least equal to the longest SP resolution)
time of any child end device.
Time Before Sleep Sets the time before sleep timer on an end device.The timer is reset
ST 0x1388 (5
each time serial or RF data is received. Once the timer expires, an end device may enter RE 1 - 0xFFFE (x 1ms)
seconds)
low power operation. Applicable for cyclic sleep end devices only.
© 2007 Digi International, Inc. 34
6. API Operation
As an alternative to Transparent Operation, API (Application Programming Interface) Operations
are available. API operation requires that communication with the module be done through a
structured interface (data is communicated in frames in a defined order). The API specifies how
commands, command responses and module status messages are sent and received from the
module using a UART Data Frame.
Two API modes are supported and both can be enabled using the AP (API Enable) command. Use
the following AP parameter values to configure the module to operate in a particular mode:
• AP = 1: API Operation
• AP = 2: API Operation (with escaped characters)
When this API mode is enabled (AP = 1), the UART data frame structure is defined as follows:
Figure 6‐06. UART Data Frame Structure:
MSB = Most Significant Byte, LSB = Least Significant Byte
Any data received prior to the start delimiter is silently discarded. If the frame is not received
correctly or if the checksum fails, the module will reply with a module status frame indicating the
nature of the failure.
When this API mode is enabled (AP = 2), the UART data frame structure is defined as follows:
Figure 6‐07. UART Data Frame Structure ‐ with escape control characters:
Start Delimiter Length Frame Data Checksum
(Byte 1) (Bytes 2-3) (Bytes 4-n) (Byte n + 1)
MSB = Most Significant Byte, LSB = Least Significant Byte
Escape characters. When sending or receiving a UART data frame, specific data values must be
escaped (flagged) so they do not interfere with the data frame sequencing. To escape an
interfering data byte, insert 0x7D and follow it with the byte to be escaped XOR’d with 0x20.
© 2007 Digi International, Inc. 35
XBee/XBee‐PRO ZigBee OEM RF Modules v1.x1x [2007.06.01] Chapter 6 ‐ API Operation
Note: In the above example, the length of the raw data (excluding the checksum) is 0x0002 and
the checksum of the non-escaped data (excluding frame delimiter and length) is calculated as:
0xFF - (0x23 + 0x11) = (0xFF - 0x34) = 0xCB.
Checksum
Frame data of the UART data frame forms an API-specific structure as follows:
Figure 6‐08. UART Data Frame & API‐specific Structure:
cmdID cmdData
The cmdID frame (API-identifier) indicates which API messages will be contained in the cmdData
frame (Identifier-specific data). Refer to the sections that follow for more information regarding
the supported API types. Note that multi-byte values are sent big endian.
Modem Status
0x8A cmdData
Status (Byte 5)
0 = Hardware reset
1 = Watchdog timer reset
2 = Joined
3 = Unjoined
6 = Coordinator started
© 2007 Digi International, Inc. 36
XBee/XBee‐PRO ZigBee OEM RF Modules v1.x1x [2007.06.01] Chapter 6 ‐ API Operation
0x8C cm dD ata
© 2007 Digi International, Inc. 37
XBee/XBee‐PRO ZigBee OEM RF Modules v1.x1x [2007.06.01] Chapter 6 ‐ API Operation
AT Command
0x08 cmdData
Identifies the UART data frame for the host to Command Name - Two If present, indicates the requested parameter
correlate with a subsequent ACK (acknowledgement). ASCII characters that value to set the given register.
If set to ‘0’, no response is sent. identify the AT Command. If no characters present, register is queried.
Figure 6‐11. Example: API frames when reading the NJ parameter value of the module.
0x7E 0x00 0x04 0x08 0x52 (R) 0x4E (N) 0x4A (J) 0x0D
* Length [Bytes] = API Identifier + Frame ID + AT Command
** “R” value was arbitrarily selected.
Figure 6‐12. Example: API frames when modifying the NJ parameter value of the module.
0x7E 0x00 0x05 0x08 0x4D (M) 0x4E (N) 0x4A (J) 0x40 0xD2
Start Delimiter Length* API Identifier Frame ID** AT Command Parameter Value Checksum
* Length [Bytes] = API Identifier + Frame ID + AT Command + Parameter Value
** “M” value was arbitrarily selected.
A string parameter used with the NI (Node Identifier), ND (Node Discover) and DH (Destination
Address High) command is terminated with a 0x00 character.
0x09 cmdData
Identifies the UART data frame for the host to Command Name - Two If present, indicates the requested parameter
correlate with a subsequent ACK (acknowledgement). ASCII characters that value to set the given register.
If set to ‘0’, no response is requested. identify the AT Command. If no characters present, register is queried.
© 2007 Digi International, Inc. 38
XBee/XBee‐PRO ZigBee OEM RF Modules v1.x1x [2007.06.01] Chapter 6 ‐ API Operation
AT Command Response
0x88 cmdData
Frame ID (Byte 5 ) AT Command (Bytes 6-7) Status (Byte 8) Value (Byte(s) 9-n)
Identifies the UART data frame being reported. Command Name - Two
0 = OK The HEX (non-ASCII) value
Note: If Frame ID = 0 in AT Command Mode, ASCII characters that
1 = ERROR of the requested register
no AT Command Response will be given. identify the AT Command.
0x10 cmdData
16-bit Destination
Frame ID (Byte 5) Network Address (Bytes 14-15) Options (Byte 17) RF Data (Byte(s) 18-n)
Identifies the UART data fram e for the host to M SB first, LSB last. 0x01 = Disable ACK
Set to 0xFFFE for Up to 72 Bytes
correlate with a subsequent ACK (acknowledgem ent). 0x02 = Disable Network Address Discovery
Broadcast TX or if Network per packet
Setting Fram e ID to ‘0' will disable response frame. All other bits m ust be set to 0.
Address is not known
© 2007 Digi International, Inc. 39
XBee/XBee‐PRO ZigBee OEM RF Modules v1.x1x [2007.06.01] Chapter 6 ‐ API Operation
0x11 cmdData
Frame ID (byte 5)
Destination network address (if known). Set to Source endpoint (byte 16)
0xFFFE for broadcast transmissions or if the
destination network address is not known. Source endpoint for the transmission.
Up to 72 bytes
© 2007 Digi International, Inc. 40
XBee/XBee‐PRO ZigBee OEM RF Modules v1.x1x [2007.06.01] Chapter 6 ‐ API Operation
0x12 cmdData
© 2007 Digi International, Inc. 41
XBee/XBee‐PRO ZigBee OEM RF Modules v1.x1x [2007.06.01] Chapter 6 ‐ API Operation
0x8B cmdData
Frame ID (Byte 5) Remote Network Address (Bytes 6-7) Transmit Retry Count (Byte 8) Delivery Status (Byte 9) Discovery Status (Byte 10)
0x90 cm dData
© 2007 Digi International, Inc. 42
XBee/XBee‐PRO ZigBee OEM RF Modules v1.x1x [2007.06.01] Chapter 6 ‐ API Operation
0x91 cmdData
64-bit Source address (bytes 5-12) 16-bit Source network address (13-14)
Destination network address (if known). Set to 0xFFFE for
broadcast transmissions or if the destination network address
Destination 64-bit (extended) address. Set
is not known.
to 0xFFFF for broadcast.
© 2007 Digi International, Inc. 43
XBee/XBee‐PRO ZigBee OEM RF Modules v1.x1x [2007.06.01] Chapter 6 ‐ API Operation
0x92 cmdData
Options (byte 9)
Up to 72 bytes
© 2007 Digi International, Inc. 44
7. Examples
7.0.1. Starting an XBee Network
Transmit Data
1. Start a coordinator (refer to instructions above).
2. Add one or more Child router(s) to the coordinator (refer to instructions above).
3. Once the coordinator has started, all routers and End Devices should join to a parent and
their Associate LED should blink 2x per second.
4. If any nodes have not joined, read the AI command to determine why.
5. Issue the ATND command on the coordinator to get a list of all nodes on the network.
6. Use the ‘Terminal’ tab of the X-CTU Software to send serial data between nodes. The data
should be transmitted from the source to the destination node as specified by the DH & DL
parameters.
7. (Optional) Change the Destination address on any node to one of the 64-bit addresses dis-
covered using the ND command in step 5 (DH, DL Commands, or in the ‘ZigBee Transmit
Request’ API Frame). Then repeat step 6 to transmit data.
© 2007 Digi International, Inc. 45
XBee/XBee‐PRO ZigBee OEM RF Modules v1.x1x [2007.06.01] Chapter 7 ‐ Examples
Setup
The programming examples in this section require the installation of MaxStream's X-CTU Soft-
Refer to the ‘X‐CTU’ sec‐ ware and a serial connection to a PC. (MaxStream stocks RS-232 and USB boards to facilitate
tion of the Develop‐ interfacing with a PC.)
ment Guide [Appendix 1. Install MaxStream's X-CTU Software to a PC by double-clicking the "setup_X-CTU.exe" file.
B] for more information (The file is located on the MaxStream CD and under the 'Software' section of the following
regarding the X‐CTU web page: www.maxstream.net/support/downloads.php)
configuration software.
2. Mount the RF module to an interface board, then connect the module assembly to a PC.
3. Launch the X-CTU Software and select the 'PC Settings' tab. Verify the baud and parity set-
tings of the Com Port match those of the RF module.
NOTE: Failure to enter AT Command Mode is most commonly due to baud rate mismatch.
Ensure the ‘Baud’ setting on the ‘PC Settings’ tab matches the interface data rate of the RF mod-
ule. By default, the BD parameter = 3 (which corresponds to 9600 bps).
Example: Utilize the X-CTU “Terminal” tab to change the RF module's DL (Destination Address
Low) parameter and save the new address to non-volatile memory.
After establishing a serial connection between the RF module and a PC [refer to the 'Setup' sec-
tion above], select the “Terminal” tab of the X-CTU Software and enter the following command
lines (‘CR’ stands for carriage return):
© 2007 Digi International, Inc. 46
8. Manufacturing Support
8.1. Interoperability with other EM250 Devices
The XBee module may integrate functionality to some extent with other EM250 based devices. The
following should be considered when communicating between a MaxStream XBee module and
another EM250-based device.
The XBee firmware inserts 8 bytes at the beginning of the data payload that represent the 64-bit
address of the source module. Custom devices that transmit to an XBee or receive data from an
XBee should make provisions to manage these 8 address bytes in the payload. Data packets
destined for an XBee module should include the source address of the sending device with the
most significant byte copied first.
Once module parameters are determined, MaxStream can manufacture modules with specific
customer-defined configurations. These custom configurations can lock in a firmware version or
set command values when the modules are manufactured, eliminating the need for customers to
adjust module parameters on arrival. Contact MaxStream to create a custom configuration.
XBee Series 2 modules use a modified version of Ember’s boot loader. This version supports a
custom entry mechanism. To invoke the boot loader, do the following:
1. Set DTR low (TTL 0V) and RTS high.
2. Send a serial break to the DIN pin and power cycle or reset the module.
3. When the module powers up, DTR and DIN should be low (TTL 0V) and RTS should be high.
4. Terminate the serial break and send a carriage return at 115200bps to the module.
5. If successful, the module will send the Ember boot loader menu out the DOUT pin at
115200bps.
6. Commands can be sent to the boot loader at 115200bps.
Firmware on the XBee Series 2 modules can be upgraded using the MaxStream x-CTU program to
interface with the DIN and DOUT serial lines, or with an InSight programmer device via InSight
header.
© 2007 Digi International, Inc. 47
Appendix A:Definitions
Definitions
Table A‐01. Terms and Definitions
Coordinator A node that has the unique function of forming a network. The
coordinator is responsible for establishing the operating channel and
PAN ID for an entire network. Once established, the coordinator can
form a network by allowing routers and end devices to join to it.
Once the network is formed, the coordinator functions like a router
(it can participate in routing packets and be a source or destination
for data packets).
-- One coordinator per PAN
-- Establishes/Organizes PAN
-- Can route data packets to/from other nodes
-- Can be a data packet source and destination
-- Mains-powered
Refer to the XBee Series 2 coordinator section for more information.
End device End devices must always interact with their parent to receive or
transmit data. (See ‘joining definition.) They are intended to sleep
periodically and therefore have no routing capacity.
An end device can be a source or destination for data packets but
cannot route packets. End devices can be battery-powered and offer
low-power operation.
-- Several end devices can operate in one PAN
-- Can be a data packet source and destination
-- All messages are relayed through a coordinator or router
-- Lower power modes
ZigBee Protocol
© 2007 Digi International, Inc. 48
XBee Series 2 OEM RF Modules ‐ ZigBee ‐ v1.x1x [2007.06.01] Chapter A ‐ Definitions
Table A‐01. Terms and Definitions
Network Address The 16-bit address assigned to a node after it has joined to another
node. The coordinator always has a network address of 0.
Operating Channel The frequency selected for data communications between nodes. The
operating channel is selected by the coordinator on power-up.
Energy Scan A scan of RF channels that detects the amount of energy present on
the selected channels. The coordinator uses the energy scan to
determine the operating channel.
Route Reply Unicast transmission sent back to the originator of the route request.
It is initiated by a node when it receives a route request packet and
its address matches the Destination Address in the route request
packet.
Route Discovery The process of establishing a route to a destination node when one
does not exist in the Routing Table. It is based on the AODV (Ad-hoc
On-demand Distance Vector routing) protocol.
© 2007 Digi International, Inc. 49
Appendix B:Migrating from the 802.15.4
Protocol
This following are some of the differences in the ZigBee firmware assuming familiarity with the
802.15.4 application:
• ZigBee Command Set
• Address Assignment
• API / AT Firmware Versions
Also, refer to the “Getting Started” section for more information.
Modified Commands
• CH - Read Only command that displays the operating channel that was selected from SC.
• MY - Read Only command that displays the assigned 16-bit Network Address of the device.
• AI - ZigBee definitions added to this command. See documentation.
• A1, A2 and CE commands are not supported.
New Commands
• NJ (Node Join Time) - This value determines how long a Coordinator or Router will allow other
devices to join to it. This command is supported on Coordinators & Routers only.
• MP (16-bit Parent Network Address). This value represents the 16-bit parent Network Address
of the module.
• BH (Broadcast Hops). This value sets the maximum number of hops for each broadcast data
transmission. Setting this to 0 will use the maximum number of hops.
API / AT Firmware Versions
The 802.15.4 firmware supports the AP command for setting the module into No API (AP=0), API
without escaping (AP=1), or API with escaping (AP=2) modes. The first digit in the 802.15.4
firmware versions is a '1'.
The ZigBee firmware comes in different versions to support the API interface (AP 1, 2 modes) or
the AT command set (AP 0 mode). The first digit in the ZigBee firmware versions is an '8'.
The following is a list of firmware versions:
• 1.0xx - Coordinator, AT Command support (Transparent Mode)
• 1.1xx - Coordinator, API support (AP 1, 2)
• 1.2xx - Router, End Device, AT Command support (Transparent Mode)
• 1.3xx - Router, End Device, API support (AP 1, 2)
© 2007 MaxStream, Inc. 50
Appendix C: Agency Certifications
FCC, IC, and ETSI approvals pending.
© 2007 MaxStream, Inc. 51
Appendix D:Development Guide
XBee Series 2 Development Kits
The XBee Series 2 Professional Development Kit includes the hardware and software needed to
rapidly create long range wireless data links between nodes (XBee Series 2 Starter Kits that
contain fewer modules and accessories are also available).
Table D‐01. Items Included in the Development Kit
Item Qty. Description Part #
(1) OEM RF Module, AT Coordinator with wire antenna XB24-BWIt-002
(1) OEM RF Module, AT Router/End Device with wire antenna XB24-BWIT-004
XBee Series 2 Module 5 (1) OEM RF Module, AT Router/End Device with U.FL antenna XB24-BUIT-004
(1) OEM RF Module, AT Router/End Device with chip antenna XB24-BCIT-004
(1) OEM RF Module, AT Router/End Device with SMA antenna XB24-BSIT-004
Board for interfacing between modules and RS-232 nodes
RS-232 Development Board 4 XBIB-R
(Converts signal levels, displays diagnostic info, & more)
Board for interfacing between modules & USB nodes
USB Development Board 1 XBIB-U
(Converts signal levels, displays diagnostic info, & more)
RS-232 Cable Cable for connecting RS-232 interface board with DTE nodes
1 JD2D3-CDS-6F
(6’, straight-through) (nodes that have a male serial DB-9 port - such as most PCs)
USB Cable (6’) 1 Cable for connecting USB interface board to USB nodes JU1U2-CSB-6F
Serial Loopback [Red] Adapter for configuring the module assembly (module + RS-232
1 JD2D3-CDL-A
Adapter interface board) to function as a repeater for range testing
NULL Modem Adapter [Black] Adapter for connecting the module assembly (module + RS-232
1 JD2D2-CDN-A
(male-to-male) interface board) to other DCE (female DB-9) nodes
NULL Modem Adapter [Gray] Adapter for connecting serial nodes. It allows users to bypass
1 JD3D3-CDN-A
(female-to-female) the radios to verify serial cabling is functioning properly.
Power Adapter (9VDC, 1 A) 1 Adapter for powering the RS-232 development board JP5P2-9V11-6F
Battery Clip (9V) 1 Clip for remotely powering the RS-232 board w/ a 9V battery JP2P3-C2C-4I
RPSMA Antenna 2 RPSMA half-wave dipole antenna (2.4 GHz, 2.1 dB) A24-HASM-450
RF Cable Assembly 2 Adapter for connecting RPSMA antenna to U.FL connector JF1R6-CR3-4I
CD 1 Documentation and Software MD0030
Step-by-step instruction on how to create wireless links
Quick Start Guide 1 MD0026
& test range capabilities of the modules
Interfacing Options
The development kit includes RS-232 and USB interface boards. The boards provide a connection
to PC ports and therefore give access to the RF module registries. Parameters stored in the
registry allow OEMs and integrators to customize the modules to suite the needs of their data
radio systems.
The following sections illustrate how to use the interface boards for development purposes. The
MaxStream Interface board provides means for connecting the module to any node that has an
available RS-232 or USB connector. Since the module requires signals to enter at TTL voltages,
one of the main functions of the interface board is to convert signals between TTL levels and RS-
232 and USB levels.
© 2007 Digi International, Inc. 52
XBee/XBee‐PRO ZigBee OEM RF Modules v1.x1x [2007.06.01] Development Guide
Note: In the following sections, an OEM RF Module mounted to an interface board will be referred to as
a "Module Assembly".
External Interface
Figure B‐01. Front View The Reset Switch is used to reset (re-boot) the RF module. This
switch only applies when using the configuration tabs of MaxStream’s
X-CTU Software.
Figure B‐02. Back View DIP Switch functions are not supported in this release. Future down-
loadable firmware versions will support DIP Switch configurations.
B‐02a.
DIP Switch
© 2007 Digi International, Inc. 53
XBee/XBee‐PRO ZigBee OEM RF Modules v1.x1x [2007.06.01] Development Guide
Figure B‐03. Pins used on the female RS‐232 (DB‐9) Serial Connector
Table D‐02. Pin Assignments and Implementations
* Functions listed in the implementation column may not be available at the time of release.
© 2007 Digi International, Inc. 54
XBee/XBee‐PRO ZigBee OEM RF Modules v1.x1x [2007.06.01] Development Guide
Wiring Diagrams
Figure B‐04. DTE node (RS‐232, male DB‐9 connector) wired to a DCE Module Assembly (female DB‐9)
Figure B‐05. DCE Module Assembly (female DB‐9 connector) wired to a DCE node (RS‐232, male DB‐9)
Sample Wireless Connection: DTE <--> DCE <--> DCE <--> DCE
Figure B‐06. Typical wireless link between DTE and DCE nodes
© 2007 Digi International, Inc. 55
XBee/XBee‐PRO ZigBee OEM RF Modules v1.x1x [2007.06.01] Development Guide
Adapters
The development kit includes several adapters that support the following functions:
• Performing Range Tests
• Testing Cables
• Connecting to other RS-232 DCE and DTE nodes
• Connecting to terminal blocks or RJ-45 (for RS-485/422 nodes)
NULL Modem Adapter (male-to-male)
Part Number: JD2D2-CDN-A (Black, DB-9 M-M) The male-to-male NULL modem adapter is
used to connect two DCE nodes. A DCE node connects with a straight-through cable to the male
serial port of a computer (DTE).
Figure B‐07. Male NULL modem adapter and pinouts
Figure B‐08. Example of a MaxStream Radio Modem (DCE node) connecting to another DCE node)
Part Number: JD3D3-CDN-A (Gray, DB-9 F-F) The female-to-female NULL modem adapter is
used to verify serial cabling is functioning properly. To test cables, insert the female-to-female
NULL modem adapter in place of a pair of module assemblies (RS-232 interface board + XTend
Module) and test the connection without the modules in the connection.
Figure B‐09. Female NULL modem adapter and pinouts
Part Number: JD2D3-CDL-A (Red, DB-9 M-F) The serial loopback adapter is used for range
testing. During a range test, the serial loopback adapter configures the module to function as a
repeater by looping serial data back into the radio for retransmission.
Figure D‐01. Serial loopback adapter and pinouts
© 2007 Digi International, Inc. 56
XBee/XBee‐PRO ZigBee OEM RF Modules v1.x1x [2007.06.01] Development Guide
External Interface
B‐11c.
USB Port
B‐11b.
RSSI LEDs
B-11b. RSSI LEDs
B‐11a. RSSI LEDs indicate the amount of fade margin present in an active
I/O & Power LEDs
wireless link. Fade margin is defined as the difference between the
incoming signal strength and the module's receiver sensitivity.
Figure D‐03. Back View DIP Switch functions are not supported in this release. Future down-
loadable firmware versions will support the DIP Switch configurations.
B‐12a.
Reset Switch
B‐12a.
DIP Switch
© 2007 Digi International, Inc. 57
XBee/XBee‐PRO ZigBee OEM RF Modules v1.x1x [2007.06.01] Development Guide
X-CTU Software
NOTE: PC Setting values are visible at the bottom of the Range Test, Terminal and Modem Configura-
tion tabs. A shortcut for editing PC Setting values is available by clicking on any of the values.
Install
Double-click the "setup_X-CTU.exe" file and follow prompts of the installation screens. This file is
located in the 'software' folder of the MaxStream CD and also under the 'Downloads' section of the
following web page: www.maxstream.net/support/downloads.php
Setup
To use the X-CTU software, a module assembly (An RF module mounted to an interface Board)
must be connected to a serial port of a PC. The interface data rate and parity settings of the
serial port ("PC Settings" tab) must match those of the module (BD (Baud Rate) and NB (Parity)
parameters).
A terminal program is built into the X-CTU Software. Other terminal programs such as
"HyperTerminal" can also be used. When issuing AT Commands through a terminal program
interface, use the following syntax:
Figure D‐05. Syntax for sending AT Commands
© 2007 Digi International, Inc. 58
XBee/XBee‐PRO ZigBee OEM RF Modules v1.x1x [2007.06.01] Development Guide
NOTE: To read a parameter value stored in a register, leave the parameter field blank.
The example above issues the DL (Destination Address Low) command to change destination
address of the module to "0x1F". To save the new value to the module’s non-volatile memory,
issue WR (Write) command after modifying parameters.
© 2007 Digi International, Inc. 59
Appendix E:Additional Information
1-Year Warranty
XBee Series 2 RF Modules from MaxStream, Inc. (the "Product") are warranted against defects in
materials and workmanship under normal use, for a period of 1-year from the date of purchase. In
the event of a product failure due to materials or workmanship, MaxStream will repair or replace
the defective product. For warranty service, return the defective product to MaxStream, shipping
prepaid, for prompt repair or replacement.
The foregoing sets forth the full extent of MaxStream's warranties regarding the Product. Repair or
replacement at MaxStream's option is the exclusive remedy. THIS WARRANTY IS GIVEN IN LIEU
OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, AND MAXSTREAM SPECIFICALLY DISCLAIMS
ALL WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT
SHALL MAXSTREAM, ITS SUPPLIERS OR LICENSORS BE LIABLE FOR DAMAGES IN EXCESS OF THE
PURCHASE PRICE OF THE PRODUCT, FOR ANY LOSS OF USE, LOSS OF TIME, INCONVENIENCE,
COMMERCIAL LOSS, LOST PROFITS OR SAVINGS, OR OTHER INCIDENTAL, SPECIAL OR CONSE-
QUENTIAL DAMAGES ARISING OUT OF THE USE OR INABILITY TO USE THE PRODUCT, TO THE
FULL EXTENT SUCH MAY BE DISCLAIMED BY LAW. SOME STATES DO NOT ALLOW THE EXCLUSION
OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES. THEREFORE, THE FOREGOING
EXCLUSIONS MAY NOT APPLY IN ALL CASES. This warranty provides specific legal rights. Other
rights which vary from state to state may also apply.
Ordering Information
Figure E‐01. Divisions of the XBee/XBee‐PRO RF Module Part Numbers
X B 2 4 - B I T - 0 0
Contact MaxStream
Free and unlimited technical support is included with every MaxStream Radio Modem sold. For the
best in wireless data solutions and support, please use the following resources:
Documentation: www.maxstream.net/support/downloads.php
E-Mail. rf-xperts@maxstream.net
MaxStream office hours are 8:00 am - 5:00 pm [U.S. Mountain Standard Time]
© 2007 Digi International, Inc. 60