Aquavari Technical Solutions Pvt Ltd DOC NO - F-AQ-1.

1
Gat no. 49 Near Industrial Estate, Palus – 416 310. Sangli, Maharashtra

QUALITY ASSURANCE PLAN


STAGES Characteristics Quantum of Reference document Format of record REMARK
check
Review of chemical and mechanical properties One / Heat Approved data sheet Material test certificate P
RAW
MATERIAL UT on 25 mm plate thickness and above 100% ASTM A435 / ASTM NDT Report P
A578
Process / Welder Qualification 100% ASME SEC IX WPS / PQR / WPQ P
Visual 100% Component data sheet Inspection report P
IN PROCESS
Dimensions 100% Component data sheet Inspection report P
Stress relieving 100% ASME Sec VIII , div1 SR chart P
DP on 100 % Butt weld 100% ASME SEC V / E165 NDT Report H
FINAL UT on flange Butt weld 100% ASME E164, ASME Sec NDT REPORT
VII, DIV 1 APPENDIX-4 H
INSPECTION
Punching of Size and PN rating 100% Approved data sheet Inspection report P

LEGENDS
P To be performed by manufacturer
H To be performed by manufacturer in presence of customer

SGK RDM
PREPARED BY APROVED BY