Design & Simulation / Safety Instrumented Systems

Certain situations can lead to exceeding design limits.

By Andrew Sloley, Contributing Editor


Dec 03, 2012

The design basis for many pressure-vessel foundations includes sufficient capability to handle the load of the
vessel full of water. Designing to such a load enables hydrotesting the vessel full of water in one step after
modifications. No rule forces a plant to build a foundation to meet the full-of-water load requirement. However,
foundations for most storage vessels comply. It's normally expected that liquid will fill these tanks at some point.
Even if the design liquid is less dense than water, typical practice is to assume the vessel may be filled with
water.

Some foundations can't tolerate the load of a vessel completely full of water,
though. Most commonly, these less substantial foundations are used with “Less
large distillation towers. Such towers rarely are completely full during substantial
operation. However, upset conditions that create high liquid level may allow foundations
the load in a vessel to exceed foundation limits. are used with
large
Additionally, two other situations can create questions about acceptable distillation
foundation loads. Many older foundations included wood pilings. Monitoring
towers.”
may have shown damage to the pilings that limits allowable weight on them. In
addition, foundation design criteria have changed over time. What may have been suitable in the past no longer
may be judged sufficient. Standard practice is that an existing foundation that met requirements when built need
not be changed even if it doesn't satisfy current ones — so long as the structure's load doesn't increase by more
than a small amount. Despite this, a plant might choose to impose on critical equipment operating limits that
reflect the more stringent requirements.

1 of 5 5/25/2019, 9:06 AM
Is Your Vessel Foundation Really Strong Enough? | Chemical Processing https://www.chemicalprocessing.com/articles/2012/is-your-vessel-founda...

Figure 1. Safety instrumented system acts to prevent


high liquid loads that might overtax the foundation.

A large vacuum distillation tower (Figure 1) provides a recent example. It could exceed allowable foundation load
if the liquid level got too high. So, a fully independent level measurement has been added as a component of a
safety instrumented system (SIS). The SIS trips an interlock that shuts down the tower feed when the level rises
too high.

Also, the logic of the existing level controls has been augmented. It now includes alarms on the level and
procedures for operator action; addition of a duplicate bottoms level measurement using an alternative
technology (gamma ray) with voting for level control; auto-start of standby bottoms pumps; and automatic
alternative bottoms dispositions. These modifications aren't part of the SIS. However, they do count as
safeguards that make over-filling less likely.

High level stems from either too much into or not enough out of the tower. The unit and control system changes
all focus on ensuring the not-enough-out event doesn't occur. The new SIS controls address shutting down the
inlet flow if the outlet flow is too low despite all the modifications.

The crucial measurement for the SIS shutdown is differential pressure over the entire vertical height of the
vessel. This includes both liquid height in the bottom plus pressure drop across the tower. For a packed tower,
this is a reasonable approach. Increases in packing pressure drop boost liquid hold-up in the packed beds. More
liquid in the packed beds raises the weight on the foundation as well.

Pressure, whether differential or absolute, is given in force per unit area. Knowing the force, you can estimate the
weight on the foundation from liquid. At first glance, no correction for liquid density is required. This is true as
long as the tower has only one diameter. However, the situation becomes more complex in multiple diameter
towers. For the same force, a lower density liquid will have a higher level. Because the tower shown has a larger
diameter middle section, a higher liquid level increases the relative amount of the larger diameter that's filled.
Therefore, in this case, a less dense liquid will have more total volume for the same pressure. More total volume
ends up with more weight on the foundation.

Adding an appropriate margin to the differential pressure set point obviates using density corrections in the SIS.
Extra margin accounts for the effect of pressure drop and liquid volume in the different diameter packed beds.

Correct selection of instrumentation for the SIS achieved the desired safety integrity level. Damage or
modification to an existing structure or foundation certainly may demand modifications like this. However, the
better solution for a new vessel is to require the foundation to bear the water-filled load. One-time foundation

2 of 5 5/25/2019, 9:06 AM
Is Your Vessel Foundation Really Strong Enough? | Chemical Processing https://www.chemicalprocessing.com/articles/2012/is-your-vessel-founda...

costs are cheap compared to the installation and ongoing costs of a SIS.

ANDREW SLOLEY is a Contributing Editor to Chemical Processing. You can e-mail him at asloley@putman.net

Sign-up for design software from Sulzer Chemtech.

Safe design has long been a priority in the process industries. A safe design basis, together…

Past 7 Days Past 30 Days Past 6 Months

3 of 5 5/25/2019, 9:06 AM
Is Your Vessel Foundation Really Strong Enough? | Chemical Processing https://www.chemicalprocessing.com/articles/2012/is-your-vessel-founda...

General Information

Contact Us

Subscription Services

Editorial Guidelines

Vaaler Award Information

Media Kit

Editorial Calendar

Ask the Experts Forum

Process Puzzler

Cartoon Gallery

Online Polls

White Papers

Special Reports

eHandbooks

Videos

Podcasts

Products

Reliability-Centered Maintenance

4 of 5 5/25/2019, 9:06 AM
Is Your Vessel Foundation Really Strong Enough? | Chemical Processing https://www.chemicalprocessing.com/articles/2012/is-your-vessel-founda...

Meet the Editors

Meet the Editorial Board

Current Issue

Issue Archive

eNewsletters

Supplier Source Guide

Site Map

My Account

LinkedIn

Facebook

Twitter

YouTube

RSS Feeds

Contact Us | Advertise | Privacy Policy | Legal Disclaimers, Terms & Conditions


Copyright © 2004 - 2019 Chemical Processing. All rights reserved.
P: 630-467-1300 | 1501 E. Woodfield Road, Suite 400N, Schaumburg, IL 60173

Chemical Processing | Control | Control Design | Food Processing | Pharma Manufacturing | Plant Services | Smart Industry

5 of 5 5/25/2019, 9:06 AM

You might also like