You are on page 1of 10
afes ANMIT TEST AND CALIBRATION CENTRE ® (BIS /NABL ACCREDITED LABORATORY) conte T3888. 1258 To YOGICAB INSULATION PVT. LTD 548/A, Opp. Ganesh Petrol Pump, Rakenpur, Kalo-Gandhi Nagar Gujrat-382721 S.no. Description of Product 2C x2.5 sq.mm (96/0.30 mm) Flexible Copper conductor, Class -2, PVC Insulated & FR-LSH PVC Sheathed cable, 1100 Volts grade, Category C2, Cable Code YYOUSZ, 5 meters Copper wire dia 0.30mm for annealing test before stranding, Rupees: Twenty Two Thousand Four Hundred Sevety Two Only For “Amit Test and Calibration Centre” Bill No. 98 Bill Date: 07.06.2012 Service TaxNo.: AKKPA2590DS0001 PAN No.: AKKPA2590D Category of Service: Testing Inspection & Certification (ins) Qty Unit Price Amount 1 20000 20000 Sub Total 20000 Service Tax 2400 E Cess 48 SH. Cess 24 Total 22872 19/168, Sarai Rohilla, Old Rohtak Road, Near Shastri Nagar Metro Station & Usha Mata Mandir, Delhi-35 Tel. 011-23643995, Fax : 011-23643992, M.: 9582782444, Web: www.atncc.in, Emai info@atncc.in ASS AMIT TEST AND CALIBRATION CENTRE (BIS/NABL ACCREDITED LABORATORY) 19/168, Sarai Rohilla, Old Rohtak Road, Near Shastri Nagar Metro & Usha Mata Mandir, Delhi-110035, Tel. 011-23643995, Fax : 011-23643992 (M) 9582782444, Email: info@atncc.in; _amittestcc@gmail.com = cantata ne 1868 TEST REPORT (ELECTRICAL LABORATORY) ADDRESS OF THE LABORATORY 191168, Basti Sarai Rohilla, Old Rohtak Road, Near Usha Mata Mandir, Gurudwara Wali Gali, Delhi -110035 TELEGRAM TELEPHONE(S) 011-23643995, 011-23643992 FAX 011-23643992 E-mail info@atnce in TEST REPORT AS PER IS 694-1990 [WITH AMENDMENT NO{s} 5] REPORT NO : ATCC2012060501 05.06.2012 Issue To: Yogicab Insulation Pvt. Ltd. 548/A, Opp. Ganesh Petrol Pump, Rakanpur, Kalol - Gandhinagar, Gujrat - 382721 PART A. PARTICULARS OF SAMPLE SUBMITTED a) Nature of Sample PVC Insulated Cables for working voltages upto and including 1100Volts ) Grade/Variety/Type/Ciass/Size ete: 2C x 2.5 sq.mm (35/0.30 mm) Flexible Copper conductor, Class -2, PVC Insulated & FR-LSH PVC Sheathed cable, 1100 Volts grade, Category C2, Cable Code YYOUSZ, 5 meters Copper wire dia 0.0mm for annealing test before stranding, ) Declared Values, if any ) Code No. €) Batch No, & Date of Manufacture : f) Quantity 50 Meters g) Date of Receipt 01.05 2012 h) BIS seal INTACT/NOTINTACT/NOT-SEALED.NIL i) O's Signature Signed/-Unsigned NIL |) Any other Information/Expiry date, if any k) Date of Commencement of Testing 13.05.2012 1) Date of Completion of Testing 29.0 2012 m) Embossing 1609 YOGI CAB 2.5 SQ.MM 1.1KV [ISI] IS: 694 (MIL NO.-7335066 PART B : SUPPLEMENTARY INFORMATIONS. 2) Reference to sampling procedure, wherever applicable NA ») Supporting documents for the measurements taken and results derived like graphs, NIL tables, sketches and/or photographs, as appropriate to test report, if any(To be attached} ©) Deviation from the test methods as prescribed in relevant ISS/ work instructions, NIL ifany MANOHAR SINGH JADON 10f7 atcc AMIT TEST AND CALIBRATION CENTRE a. (BIS/NABL ACCREDITED LABORATORY) 19/168, Sarai Rohilla, Old Rohtak Road, Near Shastri Nagar Metro & Usha Mata Mandir, Delhi-110035, Tel. 011-23643995, Fax : 011-23643992 (M)_9582782444, Email: info@atncc.in; _amittestcc@gmail.com — TEST REPORT = commen 96 PART C: TEST RESULTS REPORT NO : ATCC2012060501 Is : 694-1980 S.No. TEST /CL. REF. ‘SPECIFIED REQUIREMENTS RESULTS 1_|Test on Conductor 1.1. |Nominal Size of Cable »mm? EG 2.54 Core Identification C1. 11.18 Table-7 12 Red & Black Red & Black Nature and Shape of Conductor . cl. ottable 1, C1.52.9,533 & Stranded 13 |6a1Tabie2 ofis8130:1904 Solid Stranded Copper Conductor Flexibility 14 cl 9.1 table 1, C14.1(a) of IS: 8130 :1984 Class-1/Class-2/Class-5 Class-2 15 [Oia of wire 030 No.of Wires in Conductor 3 (Min 16 |i 5.2.3 of IS: 8130 1984 36 [Annealing Test for Copper (Before |Wire Diameter Elongation Min Stranding) lover Up to and Cl. 15.1a ()8 Table-8, C1.6.1.2.1 of IS including 18130 : 1964 (ater stranding the testis 1.7. [under consideration) 1S: 10810(Part 1) mm mm Percent a8 I 021 90 loz1 oat 135 lost 136 * 180 36 me 25 Tensile strength For Aluminium ay ciset (vrais, C1 01 nnest30 ee OS wa Ci. 18.1 a (ipTable-8, Cl 6.2.10 a : 18 |1984 18: 10810(Part 2) mkuieg 180 Ni NA H4 Grade Above 150 Nimm? [Wrapping Test for Aluminium Conductor C1.15.1 a (ii)Table-8, Cl, 62.2 of IS 8130 1984 IS: 10810(Part 3) The wire should not Break NAL 19 Tested By

You might also like