You are on page 1of 1
Nasser S.Al-Hajri Corporation Sadara Chlorine Brine Project, Jubail-2, KSA SITE TECHNICAL QUERY [STQNo: q [Contract No: 110027, LSPB-1 Chiorine |STQ Date: 22/01/2013 |Addressed To: |Sadara/Jacobs Area |Chlorine From: Nasser S.Al-Hajri Corporation [Discipine: __|P-A7G Piping [Tea Nor [Above Ground piping (Subject: [Details for different test to be conducted in piping class \Reference: |NDT/PWHT/HT/PMI/FT REQUIERMENTS OF PIPE LINE CLASSES DETAIL DESCRIPTION OF DISCREPANCY /QUERY ‘The isometric drawing we received shows 100% RT for all field joints even for category D fluids .Also schedule Q requires ‘Advanced Ultrasonic Test forall joints at the same time in piping line Gasses species random RT. ‘We cannot find a consolidate specication regarding the NDE coverage. RECOMENDED RESOLUTION/ACTION BY NSH NSH understanding is tabulated referring all the available specification, please confi it’s correctness to finalize our NDE ‘tracking system, Cost Impact ] Latest Date for JACOBS Response ASAP. Schedule Impact == bebo ‘answer Rense PleceBs AS Por your SckEOOLE WE Be NOT USE CA OG o@ CASE (Anene omees ) Bor We Oo USE CAOS -~ can wor Gamo wire iT SAYS CROSS Buse 6© PWT cee you uetiey Witete Yor Got THAT IN@eMAnen Flom PLEASE | Colter? coor - GLOEw 2 We 8 woT USE Yerow OLP RCE * COLLET Pink = Coadert TD Sec ‘Answered By: Discipline Lead ian Cue | Approved By moe Sin Lay me Printed pate:22/01/2019 3:56:35 mt age 1 of 3 NSK-SCB-L--008, REV-0, O1-nug-2012 Field Technical Services Manager Charlie ardey