You are on page 1of 3
AT FAL September 1995 Supersedes Descriptive Bullotin 41-5308, pages 1-2, dated November 1990 Males to: €, 0, ci41-5008, ‘ABB Power T&D Company Inc. Relay Ovision seal oral Springs. FL Allentown, PA Device Number: 81 Descriptive Bulan 41-5308, Page 1 CIRCUIT 8 SHIELD ° Type 81 One and Two Step Frequency Relays Features ‘High accuracy # Easy 0 set * Low burden 1 High seismic eapabity 69 ZPA # Transient immunity ‘Availabe in one stage or two stage mode's © 2year warranty © UL Recognizes Application ‘The Type 81 Frequency Relay is a reliable sold state olay designed to provide accurate detection of abnormal frequency conatons on ‘ectical power systems. The Type 81 is favalable in one stage and two stage model Single step models are provided with moans to select either underkequency oF overequency ‘operation. Two stage macels may be set up lor ‘ether two stops of undertrequency detect, {wo steps of overtaquoncy detection or for ‘verrequency and underireguency protection ‘The relay has operating characterises which ‘make it deal for application on clesely Coordinated system load shodding programs. The accuracy and stability of the relay characteristics permis setings much closer to system frequency. ang clase steps between Settings of relays ina load shedding program, than possible with electromechanvcal relays ‘Another application is typical 0 large indus plants which have some local generaton. Normally, ney depend on ate line with 2 Luly foF some portion of thet power needs, the te breaker atthe tity end shoud apen, the generator n the plant woule be overloaded especialy iit also altempls to pek up uty Toad tapped on the te ne. This averoad causes and undertrequency condition onthe industria system. The Type 81 can be used 10 ‘pen the tie to the tity system and arop non essential load, Essential lads can be maintained tothe Int ofthe generator capability. In. DSG applications, typical protection inckudes atmo step Type 81 providing an under and overroquancy window and a Type 27°59, providing an under and overvoltage window ‘The relay uses digital counting techniques to provide an accurate measure of requency. TRE time base measurement is provided by an gxtromely stable crystal oscilatorreterence ‘The set point accuracy ‘80.008 Hz. The relay 's provided win TRIP POINT and TIME DELAY settings. These settings are easly made on the {font panel ofthe relay. For underrequercy ‘operation the time delay periog begins when the relay has counted three consecutive cycles below the trp trequency. Tha time delay counter wil be fully reset it one cyce odcurs above the tp requency, Desexptve Bullet 41-5308 Page 2 Specifications Operating Range: Input Circuit Rating: Undervottage Cutoff Function: Burden: Control Power: Operating Time: Output Contacts: Output Circuit Rating: Target ceil mating Temperature: ‘Seismic Capability: ‘Transient immunity: Dielectric: Weight: Volume: How to Specify Models availabe for 48-52 He 54.63 He 60-140 Vac Adjustable 60 - 100 vols Factory set at 60 vols 07 VA Mode's availabe for: 48/125 Voe @ O.O7A, 48/110 Vdc @ 0.078 24892, Vac @ 0.11A,1107220 Veo @ 007A 250 Vde @ 0.064 ‘Adjustable 1 - 99 cycles (must have 3 consecutive incorrect cycles betore timing begins) 2 Form C contacts fort stop unit) 1 Form C contact for each step (for 2 step unit) @ 125 Vee 308 tipping BA continuous ‘A opening resistive (0.38 opening inductive 30.Amp Tripping (1 Amp minimum trp cel current required to set targets). For tip cveut eurents below 1 Amp, 25. ‘Amps minimum, add “ST to catalog rhumber for sensitive target col. Mirus 20 to Plus 70°C ‘More than 69 ZPA biaxial mul-foquency vibration without damage or maltunction (ANSITEEE C37 98) More than 3000 V, 1 MH bursts at 60 Hz repetition rate, coninuous (ANS! C37.908, 1974}; fast transient test; EMI immunity 2000 Vac RMS, 60 seconds all circuits to ‘round 1 Step Unboxed «37 tbs (1.7 Ks) Boxed 43 bs (2.0 Ko) 2 Step Unboxed -3.9 Ibs (1.8 Kg) Boxod - 46 bs (2.1 Ko) 0.26 cubic teot ‘Typleal Connections—t Step Relay ae 42 Ty ‘Typical Connections—2 Step Relay Frequency Relay shall be Asea Brown Boveri “Type 81 oF approved equal. Relay operating pola shal be Settable 90.05 Hz incremens. Time delay shal be adjustable in 1 oyie incre ‘ments. Relay shal be capable of withstanding 69 ZPA seismic stress without malunctons. (Operation indicator shall be provided. An Undervotlage cutot function Shall be provided to block operation for low ine votage conaitions. How to Order For a complete isting of avaiable frequency relays, soe TO 41-025, To place an order, ofr futher information contact your nearast ABB Representative. Further Information st Pros: PL 41.020 Technical Data: TD 41-025 Inetracton Book: IB 7.4.1.7-5 Other Protective Relays: ‘apiecaton Select Guide, TO 41-016 ‘September 1995 ABB Power T&D Company, Inc Relay Diision DED Gaal Sprngs, FL Allentown, PS June, 1994 Supersedes Descrptive Bulletin 41-5308, Page 3, dated Novernber, 1900 Maled 1: F, D, 6181-5008, Descriptive Bullet 41-5308, Page 3 CIRCUIT 8 SHIELD * Type 81 One and Two Step Frequency Relays ope Toe toni for waste ‘ema Catalog aonetions emt TOR 701275 weno Ve aaze0s 2032 Woe 2281295 a5 de az201275. seo Vex a200 205, = ove aez0 1055 810 Ve 2201206 Bane Vee ——aaaC206 280 vac 42201256 SBt10 de 228 1206 280 ve ~ar26 1256, © Forcther conto veges contact he neres ABB Represoniave ‘To place an order, oF for further information, contact the nearest ABB Representative, Internal Conne iagrams Note: Reter to Instruction Book IB 7.41.75 for contact logic data 160422A__Type.st One-Stop Frequency Y Drawout Test Case eames rer § OTe eA “Ta on Ss Su Bn Be Bu Su owe 1604228_Type st ‘Two-Step Frequency Relay ‘Drawout Test Case

You might also like