PLAN LP OF GUTTER GUTTER FLOW LINE NOTE: IF SIDEWALK IS EXISTING, A SECTION MAY BE SAW CUT AT WEAKENED PLANE POINTS TO PLACE 3” PVC & WWF WWF 4"X4"—10/10 FLOW LINE OF PIPE 5" ABOVE FLOW LINE OF GUTTER 1.5% M SECTION A 2" CLEAR FROM TOP OF PIPE S10 + CLASS 2 AGGREGATE BASE A 1” CLEAR FROM, TOP OF WWF WWF 4°x4"—10/10 CLASS 2 2c 3” PVC PIPE SECTION B-B AGGREGATE BASE VARIABLE SIDEWALK WIDTH NOTES: LOCATION OF SIDEWALK DRAINS ARE APPROXIMATE AND MAY BE CHANGED BY THE ENGINEER AS REQUIRED BY SITE CONDITIONS. SIDEWALK DRAIN TO BE 3” SCHEDULE 40 HEAVY WALL RIGID POLYVINYL CHLORIDE PIPE OR APPROVED EQUAL. IF MORE THAN ONE DRAIN PIPE IS PLACED, WIDEN WIRE MESH PLACEMENT AND CONCRETE KEYWAY ACCORDINGLY. COUNTY OF SONOMA DEPARTMENT OF TRANSPORTATION AND PUBLIC WORKS SIDEWALK DRAIN DETAIL DATE: MAY 2004 _|REVISED: JULY 2018 APPROVED BY: ‘SCALE:[DRAWING NO.