You are on page 1of 2
Minutes of Meeting — 1% June 2019 UTKAL Fismidth Krebs Mr Surender Kumar Kunal Kothari Mr RameshChandra Duwada Nitin Saxena Reference: - Mill Slurry Pump, 232-PU-102A FLS Krebs team visited Utkal site on 29" May to 1* June 2019 to ascertain and review the performance of mill MAX 6x4-21 High Head pump supplied against the PO Number 91102209. Krebs mill MAX Pump was commissioning on 24/2/2019 at relay tank and Pump serial Number is 17168. 1. It is acknowledged that during 1* month of commissioning power draw was 20-30% lower than existing equipment for the same duty condition. 2. Data taken from DCS clearly indicates that the flow pumped from Krebs mill MAX pmp is higher than the existing installations, There are instances where the flow of the pump has been over 300 m3/h which is 30% higher than design capacity. Considering the higher flow of 130% over design, the power reading is accordingly higher and cannot be compared to the power readings of flow of 250m3/h of existing installation. ‘These readings are based on the data after correcting the flowmeters and current readings in both the DCS and the panel at the field, 3. Enclosed is the data of operational parameters collected since pump commissioning from DCS for records. Based on data below, Krebs ‘mill MAX pump is drawing 9-10% lower amps at 135 m3/h and gradually upto 30% at 250 m3/h PU232-102A FLS Krebs Pump, Model mill AX 6x4-22 si Motor: 7 No. RPM | Motor Current at DCS | Motor Current at VFO | Flow Remarks % Amps Amps | mah 1 55 102 99 134.7 | Slurry SG - 1.79 g/cc 2 o | 18 14 260 3 65 130 128 270 | Pumping 3 pumps 4 70 150 7 274 | in PDS 5 75 170 166 300 6 85 218 215 335 7 so | 246 242 354 PU232-1028 Metso Pump, Model HM150 si ~ | Motor T No. i RPM Motor Current at DCS Motor Current at VED_| Flow Remarks % Amps m3/h | TI ] 2 60 101 13 | 3 65 109 133 | Pumping 2 pumps 4 70 119 154 | in PDS 5 75 130 170 6 Bs | 156 200 7 | 173 228 i

You might also like