You are on page 1of 19

इंटरनेट मानक

Disclosure to Promote the Right To Information


Whereas the Parliament of India has set out to provide a practical regime of right to
information for citizens to secure access to information under the control of public authorities,
in order to promote transparency and accountability in the working of every public authority,
and whereas the attached publication of the Bureau of Indian Standards is of particular interest
to the public, particularly disadvantaged communities and those engaged in the pursuit of
education and knowledge, the attached public safety standard is made available to promote the
timely dissemination of this information in an accurate manner to the public.

“जान1 का अ+धकार, जी1 का अ+धकार” “प0रा1 को छोड न' 5 तरफ”


Mazdoor Kisan Shakti Sangathan Jawaharlal Nehru
“The Right to Information, The Right to Live” “Step Out From the Old to the New”

IS 15285 (2003): Sensory Analysis - Methodology -


Initiation and Training of Assessors in the Detection and
Recognition of Odours [FAD 16: Foodgrains, Starches and
Ready to Eat Foods]

“!ान $ एक न' भारत का +नम-ण”


Satyanarayan Gangaram Pitroda
“Invent a New India Using Knowledge”

“!ान एक ऐसा खजाना > जो कभी च0राया नहB जा सकता ह”


है”

Bhartṛhari—Nītiśatakam
“Knowledge is such a treasure which cannot be stolen”
IS 15285:2003
.
ISO 5496:1992

Indian Standard
SENSORY ANALYSIS—METHODOLOGY—
INITIATION AND TRAINING OF ASSESSORS IN THE
DETECTION AND RECOGNITION OF ‘ODOURS

ICS 67.240

(3 BIS 2003

BUREAU OF INDIAN STANDARDS


MANAK BHAVAN, 9 BAHADUR SHAH ZAFAR MARG
NEW DELHI 110002

February 2003
Price Group 7
Food Analysis and Nutrition Sectional Committee, FAD 58

NATIONAL FOREWORD

This Indian Standard which is identical with ISO 5496:1992 ‘Sensory analysis— Methodology— Initiation
and training of assessors in the detection and recognition of odours’ issued by the International
Organization for Standardization (ISO) was adopted by the Bureau of Indian Standards on the
recommendation of the Food Analysis and Nutrition Sectional Committee and approval of the Food and
Agriculture Division Council.

In the adopted standard, certain terminology and conventions are, however, not identical to those used
in Indian Standards. Attention is drawn especially to the following:

a) Wherever the words ‘International Standard’ appear referring to this standard, they should
be read as ‘Indian Standard’.

b) Comma (,) has been used as a decimal marker while in Indian Standards, the current practice
is to use a point (.) as the decimal marker.

In this adopted standard, the following International Standards are referred to. Read in their respective
place the following:

International Standard Corresponding Indian Standard Degree of


Equivalence

ISO 6658:1985 Sensory analysis— IS 6273 Guide for sensory evaluation of Related
Methodology —Generalguidance foods :
(Part 1) :1971 Optimum requirements
(Part 2) :1971 Methods and evaluation
cards
(Part 3/See 1): 1983 Statistical analysis of
data, Section 1 Difference/preference tests
(first revision)
(Part 3/See 2) Statistical analysis of data,
Section 2 Ranking and scoring tests (first
revision)

ISO 8589:1988 Sensory analysis— IS 15316 : 2003 Sensory analysis— Identical


Methodology—General guidance General guidance for the design of test
for the design of test rooms rooms

For the purpose of deciding whether a particular requirement of this standard is complied with, the final
value, observed or calculated, expressing the result of a test or analysis, shall be rounded off in accordance
with IS 2:1960 ‘Rules for rounding off numerical values (revised)’. The number of significant places
retained in the rounded off value should be the same as that of the specified value in this standard.
IS 15285:2003
ISO 5496:1992

Indian Standard
SENSORY ANALYSIS—METHODOLOGY—
INITIATION AND TRAINING OF ASSESSORS IN THE
DETECTION AND RECOGNITION OF ODOURS

1 Scope 4 Products

This International Standard describes several types


of method for determining the aptitude of assessors 4.1 Water, neutral, tasteless, still and odourless.
and for training assessors to identify and describe
odoriferous products.
4.2 Ethanol, 96,9 0/0 (VIP’), free from extraneous
The methods described in this International Stan- odours, even in low concentrations.
dard are suitable for use by the agri-foodstuffs in-
dustries and industries employing olfactory analysis
(e.g. perfumery, cosmetics and aromatics). 4.3 Other suitable media, appropriate to the re-
quirements of the industry concerned.

2 Normative references 4.4 Odoriferous substances, as pure as possible:

The following standards contain provisions which, a) substances chosen from those given in
through reference in this text, constitute provisions table A,2, and used at the concentrations pro-
of this International Standard. At the time of publi- posed, andlor
cation, the editions indicated were valid. All stan-
dards are subject to revision, and parties to b) any other substance deemed to be of interest,
agreements based on this International Standard depending on the aim of the test or the require-
are encouraged to investigate the possibility of ap- ments of the industry concerned.
plying the most recent editions of the standards in-
dicated below. Members of IEC and ISO maintain For the training phase, the collection of odours shall
registers of currently valid International Standards. comprise odoriferous substances representative of
several groups of odours (e.g. terpinic, floral) and
ISO 6658:1985, Sensory analysis – Methodology – substances which the assessors will examine (to
General guidance. determine that the assessors have no anosmia for
these substances).
ISO 8589:1988, Sensory ana/ysis – General guidance
It is also advisable to include odours representative
for the design of test rooms.
of certain defects (e.g. odours typical of cleaning
products, printing inks) which are likely to be en-
countered by the assessors in the forthcoming
evaluations.
3 Principle
Odoriferous substances serving as references shall
Presentation to the assessors of odoriferous sub- be chosen from among those having a stable com-
stances in various forms and concentrations, in ac- position and which can be stored for an acceptable
cordance with the procedures specified in this length of time without deterioration. These sub-
International Standard. stances shall be stored in a cool place (around
+ 5 “C) and protected from air and light.
Assessment and identification by the assessors of
the odours given off by these substances and re- NOTE 1 When in aqueous media, the aromatic power
cording of the results. of certain substances increases with dilution.

1
IS 15285:2003
ISO 5496:1992

5 General test conditions 6.1.1.2 Substances

6,1.1.2.1 Odoriferous substances, chosen for ex-


5.1 Test room ample from table A.2, at the specified dilution.

The tests shall be carried out in a room meeting the


6.1.1.3 Apparatus
requirements specified in ISO 8589,

Special precautions shall be taken to remove odours 6.1.1.3.1 individual tinted glass flasks, of sufficient
from the test room as much as possible (e.g. by capacity to hold the products to be tested (generally
ventilation). between 20 ml and 125 ml) and to leave sufficient
head space to permit equilibrium of the vapour
pressure, equipped with unlubricated ground glass
5.2 General test rules stoppers.

In addition to the general rules which apply to Alternatively, beakers, fiHed with a watch-glass, or
assessors involved in any sensory analysis and suitable disposable containers, sold commercially.
given in ISO 6658, the assessors participating in If plastics apparatus is used, it is essential to check
these tests shall not have carried out any other that it is made of an odour-free material which does
sensory analysis concerned with the detection or not absorb odours and which bears no chemical af-
assessment of odours or odoriferous compounds finity with the substances under test.
within the 20 min prior to the test,
6.1.1.4 Preparation of sampies
To avoid tiring the assessors, it is recommended
that no more than 10 odoriferous substances are
Where necessary, prepare in accordance with the
presented to them per session,
instructions given in A.2 suitable dilutions of the
substances used to obtain the appropriate concen-
6 Methods trations given in table Al.

Prepare the samples at least 30 min before the test,


The olfactory assessment can be carried out by di-
to allow time for the vapour pressure to reach equi-
rect methods or by retro-nasal methods.
librium at ambient temperature, as follows.
There are currently three direct methodsl) of smell-
Code the flasks and stoppers,
ing, i.e.
Piace the appropriate quantities of the substances
— assessment of odours in flasks (6,1,1); prepared in the coded flasks, taking care to leave
sufficient head space in the flasks.
– assessment of odours on smelling strips (6.1.2);
The substances are poured directly into the flasks,
— assessment of encapsulated odours (6.1.3); placed on a medium (e.g. cotton or absorbent paper)
which is aiready in the flasks, or blended with a
and two retro-nasal (or pharyngo-nasal) methods of medium (e.g. fat),
smelling, i.e.
Close the flasks with the glass stoppers or watch-
— assessment of odours in the gaseous phase glasses,
(6.2.1);
6.1.1.5 Procedure
— assessment of odours by ingestion of aqueous
solutions (6.2.2). Present to each assessor the series of flasks pre-
pared, instruct the assessor to carry out the evalu-
6.1 Direct methods of smelllng ation as follows.

The assessor opens the flasks one by one and, with


6.1.1 Method of assessing odours In flasks the mouth closed, sniffs the vapour phase in order
to identify each odoriferous product. There is no
6.1.1.1 Principie strict methodology, provided that the assessor
smells all the flasks at suitable intervals in the same
Presentation to the assessors of a series of flasks way, e.g. in short sniffs, or deep breaths, etc. Once
containing different odoriferous substances at given a decision has been made, the assessor closes the
concentrations, flask and replies to the questions on the answer

1) The assessment of odours using an olfactometer is not considered in this International Standard as it is not used in
initiation and training.

2
IS 15285:2003
ISO 5496:1992

form (see clause 7), (See thespecimen answer form The strip shall not be over-impregnated with sol-
in annex B.) ution; the migration front of the liquid shall be be-
tween 5 mm and 10 mm from the bottom end of the
NOTE 2 Depending on whether the assessors are strip.
undergoing the initiation phase orthe training or selection
phase, they may or may not be permitted to smell each Place the prepared strip on the strip-holder or pick
product several times, or to return to previously examined it up with the tweezers (6.1.2.3,2), taking care that
flasks. the strips do not come into contact with each other.
Leave the strips for a few seconds to allow any
6.1.1.6 Interpretation of results evaporation of the solvent to occur.

Interpret the results in accordance with clause 8. 6.1.2.5 Procedure

6.1.2 Method of assessing odours on smelling Hand the prepared strips to the assessors and in-
strips struct them to proceed as follows.

The assessor performs the assessment of the odour


6.1,2.1 Principle by sniffing the smelling strip, waving it gently a few
centimetres from his/her nose. The strip shall under
Presentation to the assessors of a series of smelling no circumstances touch the nose, a moustache or
strips impregnated with odoriferous substances. the skin.

NOTE 3 Because of evaporation, the odour is only fully


6.1.2.2 Substances released for a limited period of time, depending on the
odoriferous substance.
6.1.2.2.1 Odoriferous substances, chosen for ex-
ample from table A.2, at the specified dilution, Once a decision has been made, the assessor dis-
cards the strip and replies to the questions on the
answer form (see clause 7). (See the specimen an-
6.1,2.3 Apparatus swer form in annex B.)

6,1.2,3.1 Smelling strips, i.e. small strips of filter- It is essential that the strips are collected and dis-
paper, of variable porosity depending on the manu- posed of after use in a sealed container, so as not
facturer, and of various shapes (rounded, bevelled, to saturate the atmosphere of the test room and thus
etc.)z), with a mark at the bottom between 50 mm to interfere with subsequent assessments.
100 mm from the end.
The assessor then goes on to examine the next
substance.
6.1.2.3.2 Strip-holders or tweezers, made of an
odourless material.
6.1.2,6 Interpretation of results

6.1.2.3,3 Tinted glass flasks, of suitable capacity for Interpret the results in accordance with clause 8.
holding the odoriferous substances (one flask per
substance).
6.1.3 Method of assessing encapsulated odours

6.1.2.3.4 Droppers (optional).


6.1.3.1 Principle

6,1,2.4 Preparation of samples Presentation to the assessors of a series of micro-


encapsulated odoriferous substances.
Prepare, in accordance with the instructions given
in A.2, stock solutions of the substances used,
6.1.3.2 Substances
Prepare one substance at a time and place in a
flask. 6,1,3.2.1 Odoriferous substances, chosen for ex-
ample from table A.2, at the specified dilution,
Rapidly dip the bottom ends of the strips (6,1.2.3,1)
(for each of the assessors) one by one, in the flask
up to the mark or, preferably, using a dropper 6.1,3,3 Apparatus
(6.1.2.3.4), place a drop of the substance on the bot-
tom end of each strip, 6.1.3.3.1 Encapsulated odoriferous substances,

2) The names of suppliers can be obtained from manufacturers of aromatic products.

3
IS 15285:2003
ISO 5496: 1992

available commercially), such as encapsulated 6,2,1.2 Substances


odours on paper supports which are to be
scratched, or on labels which are to be torn, etc. 6.2.1.2.1 Odoriferous substances, chosen for ex-
ampie from tabie A,2, at the specified diiution.
6.4.3.4 Preparation of samples
6.2.1,3 Apparatus
No preparation is required since the samples are
ready for use. The apparatus shali be made of giass (preferably)
or piastics material. if piastics apparatus is used, it
is essentiai to check that it is made of an odour-free
6,1.3.5 Procedure materiai which does not absorb odours and which
bears no chemicai affinity with the substances under
Present the samples, one at a time, to the assessors test,
and instruct them to proceed as follows.
6.2.1.3.1 Beakers, of minimum capacity 100 mi.
The assessor follows the manufacturer’s in-
structions for releasing the odoriferous substance.
The odour is then judged by the assessor using the 6.2.1.3.2 Piastics films, odourless and non-
same procedure as for the smelling strip method absorbent,
(6.1.2.5).
6.2.1 .3.3 Straws.
NOTE 4 With this presentation, re-assessments of the
odours are not possible.
6.2.1.4 Preparation of sampies
Once a decision has been made, the assessor dis-
Where necessary, prepare in accordance with the
cards the support and replies to the questions on the
instructions given in A,2 suitabie diiutions of the
answer form (see clause 7). (See the specimen an-
substances used to obtain the appropriate concen-
swer form in annex B,)
trations recommended in table Al,
(t is essential that the micro-capsules are collected
Prepare one substance at a time.
and disposed of after use in a sealed container, so
as not to saturate the atmosphere of the test room Place 50 mi of the prepared dilutions in the beakers
and thus interfere with subsequent assessments, and cover with piastics fiim.

The assessor then goes on to examine the next


substance. 6.2.1,5 Procedure

Give the beakers, one at a time, to the assessors


6.1.3,6 Interpretation of results and instruct them to proceed as foiiows.

The assessor pierces the piastics film with the


Interpret the results in accordance with clause 8
straw, The assessor then inhaies through the mouth
the gaseous atmosphere above t~e iiquid and
exhales heaviiy through the nose. Under no circum-
6.2 Retro-nasal methods of smelling stances shall the straw touch the iiquid, if this hap-
pens by accident, give the assessor another beaker.

6.2,1 Method of assessing odours in gaseous The assessor identifies the odour and repiies to the
phaseeb questions on the answer form (see clause 7). (See
the specimen answer form in annex B.)

6.2.1.1 Principie The assessor then goes on to assess the next sub-
stance.
Assessment of odoriferous substances in the
gaseous phase by inhalation of the gaseous phase 6.2.1.6 interpretation of resuits
into the buccal cavity and assessment of the odour
by retro-nasal means. interpret the results in accordance with clause 8.

3) Series of ready-to-use micro-encapsulated odours are availabie commerciaiiy, but some manufacturers can provide
these micro-capsules to order. It should, however, be noted that this type of presentation is at present fairly expensive.
4) There is another method for assessing odoriferous substances in the gaseous phase which consists of placing smeiiing
strips impregnated with the odoriferous substances inside the buccai cavity. This method is, however, difficult to implement
with novice assessors and has to be reserved for use with trained paneis, it is described in annex C for information.

4
IS 15285:2003
ISO 5496:1992

6.2.2 Method of assessing odours by ingestion of 6.2,2.6 Interpretation of results


aqueous solutions
Interpret the results in accordance with clause 8

6.2.2.1 Principle
7 Answer form
Presentation to the assessors of a series of beakers
containing different odoriferous substances. The following questions appear on the answer form,

Assessment of the retro-nasal olfactory sensation Do you perceive an odour?


produced by the substances following ingestions).
Do you recognize this odour?

6.2.2.2 Substances The assessor is also asked to name or describe the


odour or to make an association.

6.2.2.2.1 Odoriferous substances, food grade, cho- In addition, it is useful to leave a space for remarks
sen for example from table A.2, at the specified di- by the assessors.
lution.
NOTE 6 The answer form may be in printed form (as
shown in the example in annex B) or in electronic form.
6.2.2.3 Apparatus

8 Interpretation of resuits
6,2,2.3.1 Individual beakers, fitted if possible with a
lid and a straw, The results are interpreted in different ways by the
test supervisor depending on the aim of the test and
whether the tests are for the purpose of instruction
6.2,2.4 Preparation of samples
(or initiation), training or selection of assessors.
Where necessary, prepare in accordance with the The requirements regarding the correct designation
instructions given in A,2 suitable dilutions of the of the substances also depend on the purpose of the
substances used to obtain the appropriate concen- test.
trations recommended in table Al.
The correct reply to the instruction to name or de-
NOTE 5 In this method, the solutions are far IWSS con- scribe the odour or to make an association varies
centrated than in the direct smelling method. as follows, depending on the case:

Pour the dilutions into the beakers and fit the lid if a) at the introductory stage, the reply may be the
used. chemical name (where this is known), the com-
mon name, or an association or even an appro-
priate descriptive expression;
6.2.2.5 Procedure
b) at the training or selection stage, the reply may
Present to each assessor the series of beakers pre-
be the chemical name or the appropriate de-
pared and instruct them to proceed as follows.
scriptor.
If the beakers are not covered, the assessor pinches
his/her nose, drinks a mouthful of the solution and 8.1 introduction — initiation
then releases the nose when the solution is in the
mouth as soon as the beaker has been removed. Once the assessors have recorded their evaluations
The assessor swallows the solution. The odour is on the answer form, the test supervisor shall call
assessed during the subsequent expiration. If them together and give the results, designating each
beakers with lids and straws are used, it is not substance by its chemical name or descriptor.
necessary for the assessor to pinch his/her nose.
The supervisor shall make the substances available
The assessor thus makes the assessment of the to the assessors and reply to any questions raised
odour by retro-nasal means in order to help them to memorize the association
between the chemical substance and the corre-
Once a decision has been made, the assessor re- sponding odour.
plies to the questions on the answer form (see
clause 7). (See the specimen answer form in Several sessions are required for teaching the
annex B.) assessors to recognize a large number of odours.

5) Under normal conditions of consumption, a mouthful of product also permits the flavour as a whole to be assessed.

5
IS 15285:2003
ISO 5496: 1992

There is no marking of the assessors, but the Following repeated assessments, the progress in
supervisor may at this stage make observations re- the performance of each assessor and the effec-
garding suspected cases of anosmia, tiveness of the training shall be judged.

8.2 Training 8.3 Selection

At the training stage, the test supervisor analyses The information on performance gained during the
the answer forms, examining the replies of each training period shall form the basis for the test
assessor, supervisor to eliminate those assessors who have
made repeated errors,
In this training phase, the assessors shall identify
the substance by its chemical name or descriptor. The information can also be used to set up special-
ized groups adapted to various specific problems.
IS 15285:2003
ISO 5496:1992

Annex A
(normative)

Preparation of dilutions of odoriferous substances

A.1 Apparatus A.2.3 Preparation of further dilutions

See tabie A.1.


A,l.1 Glass pipettes, preferably disposable, for the
preparation of the diiutions.
A.3 Examples of odoriferous substances
A.2 Preparation of diiutions that can be used for training in the
detection and recognition of odours
A.2.1 Preparation of the stock solution (SS)
See table A,2.
Take 1 g of the substance and make up to 100 g with
the ethanoi (4.2). Table A.2 also gives the number of dilutions to be
used depending on the method of preparation of the
sampies
A.2.2 Preparation of the working solution
(Ws)
Take 1 g of the stock soiution (SS) and make up to
100 g with the ethanoi (4.2).

Tabie A.1 – Preparation of dilutlons


Concentration
Dilution No. Preparation
(g/l)

,.-s
f 0,1 g of working solution (WS) made up to t I of water
2 0,5 g of working solution (WS) made up to t I of water 5x 10’-5
,.-4
3 Ig of working solution (WS) made up to 1 I of water
4 5g of working solution (WS) made up to 1 I of water 5 X10-4
,..3
5 10 g of working solution (WS) made up to 1 I of water
6 50 g of working solution (WS) made up to t I of water 5 X10-3
7f) lg of stock solution (SS) made up to 1 I of water 10 2
81) 5g of stock solution (SS) made up to 1 I of water 5 X10-2

1) it is necessary to dilute the stock solution directly to obtain an ethanol concentration of less than 2 “A (m/m) in the
final solution.

7
IS 15285:2003
ISO 5496: 1992

Table A.2 — Examples of odoriferous substances that can be used for tralnlng in the detection and recognition
of odours
Dilution No. from table A.1 to be useds)

Chemical name or Molecular Descriptor of odour Direct method Retro-naaal method


No.
abbreviationll formulaz) or association
Smelling Gaseoua
Flasks Ingestion
strips phase
- 1

1 d-Limonene C,0H18 lemon, orange zest


161
I 1 SS 1715
1 I
2 I Citral C10H180 fresh, lemon 5 Ss 6 4
I I I 1
C10H180 rose 5 Ss 6 4

I I
crushed grass, green
CgH,20
beans
6 Ss 7 5
—. I I
C7H~0 bitter almond 6 Ss 7 5

rancid butter,
CgHaOz 5 Ss 13 4
cheesy, sour milk

C~H1z02 banana, strawberry –4 Ss 5 3

floral, lily of the val-


8 Benzyl acetate C9H100, 5 Ss 8 6
ley, jasmin, lilac
I I I I
C11H2002 fruity, peach 6 Ss 7 5

floral-scented clean-
C$HIOO 8 Ss 8 7
ing substance, rose
1 I 1 I
C8H9N02 orange blossom 4 Ss 5 3
I 1 1 1
12 Ethyl phenyl acetate C10H1202 apricot, honey 4 Ss 5 3
——
aniseed, aniseed-
13 Anethole C10H120 3
tlavoured aperitif
‘s T
I I I
14 Cinnamaldehyde C9H80 cinnamon 6 Ss 7--F=---

15 Vanillin C8H80j vanilla 5 Ss 6- 4


=
C10H200 mintd) 6 Ss 8 6
7
C,2H2002 spicy, pine
141 SS 1513

18 Thymol CIOH1qO

Ct~H2~
spicy, fresh thyme,
grass

carrot, woody
r7’m 3
161
t 1 SS 1715
i
c15H240 woody, sandalwood —4 Ss
5-l-=-
C,0H1202 cloves 14 ISS 1513
22 1-Octen-3-ol CeHteO mushroom
141 SS 1513
IS 15285:2003
ISO 5496:1992

Dilution No. from table A.l to be useds)


I
Chemicsl nsmeor Molecular Descriptor of odour Direct method I Retro-nasalmethod I
No.
abbreviation!) formulaz) or association

I I I I
Smelling Gaseoua
Flasks Ingestion
strips phase

23 2- Methylisoborneol musty 3

mashed potato,
24 Methional C,H80S grilled onion, grilled 5 Ss 6 4
meat

1) It isnecessary to use products which are as pure as possible since impurities can modify the nature and intensity I
of the odour.
2) Seethe detailed formulae given intable A3
3) The concentrations specified have been chosen after practical tests with all Ihesubstances given inthe table using
panels of inexperienced assessors. The concentrations chosen correspond to the recognition threshold of70 ‘A of the
assessors,
4) Also produres a sensation of cold.

Table A.3 — Detailed formulae of odoriferous substances

No, Chemical substance Detailed formula

1 Mirnonene

\
O
CH1–C=CH2

2 :itral (neral + geranial)

Nerul


3 Seraniol
CH~

T
\ CH20H

(
H3C CH3

4 cis-3-Hexen-l -01
CH3—CHZ—CH=CH–CH2–CH20H

5 Benzaldehyde

0\ / CH’

9
IS 15285:2003
ISO 5496: 1992

No. Chemical substance Detailed formula I

6 Butyric acid
CH3CH2CH*COOH

7 Ethyl butanoate
tHj–CHz-CH2-[00 –[H2-CHJ

8 Benzyl acetate

CH#OOCH3
\/
o-

9 y-Undecalactone

n PO
CH3[CHJ~CH2

10 2-Phenylethanol
~ CH2- [H20H
I
0 /

11 Methyl anthranilate
NH2

\ / Coot”’
G

12 Ethyl phenyl acetate

// CH2–CO&_CHcCH3
o- —

13 Anethole

“c” o-
\ / C= CHCH3

14 Cinnamaldehyde

\/
o CH=CHCHO

15 Vanillin
CHO

:1
0CH3
o
OH

16 /-Menthol (H3

OH
Q
HIC tH3
IS 15285:2003
ISO 5496:1992

No. Chemical substance Detslled formuls

17 Terpinyl acetate(a and~ isomers) a-Terpinyl acetate /?-Terpinyl acetate

CH3 H3C
OCOCH3
\’

H~ OCOCHj Q ‘CH2
H3C

18 Thymol —

“c \ / $
Q
OH
—.
19 /7-Caryophyllene CH~

‘CH2

CH,
Q
CH~


20 a-Santalol CH,

h ,CH3
HIC— C—CH2– CH2CH=C
\
CH20H
LLJ

21 Eugenol CHZCH=CH2

:1
OCH,
o
OH
— _—— —
22 1-Octen-3-ol
OH
I
CH+CHJACHCH=CH2

m
23 2-Methylisoborneol CH, CH3
OH
CH3CCH3

24 Methional
CH3- S-CH2CH2CH0
IS 15285:2003
ISO 5496:1992

Annex B
(informative)

Specimen answer form

Test method: Identification of odours

Assessor’s name:

Date:

Do you perceive Do you recognize


Sample an odour?t) this odour?l) Name of the odour, description
Remarks
No. of the odour or association
Yes No Yes No

1) Put a cross in the appropriate column.

12
IS 15285:2003
ISO 5496:1992

Annex C
(informative)

Retro-nasal method of assessing odoursin gaseous phase byplacing smelling strips


into the buccal cavity

C.1 Principie Rapidly dip the bottom ends of the strips (C.3.1) (for
each of the assessors), one by one, in the flask or,
Assessment of a series of odoriferous substances preferably, using a dropper (C.3.4), place a drop of
placed on smelling strips. Insertion of the smelling the substance on the bottom end of each strip.
strip into the buccal cavity and assessment of the
The strip shall not be over-impregnated with sol-
odour by retro-nasal means,
ution; the migration front of the liquid shall be be-
tween 5 mm and 10 mm from the bottom end of the
C.2 Substances strip.

C.2.I Odoriferous substances, chosen for example Piace the prepared strip on the strip-holder or pick
it up with the tweezers (C.3.2), taking care that the
from table A.2,
strips do not come into contact with each other.
Leave the strips for a few seconds to allow any
C.3 Apparatus evaporation of the solvent to occur.

C,3.I Smeiiing strips: small strips of filter-paper, of C.5 Procedure


variable porosity depending on the manufacturer,
and of various shapes (rounded, bevel led etc. )e}. Hand the prepared strips to the assessors and in-
struct them to proceed as follows.
C.3.2 Strip hoiders, or tweezers, made of an
odourless material. The assessor places the strip in his/her mouth tak-
ing care not to touch any mucous membraneTl and
C.3.3 Tinted giass flasks, of suitable capacity for then, with lips closed, the assessor breathes
holding the odoriferous substances (one flask per normally, Depending on the product, the olfactory
substance). sensation occurs on the second (or sometimes sub-
sequent) exhalation.
C.3.4 Droppers (optional).
Before describing the olfactory sensation, the
assessor records the speed of appearance and dis-
C.4 Preparation of samples appearance of the olfactory sensation. The assessor
then replies to the questions on the answer form
Where necessary, prepare in accordance with the (see clause 7). (See the specimen answer form in
instructions given in A.2 suitable dilutions of the annex B.)
substances used to obtain the appropriate concen-
trations recommended in table Al. The assessor then goes on to assess the next sub-
stance,
Prepare one substance at a time and place in a
flask. C.6 Interpretation of results

Interpret the results in accordance with clause 8.

6) The names of suppliers can be obtained from manufacturers of aromatic products.


7) It is recommended that assessors be given prior training with a non-impregnated strip.
Bureau of Indian Standards

BIS is a statutory institution established under the Bureau of /rtchn Standards Act, 1986 to promote
harmonious development of the activities of standardization, marking and quality certification of
goods and attending to connected matters in the country.

Copyright

BIS has the copyright of all its publications. No part of these publications may be reproduced in any
form without the prior permission in writing of BIS. This does not preclude the free use, in the course
of implementing the standard, of necessary details, such as symbols and sizes, type or grade
designations. Enquiries relating to copyright be addressed to the Director (Publication), BIS.

Review of Indian Standards

Amendments are issued to standards as the need arises on the basis of comments. Standards are also
reviewed periodically; a standard along with amendments is reaffirmed when such review indicates that
no changes are needed; if the review indicates that changes are needed, it is taken up for revision.
Users of Indian Standards should ascertain that they are in possession of the latest amendments or
edition by referring to the latest issue of ‘BIS Catalogue’ and ‘Standards: Monthly Additions’.

This Indian Standard has been developed from Dot: No. FAD 58 (1 121).

Amendments Issued Since Publication

Amend No. Date of Issue Text Affected

BUREAU OF INDIAN STANDARDS


Headquarters:
Manak Bhavan, 9 Bahadur Shah Zafar Marg, New Delhi 110002 Telegrams: Manaksanstha
Telephones: 3230131, 3233375, 3239402 (Common to all offices)
Regional Offices: Telephone
Central : Manak Bhavan, 9 Bahadur Shah Zafar Marg 3237617,3233841
NEW DELHI 110002
Eastern : 1/1 4 C.I.T. Scheme Vll M, V.I.P. Road, Kankurgachi 3378499,3378561
KOLKATA 700054 { 3378626,3379120

Northern : SCO 335-336, Sector 34-A, CHANDIGARH 160022 603843


{ 602025
Southern : C.I.T. Campus, IV Cross Road, CHENNAI 600113 2541216,2541442
( 2542519,2541315
Western : Manakalaya, E9 MlDC, Marol, Andheri (East) 8329295, 8327858
MUMBAI 400093 { 8327891,8327892
Branches : AHMEDABAD. BANGALORE. BHOPAL. BHUBANESHWAR. COIMBATORE. FARIDABAD.
GHAZIABAD. GUWAHATI. HYDERABAD. JAIPUR. KANPUR. LUCKNOW. NAGPUR.
NALAGARH, PATNA. PUNE. RAJKOT. THIRUVANANTHAPURAM. VISAKHAPATNAM.

Printed at Simco Printing Press, Delhi

You might also like