This card requires a separate XFP transceiver for each port. The following
10-Gbps XFP transceivers are supported:
• 10GBase-SR—Short Reach
• 10GBase-LR—Long Reach
• 10GBase-ER—Extended Reach
• 10GBase-ZR—Extreme Reach
Stop!
Transceiver modules that have not been tested and qualified by Ericsson may
cause power and overheating problems on line cards. Install only transceivers
approved by Ericsson for use on the line card. For more information, see
Manage an Unsupported Transceiver.
• Booting
• OOS because of a non-fault
condition. Check the status
of other LEDs.
Off The card is not actively
providing service. It is either:
Transmitter
Optical output power –7.3 dBm (min) –8.2 dBm (min) –4.7 dBm (min) 0.0 dBm (min)
–1.0 dBm (max) 0.5 dBm (max) 4.0 dBm (max) 4.0 dBm (max)
Receiver
Wavelength range 840 to 860 nm 1270 to 1565 nm 1270 to 1565 nm 1270 to 1565 nm
Sensitivity –11.1 dBm (max) –12.6 dBm (max) –14.1 dBm (min) –22.1 dBm (min)
Overload level –1.0 dBm (max) 0.5 dBm (max) –1.0 dBm (max) –7.0 dBm (max)
• Out-of-service diagnostic (OSD) boot occurs by user request with the diag
out-of-service command. This boot sequence runs more extensive
diagnostic tests than a cold boot.
If you enter the show chassis command while the card is in diag mode,
the operational status is shown as oos-diag.
Warning!
Risk of card damage. When downgrading Ericsson IP Operating System to an
older release that does not recognize a particular line card or Smart Services
Card (for example, a node with 20-port 1/10GE line card which was introduced
in SSR 14B release downgraded to SSR 13B release), the new line card may
get damaged. To prevent this from happening, remove or unconfigure the
card prior to the system downgrade. Contact your support representative for
further assistance.
Stop!
The line card and the Ericsson IP Operating System must be running the
correct version of the boot ROM. The operating system on the card must be
Linux with kernel version 2.6 or later, with the capability to support ccNUMA
architecture. To avoid a serious equipment outage in the field, you must run the
operating system Release 14.1.1 or later on the card.
Note: When you move a line card or Smart Services Card from one chassis
to a newer chassis (for example, from an SSR 8020 to an SSR 8004
chassis), the card continues to operate with the older image. Images
prior to 14A CP01 do not support the SSR 8004 chassis and an image
mismatch may cause the card to reboot repeatedly. Contact your
support representative to recover from this condition.