You are on page 1of 20

FUJIFILM

Endoscopy System
Electronic Video Endoscopy and
Endoscopic Ultrasonography

FUJIFILM Asia Pacific Pte. Ltd.


10 New Industrial Road, FUJIFILM Building, Singapore 536201
PRODUCT GUIDE
http://www.fujifilm.com.sg Specifications are subject to change without notice.
Enhancing the quality of life of people worldwide

FUJIFILM is known as the world’s largest photographic and imaging company and is pioneering in diagnostic Index
imaging and information systems for health-care facilities. The current endoscopic equipment provides high-definition
video endoscopy and endoscopic ultrasound for gastroenterologists and pulmonologists. The actual range of 600 series and EPX-4450HD Technology 4 – 12
endoscopes and the EPX-4450HD processor technology come with FICE Dual Mode and DICOM on-board. 600 series endoscopes 13
580 series endoscopes 14 – 15
We will use leading-edge, proprietary technologies to provide top-quality products and services that contribute Double Balloon Endoscope 16 – 20
to the advancement of culture, science, technology and industry, as well as improved health and environmental 590 series endoscopes 21 – 23
protection in society. Our overarching aim is to help enhance the quality of life of people worldwide. 2500 system 24 – 25
530 series endoscopes 26 – 30
Innovative solutions New opportunities Therapeutic Accessories 31 – 32
As one of the leading companies in the development Whether it is with the most advanced optical technology, Endoscopic ultrasonography 33 – 36
of endoscope technology, FUJIFILM regularly state-of-the-art digital image processing or new Peripherals 37
sets new benchmarks in the industry, for example examination methods, FUJIFILM is always creating Processors 38 – 39
with devices for double balloon endoscopy and new opportunities in the world of endoscopy. In this
transnasal endoscopy. However, the focus at way, we are making a significant contribution to the
FUJIFILM is very much on holistic patient care. Our early detection of diseases and their successful
service portfolio therefore also includes competent treatment.
technical assistance, a comprehensive range of
hygiene products and individual consulting. Dedicated research, the continuous enhancement
of our technology, the highest quality demands and
close working relationships with international specialists
set the global standard in FUJIFILM endoscopy
and endosonography.
600 series and EPX-4450HD Technology

600 series CMOS endoscope & EPX-4450HD system: a solution for


new horizons in endoscopy realized by CMOS Technology

With advanced total solutions, FUJIFILM is ready to fulfill a broad range of diagnostic and therapeutic endoscopic
requirements.

600 series CMOS endoscopes feature leading-edge optical technologies to provide clear, bright endoscopic
images for easier and more accurate diagnosis. The ergonomic grip design ensures a smooth and comfortable
handling. The fully digital processor EPX-4450HD employs state-of-the-art digital signal processing. This system
is also optimized to employ the latest FICE imaging capability. FUJIFILM’s endoscopy system is a total solution to
support image input, processing and sharing, surely contributing to more efficient endoscopy from now on with
its excellent performance.

Gradual
CMOS Stiffness
Technology

EUS

Therapeutic
Ultra-slim Endoscopy
DICOM TNE
Endoscopy

4 600 series and EPX-4450HD Technology 600 series and EPX-4450HD Technology 5
Fi ts r ig ht. Moves ag i lel y. Light-weight grip for high operability The leading-edge 600 series CMOS endoscopes with full digital processor
EPX-4450HD realize advanced observation and diagnosis
The newly developed grip fits gently into your hand, allowing full use of this high-performance endoscope.
Materials, processing and choice of parts have all been reviewed to reduce the grip weight for greater
maneuverability. The design is improved also to allow easier
CMOS Technology
Mega
cleaning and disinfection. G-5 grip and 600 series endoscope CMOS Pixel
Technology 60P Video

in combination offer you added amenity in routine diagnosis.


Over megapixel CMOS image sensor producing high-definition image
By adopting over megapixel CMOS image sensor, 600 series endoscopes enable high-definition image to be produced.
Circumference
And the leading-edge CMOS Technology realizes less noise and brilliant image. To adopt CMOS image sensor can change the
- 10 mm analog signal to digital in the tip of scope. During transmission of signal, the digital signal is much less affected by the noise from
the outside. Those features make advanced observation and diagnosis possible.

Designed lighter & slimmer


20 % less in weight and 10 mm slimmer than that of our
conventional product. The angle operation knob
is remodeled to accommodate the fingers
more firmly with better fit.

Improved operability
New positioning of the functional
switches, air/water and suction
valve minimize finger travel and
improve efficiency.
Improved cleaning and disinfection EG-600WR EC-600WM/WI /WL

Water jet function Cleanliness and safety focused on full defense against
Main endoscopes for the lower gastrointestinal tract contamination. Easily soiled air/water valve is removable Megapixel 60P (60 frames/s progressive) video realizes smooth and clear video ability
have a water jet nozzle in addition to the forceps channel. and autoclavable. A smoother, flatter surface assures all CMOS Technology realizes 60P video even though over megapixel. With the 60 frame progressive scanning method, it is
The water jet nozzle effectively removes mucus on the areas receive optimal contact with cleaning and high- possible to produce not only smooth and clear video but also high-definition and less blur still images.
surface being examined. performance disinfecting solutions.
Progressive Interlaced

All lines are being read out at the same time First scan (red line only) , second scan (blue line only)

Light-weight connector Flexible portion 60P 60i


The connectors incorporated in the 600 and 500 series In upper and lower gastrointestinal endoscopy, the great 60 images / 1 sec 60 images / 1 sec
endoscopes are slim, light-weight, and easy to handle. flexibility of the endoscope allows easy insertability and the Each image is over one Megapixel Each image only contains half of the scan

Procedures are easy when the endoscope has to be comfort of the examinee.
removed/attached for
cleaning and disinfection
on every occasion of
endoscopy.
Overlay

Freeze
moving object

6 600 series and EPX-4450HD Technology 600 series and EPX-4450HD Technology 7
Close Focus with CMOS Technology FICE (Flexible spectral Imaging Color Enhancement)
Close
Focus

Tissue surface
Close Focus with CMOS Technology enhance image for diagnosis FICE – “Flexible spectral Imaging Color Enhancement“ – in the new
White light Conventional image
The newly designed high performance optical system enhances close focus observation capability up to 2 mm. The focus EPX-4450HD yields diagnostic results without any need for tissue
at the edges of an image has been improved, minimizing distortion in observation of a lumen. Through a combination with staining. The procedure digitally limits the wavelengths of the light and
the Megapixel CMOS image sensor, high performance optical system assists various observations ranging from close-up displays it in up to ten different color combinations. The endoscope
to distant views. switch allows physicians to switch between the conventional image
and the FICE image in a split second, ensuring an uninterrupted
Engine
examination with the eyes always concentrated on the monitor.

400nm 700nm

Reconstructed image
(FICE image)

FICE with CMOS Technology


EG-600WR EG-600WR EC-600WM / WI / WL

FICE combination with CMOS Technology provides advanced FICE image


Through high-definition and improved noise reduction, FICE images are sharper and clearer than ever.
It enables easier differentiation between lesion-affected and non-affected tissue.
Anti-blur function
Anti-blur function: extracting the best still image from multiple images
The anti-blur function offers sharpest and clearest images for review and documentation in any occasion.

* This diagram shows how the function works


FICE1 Esophagus FICE 1 Stomach
A sequence of images always Freezing the image during Automatic selection and display of the sharpest image
kept in the background the examination

Auto photometric control


Achieving always optimal illuminated images with
automatic control of the photometric mode
The automatic photometric mode optimally adjusts the lighting in
accordance with the positioning of the endoscope, providing you
with a well-balanced picture from close-up to distant focusing.
* Available with the 600 and 500 series endoscopes FICE 1 Colon FICE 8 Colon

8 600 series and EPX-4450HD Technology 600 series and EPX-4450HD Technology 9
E-Zoom (Electronic Zoom) provides better visibility Newly developed insertion portion for better insertion into the colon
E-Zoom image can be provided by pressing the scope button once. Normally, E-Zoom Gradual
Stiffness
enhance noise of image. However less noise 600 series FICE image allow to use E-Zoom
function. It is possible to observe the detail of surface pattern as well as vascular pattern. Gradual Stiffness
The flexibility of the insertion portion gradually increases toward the distal end. Gradual stiffness level is adjusted as
comfortable for insertion. It is possible to transmit the insertion power to the tip of scope more effectively.
Endoscopes with Gradual Stiffness
EC-600ZW/M, L (New)
EC-600WM/WI/WL (New)
EC-580RD/M,L (New)
EC-590ZW3/M, EC-590ZW3/L
EC-590WM4/WI4/WL4 Soft Softer
EC-530WM3/WI3/WL3

Gradual Stiffness Technology

White light Stomach FICE 0 + E-Zoom

Hard Harder

Dual Mode simultaneously display a FICE image


Conventional Type Gradual Stiffness
and white light image on the same monitor
By having a dual view of a FICE image and white light image on
the same monitor, you can collect more information for Improved torque and force transmission
examination and diagnosis. and operation ability
By adopting newly developed insertion portion both torque and force transmission have
been improved. Even when the tip of scope is located in the deep part of colon, the tip of
scope can react sensitively. It’s small diameter of 12.0 mm (for EC-600WM/WI/WL) aims
to produce better operability and reduce patient’s discomfort.

FICE 1 Stomach Anti-Slip


Improved grip performance with newly-designed surface shape
Ribbed surface prevents slipping and improves handling of the endoscope. Colonoscopy can be performed more easily and
Change the FICE preset pattern with the endoscope switch in real-time* comfortably even in long examinations.
Use the endoscope button to select up to three wavelength patterns from presets. You can switch quickly, moving to the next
FICE image with a single push of a button which allows selection of the best pattern for the respective diagnosis. Conventional Type Anti-Slip

White light FICE 0 FICE 1 FICE 8

Instant switching (switch patterns in rotation)


*Only when using the EPX-4450HD

10 600 series and EPX-4450HD Technology 600 series and EPX-4450HD Technology 11
600 series endoscopes

Video Gastroscope Multi Zoom function


EG-600WR CMOS
Mega
Pixel
Close
Focus
Water The new gastroscope EG-600ZW and the new
Technology 60P Video Jet
Normal Low Middle High Maximum
colonoscope EC-600ZW are both equipped with a Mode (x135*)
Light guide
Multi Zoom function. This function has four different
Field of view 140°
Continuous
Objective lens focus modes: "2 Step", "3 Step", "5 Step" and
Observation range 2 ~ 100 mm Forceps channel
Air/Water nozzle
Water jet
"Continuous". In the Step Zoom modes, the focus 2 Step
UP 210° / DOWN 90°
Bending capacity
RIGHT 100° / LEFT 100° can be switched between different magni cation
210˚ UP 100˚ LEFT
levels (such as between Normal and Low, or Low 3 S tep
Distal end diameter 9.2 mm
Flexible portion diameter 9.3 mm 90˚ DOWN 100˚ RIGHT and Middle) with a simple press of a button. The 5 S tep
Forceps channel diameter 2.8 mm users can choose the mode that suits them most
*When using a 19 inch LCD monitor
Working length 1,100 mm
Image area &
based on their preference and level of expertise.
Total length 1,400 mm Forceps entry position The newly designed optical system provides a wider observation range and makes it easier to focus on the target from close
Water jet Equipped distances. The focus has also been improved to provide smoother transitions between the different magni cation levels.

Video Gastroscope Mega


Pixel
Close
Focus
CMOS Water

EG-600ZW Technology 60P Video Jet

Light guide
Objective lens
Field of view Normal: 140° / Closest: 56°
Air/water nozzle Water Jet
1.5-100 mm
Forceps channel
Observation range Normal: 3-100 mm
Closest: 1.5-2.5 mm
210°Up 100°Left
UP 210° / DOWN 90°
Bending capacity
RIGHT 100° / LEFT 100° 90°Down 100°Right

Distal end diameter 9.9 mm


Flexible portion diameter 9.8 mm
Image area &
Forceps channel diameter 2.8 mm Forceps entry position
Working length 1,100 mm
Total length 1,400 mm
Video Colonoscope Water jet Equipped
EC-600WM / WI / WL CMOS
Mega
Pixel
Close
Focus Gradual
Stiffness Water
Technology 60P Video Jet

Field of view 140°


Observation range 2 ~ 100 mm
UP 180° / DOWN 180°
Bending capacity
RIGHT 160° / LEFT 160° Video Colonoscope Mega Close Gradual
Pixel Focus
CMOS Water Stiffness
Distal end diameter 12.0 mm EC-600ZW/M, L Technology 60P Video Jet

Flexible portion diameter 12.0 mm Light guide


Forceps channel diameter 3.8 mm
Working length 1,330/1,520/1,690 mm Field of view Normal: 140° / Closest: 56° Water Jet Objective lens
Image area & Forceps channel Air/water nozzle
Total length 1,630/1,820/1,990 mm Forceps entry position 1.5-100 mm
Water jet Equipped Observation range Normal: 3-100 mm
Closest: 1.5-2.5 mm
180°Up 160°Left
UP 180° / DOWN 180°
Bending capacity
RIGHT 160° / LEFT 160° 180°Down 160°Right

Distal end diameter 12.8 mm


Flexible portion diameter 12.8 mm
Image area &
Forceps channel diameter 3.8 mm Forceps entry position
Working length 1,330 / 1,690 mm
Total length 1,630 / 1,990 mm
Water jet Equipped

12 600 series endoscopes 600 series endoscopes 13


580 series endoscopes

580 New Super CCD series endoscopes Smart Bend (EC-580RD/M,L)


210°
The newly designed 580 New Super CCD realizes the high-definition even though small size image sensor.
Smart Bend

Smart Bend provides excellent maneuverability, observation and treatment by 210 º


up angulation, smaller bending radius and shorter rigid part

Smart Bend features allow precise manipulation, enabling


observation and treatment of areas usually difficult to
approach, like overlapping or folded parts. Thus, the great
Previous Super CCD 580 New Super CCD
bendability helps a wide range of procedures efficiently
including screening, diagnosis and treatment such as
EMR and ESD.
Forceps channel diameter of 2.4mm for transnasal scope (EG-580NW2)
By increasing the forceps channel diameter from 2.0mm to 2.4mm, the suction capacityimproved by approximately 1.4 times
compared with previous models.
When a biopsy forcep is inserted, the suction performance is increased by approximately 7 times, thus assisting faster
examinations.
UP
210° EC-580RD/M,L EC-530MP,LP

Video Gastroscope - Treatment Type


EG-580RD Light guide Water
Jet

Objective lens
Air/water
Field of view 140° nozzle
Water jet nozzle
Observation range 3~100 mm
Forceps channel
UP 210° / DOWN 90°
Bending capability
RIGHT 100° / LEFT 100° 210°UP 100°LEFT

Distal end diameter 9.8 mm


120°DOWN
N 100°RIGHT
Flexible portion diameter 9.8 mm
Forceps channel diameter 3.2 mm
Working length 1,100 mm
Image area &
Total length 1,400 mm Forceps entry position
Water jet Equipped

Video Gastroscope - Transnasal Type Video Colonoscope – Slim/TreatmenType 210°


Gradual
EG-580NW2 EC-580RD/M, EC-580RD/L Smart Bend
Stiffness Water
Jet

Light guide
Objective lens
Field of view 140° Field of view 140°
Observation range 3~100 mm Observation range 3~100 mm Air/water nozzle Water jet

UP 210° / DOWN 90° UP 210° / DOWN 160°


Bending capability Bending capability Forceps channel
RIGHT 100° / LEFT 100° RIGHT 160° / LEFT 160°
Distal end diameter 5.8 mm Distal end diameter 9.8 mm
Flexible portion diameter 5.9 mm Flexible portion diameter 10.5 mm
Forceps channel diameter 2.4 mm Forceps channel diameter 3.2 mm
Working length 1,100 mm Working length 1,330 / 1,690 mm
Total length 1,400 mm Image area & Total length 1,630 / 1,990 mm Image area &
forceps entry position forceps entry position
Water jet Equipped

14 580 series endoscopes 580 series endoscopes 15


Double Balloon Endoscope

New therapeutic Double Balloon Endoscope with 3.2 mm diameter 3. 2 m m f o r c e p s c h a n n e l


forceps channel – ideal for various procedures DBE
3.2mm

A large forceps channel of 3.2 mm in diameter for effi cient treatment


High-definition therapeutic Double Balloon Endoscope EN-580T

2.8mm 3.2mm
3.6 times

Suction volume
The 3.2 mm diameter forceps channel
providing greater suction performance
than that of conventional models.

EN-580T EN-450T5

With Φ2.4 device



According to FUJIFILM data

The 3.2 mm diameter forceps channel suits various procedures like hemostasis and balloon dilation.
As it enables blood or mucus to be aspirated while a therapeutic device is inserted, quicker hemostasis
is possible. The large forceps channel is also intended for easier insertion and removal of a balloon
catheter before and after dilation of structures.

16 Double Balloon Endoscope Double Balloon Endoscope 17


580 New Super CCD with Close Focus One-touch connector and relocated balloon air feed inlet
Close
Focus

Newly designed one-touch connector and relocated balloon air feed inlet
Superior image quality in close focus for more detailed diagnosis for better operability
The new high-definition Super CCD ensures vivid and high quality images, while the newly designed Close Focus The balloon air feed inlet has been relocated from the control portion to the connector portion, creating a better examination
optics enhances the possibility of obtaining more detailed images, thus allowing the compilation of a wide range of environment. Also, a one-touch type connector especially designed for the balloon air feed inlet on the endoscope is
data necessary for diagnosis. Used in combination with FICE, it provides better contrast for vascular and surface provided, making the preparation simpler.
patterns in close focus, emphasizing the structure of tissue aspects and vessels.

Enteroscope – Treatment Type Close


Focus
DBE

EN-580T / EN-530T
3.2mm

Viewing direction 0° (Forward)


Light guide
Field of view 140°
Observation range 2-100 mm Objective lens
Distal end diameter 9.4 mm Forceps channel
Flexible portion diameter 9.3 mm Air/water nozzle

UP 180° / DOWN 180° 180°UP 160°LEFT


Bending capability
RIGHT 160° / LEFT 160°
Working length 2,000 mm 180°DOWN 160°RIGHT
Total length 2,300 mm
Forceps channel diameter 3.2 mm
New Super CCD EN-580T Image area &
Forceps entry position
White light image of intestinal villi FICE image of intestinal villi Super CCD EN-530T

18 Double Balloon Endoscope Double Balloon Endoscope 19


590 series endoscopes

Overtube High-quality image endoscope with Super CCD


TS-13140 TS-13140

Overtube model TS-13140 TS-13101 The FUJIFILM Super CCD provides high-definition image quality and supports the
Outer diameter 13.2 mm 13.2 mm detection of smallest lesions.
Total length 1,450 mm 950 mm
Applicable EN-580T
EC-450BI5
endoscope EN-530T
BS-2
BS-2
Outer diameter 35 mm

ST-10

Balloon Setting Tools


ST-05B and ST-10

ST-05B

Balloon controller
PB-20
Power 35 mm
Maximum flow rate of pump 170 ml ± 50 ml /10 sec
Dimensions 350(W)x130(H)x420(D)mm
10kg (Main unit), 0.4kg
Weight
(Remote switch)

2 points (for endoscopes;


Balloon air outlets
for overtube)
Super CCD 590 series endoscopes

Colonoscope – Standard Type Video Gastroscope

E C - 4 50 B I 5 EG-590WR Light guide


Light guide
Objective lens

Objective lens
Viewing direction 0° (Forward) Air/water Viewing direction 0° (Forward)
nozzle Air/water
Field of view 140° Forceps channel Field of view 140° nozzle Forceps channel

Observation range 3-100 mm Observation range 6 - 100 mm


210°UP 100°LEFT
Distal end diameter 9.4 mm Distal end diameter 9.6 mm
180°UP 160°LEFT
Flexible portion diameter 9.3 mm Flexible portion diameter 9.3 mm
90°DOWN 100°RIGHT
Bending capability UP 180° / DOWN 180° 180°DOWN 160°RIGHT Bending capability UP 210° / DOWN 90°
RIGHT 160° / LEFT 160° RIGHT 100° / LEFT 100°
Working length 1,520 mm Working length 1,100 mm
Image area &
Total length 1,820 mm Image area & Total length 1,400 mm Forceps entry position
Forceps entry position
Forceps channel diameter 2.8 mm Forceps channel diameter 2.8 mm

20 Double Balloon Endoscope 590 series endoscopes 21


Video Gastroscope – Optical Magnifi cation Video Colonoscope
EG-590Z W EC-590W M4, EC-590WI4, EC-590W L4
OPTICAL Gradual
Water Stiffness
MAGNIFYING Jet
Light guide Light guide
WM4 WI4 WL4
Viewing direction 0° (Forward)
Objective lens
Viewing direction 0° (Forward) Objective lens
Field of view 140° Air/water nozzle
Air/water Forceps channel
Field of view WD: 140° / TL: 55° nozzle Observation range 3-100 mm Forceps channel
Water jet nozzle
Observation range WD: 6 - 100 mm / TL: 2 - 3mm Distal end diameter 12.8 mm
Distal end diameter 10.8 mm 210°UP 100°LEFT Flexible portion diameter 12.8 mm 180°UP 160°LEFT
Flexible portion diameter 9.8 mm UP 180° / DOWN 180°
90°DOWN 100°RIGHT Bending capability 180°DOWN 160°RIGHT
Bending capability UP 210° / DOWN 90° RIGHT 160° / LEFT 160°
RIGHT 100° / LEFT 100° Working length 1,330 mm 1,520 mm 1,690 mm
Working length 1,100 mm Total length 1,630 mm 1,820 mm 1,990 mm
Image area & Image area &
Total length 1,400 mm Forceps entry position Forceps channel diameter 3.8 mm Forceps entry position
Forceps channel diameter 2.8 mm Water jet Equipped

590 series endoscopes provide high-definition image Video Colonoscope – Optical Magnifi cation
EC-590Z W3/ M, EC-590Z W3/ L Gradual OPTICAL
Water Stiffness
Jet MAGNIFYING
Light guide
ZW3/M ZW3/L
Viewing direction 0° (Forward)
Objective lens
Field of view WD: 140° / TL: 55° Air/water nozzle
Observation range WD: 6-100 mm / TL: 2-3 mm Forceps channel
Water jet nozzle
Distal end diameter 12.8 mm
Flexible portion diameter 12.8 mm 180°UP 160°LEFT

UP 180° / DOWN 180°


Bending capability 180°DOWN 160°RIGHT
RIGHT 160° / LEFT 160°
Working length 1,330 mm 1,690 mm
Total length 1,630 mm 1,990 mm
Image area &
Forceps channel diameter 3.8 mm Forceps entry position
Water jet Equipped

Esophagus Esophagus (Zoom)

Optical Zoom structure FICE 0 Stomach (Zoom) Colon (Zoom) FICE8 Colon (Zoom)

22 590 series endoscopes 590 series endoscopes 23


2500 system

The new high-definition standard in endoscopy T he EPX-2500 v ideo proces sor


High defi nition in everyday work

The FUJIFILM high-definition system represents the standard in digital endoscopy – in terms of both The EPX-2500 combines convenient operation with high-definition images that have optimal illumination.

technology and cost-efficiency. It enables us to provide you with endoscopy equipment that is more The digital video output (DVI) of the EPX-2500 produces images in high definition without loss of quality.

affordable than ever before. At the heart of the system is the EPX-2500 video processor, which Furthermore, the processor is equipped with a range of functions.

delivers images in high definition without loss in quality.

Two ports for connecting FUJIFILM 200 series and 530 series endoscopes
Integrated xenon light source for bright, uniformly illuminated images
Quick and simple operation
Picture-in-picture function with freeze mode for live-display
Better imaging of blood vessels
2x zoom for instant enlargement

High-quality 530 series endoscopes


cover screening, diagnosis and treatment
530 series endoscopes feature high-quality endoscopes which serve various kinds of examination and
diagnosis. The entire upper and lower G.I. including ultra-slim endoscopes.

24 2500 system 2500 system 25


530 series endoscopes

Video Gastroscope – Transnasal Type Video Gastroscope – Slim Type


140° WIDE VIEW
EG-530N W EG-530FP
ULTRA-SLIM
TRANSNASAL SLIM 8.5 mm
5.9 mm
Light guide
Light guide

Objective lens
Viewing direction 0° (Forward) Objective lens Viewing direction 0° (Forward) Forceps channel
Air/water Air/water
Field of view 140° nozzle Forceps channel Field of view 140° nozzle
Observation range 4-100 mm Observation range 3-100 mm
Distal end diameter 5.9 mm 210°UP 100°LEFT Distal end diameter 8.5 mm 210°UP 100°LEFT

Flexible portion diameter 5.9 mm Flexible portion diameter 8.5 mm


90°DOWN 100°RIGHT 90°DOWN 100°RIGHT
Bending capability UP 210° / DOWN 90° Bending capability UP 210° / DOWN 90°
RIGHT 100° / LEFT 100° RIGHT 100° / LEFT 100°
Working length 1,100 mm Working length 1,100 mm
Image area & Image area &
Total length 1,400 mm Forceps entry position Total length 1,400 mm Forceps entry position
Forceps channel diameter 2.0 mm Forceps channel diameter 2.8 mm

Video Gastroscope – Transnasal Type Video Gastroscope – Treatment Type


EG-530NP EG-530CT
ULTRA-SLIM
TRANSNASAL Water BIG CHANNEL
4.9 mm Light guide Jet
Light guide Air/water
nozzle
Objective lens
Viewing direction 0° (Forward)
Objective lens
Water jet nozzle
Field of view 140° Forceps channel
Forceps channel
Viewing direction 0° (Forward) Air/water Observation range 3-100 mm Light guide
nozzle
Field of view 120° Distal end diameter 10.8 mm
Observation range 3-100 mm 210°UP Flexible portion diameter 10.8 mm 210°UP 100°LEFT

Distal end diameter 4.9 mm UP 210° / DOWN 90°


120°DOWN Bending capability
Flexible portion diameter 5.1 mm RIGHT 100° / LEFT 100° 90°DOWN 100°RIGHT

Bending capability UP 210° / DOWN 120° Working length 1,100 mm


Working length 1,100 mm Total length 1,400 mm
Image area & Image area &
Total length 1,460 mm Forceps entry position Forceps channel diameter 3.8 mm Forceps entry position
Forceps channel diameter 2.0 mm Water jet Equipped

Video Gastroscope Video Gastroscope – Treatment Type


EG-530WR Light guide
EG-530D Water jet nozzle
Water
Jet
DUAL CHANNEL

Light guide

Light guide
Viewing direction 0° (Forward) Objective lens
Objective lens
Viewing direction 0° (Forward) Field of view 140° Forceps channel
Forceps channel
Air/water
Field of view 140° nozzle Forceps channel Air/water nozzle
Observation range 3-100 mm
Observation range 4-100 mm Distal end diameter 11.5 mm
210°UP 100°LEFT
Distal end diameter 9.4 mm Flexible portion diameter 11.5 mm 210°UP 100°LEFT

Flexible portion diameter 9.3 mm UP 210° / DOWN 90°


90°DOWN 100°RIGHT Bending capability
UP 210° / DOWN 90° RIGHT 100° / LEFT 100° 90°DOWN 100°RIGHT
Bending capability
RIGHT 100° / LEFT 100° Working length 1,090 mm
Working length 1,100 mm Total length 1,405 mm
Image area & Image area &
Total length 1,400 mm Forceps entry position Forceps channel diameter 3.8 mm / 2.8 mm Forceps entry position
Forceps channel diameter 2.8 mm Water jet Equipped

26 530 series endoscopes 530 series endoscopes 27


Video Duodenoscope – Treatment Type Video Colonoscope
Air/water nozzle BIG CHANNEL
ED-530X T, ED-530X T8 (Internal)
Objective lens EC-530W M3, EC-530WI3, EC-530W L3
Light guide Gradual
Stiffness Water
Jet
Forceps elevator Light guide
Viewing direction 98° (8° rearward) WM3 WI3 WL3
Forceps channel
Field of view 100° Viewing direction 0° (Forward)
Objective lens
Observation range 4-60 mm Field of view 140° Air/water nozzle
Distal end diameter 13.1 mm 130°UP 90°LEFT Observation range 3-100 mm Forceps channel
Water jet nozzle
Flexible portion diameter 11.5 mm Distal end diameter 12.8 mm
UP 130° / DOWN 90° 90°DOWN 110°RIGHT Flexible portion diameter 12.8 mm 180°UP 160°LEFT
Bending capability
RIGHT 110° / LEFT 90° UP 180° / DOWN 180°
Bending capability 180°DOWN 160°RIGHT
Working length 1,250 mm RIGHT 160° / LEFT 160°
Image area &
Total length 1,550 mm Forceps entry position Working length 1,330 mm 1,520 mm 1,690 mm
Forceps channel diameter 4.2 mm Total length 1,630 mm 1,820 mm 1,990 mm
Image area &
Forceps channel diameter 3.8 mm Forceps entry position
Water jet Equipped

Improved operability Excellent image quality


Easy to catch the papilla FUJIFILM’s Super CCD, which has been exclusively developed for
The objective lens arrangement and bending per- the endoscope, is built-in, providing clear images.
Video Colonoscope – Slim Type
formance have been properly arranged to catch
EC-530LP Light guide SLIM 11.0 mm
the papilla easily from various endoscope positions.

Objective lens
LP Air/water nozzle
Viewing direction 0° (Forward) Forceps
channel
Field of view 140°
Observation range 3-100 mm 180°UP 160°LEFT
Distal end diameter 11.0 mm
Flexible portion diameter 11.1 mm 180°DOWN 160°RIGHT

UP 180° / DOWN 180°


Bending capability
RIGHT 160° / LEFT 160°

Improved cleaning and disinfection Working length 1,690 mm Image area &
Forceps entry
Total length 1,990 mm position
Removable distal end cap*
Forceps channel diameter 3.2 mm EC-530MP EC-530LP
The ED-530XT8 is equipped with a disposable distal end cap.
Improved insertion capability of ERCP lt enables brushing all channels and helps to improve the
accessories into the papilla hygienic environment.
*ED-530XT8 only
Newly designed forceps elevator
has been applied to enhance
accessory control more precise- Video Colonoscope – Treatment Type
ly and securely, facilitating easier EC-530DL
Water DUAL CHANNEL
ERCP treatment. Light guide Jet

DL Air/water
nozzle
Viewing direction 0° (Forward) Objective lens
Forceps
Field of view 140° channel
Observation range 3-100 mm Water jet nozzle Forceps channel
Easy operability of the insertion portion Covered tilt-up mechanism Distal end diameter 12.8 mm
The stiffness of the insertion portion has been impro- A covered tilt-up mechanism of the Flexible portion diameter 12.8 mm 180°UP 160°LEFT

ved for easier stomach stretching forceps elevator maintains the Bending capability
UP 180° / DOWN 180°
RIGHT 160° / LEFT 160° 180°DOWN 160°RIGHT
and insertion capability. elevator wire clean without any
Working length 1,690 mm
additional cleaning procedure. Total length 2,005 mm
Image area &
Forceps channel diameter 3.8 mm / 2.8 mm Forceps entry position
Water jet Equipped

28 530 series endoscopes 530 series endoscopes 29


Therapeutic Accessories

Video Colonoscope F l u s h K n i fe BT / F l u s h K n i fe
EC-530FI, EC-530FL
Aimed at achieving enhanced usability ideal for all physicians from
Light guide Water
Jet
ESD trainees to skilled practitioners.
FI FL
Objective lens
Viewing direction 0° (Forward)
Field of view 140° Air/water nozzle
Forceps channel
Observation range 3-100 mm
Water jet nozzle
Distal end diameter 12.8 mm Water jet system maintains the sharpness of the knife
Flexible portion diameter 12.8 mm 180°UP 160°LEFT The water jet system keeps the tip of the knife clean by washing off debris
Bending capability
UP 180° / DOWN 180° and lesion tissue adhering to the tip, thereby maintaining the sharpness of
RIGHT 160° / LEFT 160° 180°DOWN 160°RIGHT
the knife throughout the treatment.
Working length 1,520 mm 1,690 mm
Total length 1,820 mm 1,990 mm
Image area &
Forceps channel diameter 3.8 mm Forceps entry position
Water jet Equipped

One knife covers from marking to arrest of bleeding, achieving high versatility
One knife carries out procedures including marking, incision, dissection and arrest of bleeding. The high versatility
improves operation and cost efficiencies.
Video Sigmoidoscope
ES -530WE
Water
Light guide Jet

Viewing direction 0° (Forward)


Objective lens
Air/water nozzle
Field of view 140°
Forceps
Water jet nozzle
Observation range 3-100 mm channel

Distal end diameter 12.8mm


Flexible portion diameter 12.8mm 180°UP 160°LEFT

UP 180° / DOWN 180° Marking Mucosal incision Submucosal dissection Arrest of bleeding
Bending capability
RIGHT 160° / LEFT 160° 180°DOWN 160°RIGHT

Working length 790mm


Total length 1,090mm
Image area &
Forceps channel diameter 3.8mm Forceps entry position
The tip is designed to enhance safety and treatment capability
Water jet Equipped
FlushKnife BT has a ball tip, which produces good traction, enabling the target tissue to be dissected smoothly.
The ball tip touches a wider part of the tissue and arrests bleeding more efficiently.

Safer and more efficient treatment is achieved by using the protruding knife length best suited for each treatment area.
Close
Focus
DBE
3.2mm

Enteroscope – Treatment Type FlushKnife BT FlushKnife


Light guide
EN-530T
Viewing direction 0° (Forward) Objective lens
Field of view 140° Forceps channel
Air/water nozzle
Observation range 2-100 mm
Distal end diameter 9.4 mm 180°UP 160°LEFT

Flexible portion diameter 9.3 mm


180°DOWN 160°RIGHT
UP 180° / DOWN 180°
Bending capability
RIGHT 160° / LEFT 160°
3 mm 2.5 mm 2 mm 1.5 mm 3 mm 2.5 mm 2 mm 1.5 mm 1 mm
Working length 2,000 mm
Image area &
Total length 2,300 mm Forceps entry position
Forceps channel diameter 3.2 mm

30 530 series endoscopes Therapeutic Accessories 31


Endoscopic ultrasonography

Single use Alligator Scissor Forceps EUS Tower – a l l-i n-one stack con cept
ClutchCutter
SU-8000
Rotatable alligator scissor forceps supports to perform a more
Years of research and development to reduce patient discomfort and
efficient and safer ESD. Uninsulated
improve operator efficiency during endoscope examinations led to the
Serrated jaws development of Sonart, the integration of ultrasonographic diagnosis and
Securely grip the mucous membrane. endoscopy systems.

Rotating jaws Insulated


For a more accurate diagnosis, advanced image processing technology
Approach the lesion at a more precise angle. integrates improved endoscope maneuverability and insertion capability.
The compact, one-cart system supports various applications.
Insulated outer edge
Minimize the risk of damaging local tissue.

One knife covers from marking to arrest of bleeding, achieving high versatility
Grasp the mucous membrane using the serrated jaws, lift and make an incision. Grasp and lift the submucosa,
look to confirm, and dissect. Coagulate any bleeding spots using the high-frequency jaws.

Incision Dissection Coagulation

Product name Single use Diathermic Slitter DP2618DT DP2618DT-35- DP2618DT-50-


Identifier -35- -50-
Jaw length 3.5 mm 5.0 mm A-cord connector
Working length 1800 mm
Insertion portion Jaws
Maximum diameter of insertion portion 2.7 mm
Forceps channel diameter of compatible
2.8 mm or more Handle Slider
endoscope

Jaws
Short-type ST hoods
Prevents the surgical field of view being blocked by mucosa and Features of short-type ST hoods
keeps it clear during the endoscopic treatment. Helps to perform Shorter distance from the endoscope tip and wider inner Flexible image display
safer and more efficient ESD and POEM. diameter of the distal end than current hoods, enhancing and switching
visibility. Two drain equipped. Easier insertion of acces- Keyboard operation facilitates
sories with the guide ditch eliminated. smooth examinations and allows Ultrasound image
Model name Outer Diameter Distance from Inner Diameter Drain Compatible Scope
the endoscope tip of distal end switching among an ultrasound

DH-28GR 11.8 mm 7.0 mm 8.0 mm 2


EG-600WR, EG-590WR, image, an endoscopic image,
EG-530WR, EC-450BI5
and a picture-in-picture image
EG-580RD, EC-580RD/M, L, with patient‘s history images.
DH-29CR 13.0 mm 7.0 mm 8.0 mm 2 EG-590ZW, EG-530CT,
EC-530LP
EC-600WL/WI/WM,
EC-590WL4/WI4/WM4,
DH-30CR 14.8 mm 7.0 mm 8.0 mm 2 Picture-in-picture image Patient’s history image
EC-590ZW3/L, M,
EC-530WL/WI/WM

Endoscopic image

32 Therapeutic Accessories Endoscopic ultrasonography 33


ZONE Sonography™ technology ensures Conventional Method ZONE Method Ultrasonic endoscopes
high-quality images
ZONE Sonography™ technology defines conventional wisdom in EG-530UR2, EG-530UT2
ultrasonography. The technology delivers wide ultrasound beams and EG-530UR2 and EG-530UT2 endoscopes combine FUJIFILM’s high-quality endoscope features with the most advanced
quickly acquires large amounts of echo data in sizeable zones. Split- ultrasound technology, to create an unsurpassed diagnostic and treatment system.
second data acquisition allows highly advanced image processing.

Excellent insertion capability


Newly designed structure of flexible portion improves
insertion capabilty. The tip with a small bending radius
allows better observation.

Consideration of the safety of fi ne


needle aspiration
Dotted yellow guidelines are visualized on the monitor
Sound Speed Correction technology improves image resolution to ensure the safety of paracentesis.
Advanced image processing technology estimates the optimal speed of ultrasound travelling through the body
(sound speed) and constructs images.
1450 m/s ATS Phantom

What is Sound Speed Correction?


The resolution in the lateral dimension High-quality endoscopic image
deteriorates due to a difference in Equipped with the Super CCD, this ultrasound endoscope offers bright, vivid, high-definition image.
sound speed. By correcting this and
carrying out optimization, the resolution
in the lateral dimension is improved.

Imaged at 1540 m/s Imaged at 1450 m/s


before Sound Speed Correction after Sound Speed Correction

Display quality images in different modes


Technologies developed in the field of ultrasonographic diagnosis improve the quality of ultrasound images.
Images created from advanced image processing enable the use of appropriate modes for your setting.
EG-530UR 2 EG-530UT2

C mode
The Color Doppler function obtains hemodynamic In pursuit of balloon operability
information in disease areas and helps you locate the An air/water and suction button inflates water to the balloon and deflates water from the balloon.
observation site and vascular structures.
SU-8000 Scanning modes; C mode, Power Doppler,
Pulse wave, B mode, M mode

Frequency switching CFM mode B mode

A wide range of frequencies (5, 7.5, 10, and 12 MHz)


helps to delineate clear C mode images of the regions.

34 Endoscopic ultrasonography Endoscopic ultrasonography 35


Peripherals

Radial Scan Ultrasound Video Endoscope Endoscopic CO2 Regulator


E G - 53 0 U R 2 GW-100

Viewing direction 0° (Forward)


Directly connectable to medical CO2 pipeline in the hospital
Field of view 140° The endoscopic CO2 regulator GW-100 is a versatile system,
Observation range 3-100 mm which can be connected to medical CO2 pipeline or CO2 gas cylinder.
Distal end diameter 11.4 mm
Flexible portion diameter 11.5 mm Easy-to-use CO2 flow rate switching function
Bending capability UP 180° / DOWN 90° The CO2 flow rate can be selected by one push of the button on the front panel.
RIGHT 100° / LEFT 100°
Air/water
Working length 1,250 mm Light guide nozzle Compact and lightweight
Total length 1,550 mm
Forceps channel The system is compact and lightweight, saving space on a cart.
Forceps channel diameter 2.2 mm
Objective lens
Dimensions 145x170x390mm (WxHxD)
Scanning mode Color Doppler, Power Doppler, 180°UP 100°LEFT Weight 6kg
PW Doppler, B mode, M mode
Power Requirements 100-240VAC±10%, 50/60Hz, 0.3A
Scanning method Electronic radial scan 90°DOWN 100°RIGHT Applicable Gas CO2 gas for medical use
Scanning angle 360° (Connectable to CO2cylinder or medical gas pipeline)
Frequency 5 Mhz / 7.5 Mhz / 10 Mhz / 12 Mhz Gas Supply Pressure 65kPa (max.)
Contact method Balloon method, degassed water Image area &
congestion method, contacting Forceps entry position
method Water pump
JW-2
Specially designed for advanced endoscopic examination
Proprietary piping technology enables water flow to be quickly stopped. One-liter water bottle enables prolonged water
use and minimizes the need for constant refilling.

Convex Scan Ultrasonic Video Endoscope


EG-530UT2

Viewing direction Forward oblique 40°


Field of view 140°
Observation range 3-100 mm
Distal end diameter 13.9 mm
Flexible portion diameter 12.1 mm
Bending capability UP 160° / DOWN 160°
RIGHT 120° / LEFT 120°
Ultrasonic oscillator EPX-4450H D i nteg rates i nto the hos pi ta l net wor k
Working length 1,250 mm Balloon slo
t
Balloon water port
Total length 1,550 mm environment with DICOM interfaces
Light guide
Forceps channel diameter 3.8 mm
A ir/water nozzl
e DICOM
Forceps elevator
Objective lens
Color Doppler, Power Doppler,
Scanning mode
PW Doppler, B mode, M mode, THI
160°UP 120°LEFT
Scanning method Electronic convex scan
110° (Combination with SU-7000) 160°DOWN 120°RIGHT
Scanning angle
124° (Combination with SU-8000)
Frequency 5 Mhz / 7.5 Mhz / 10 Mhz / 12 Mhz
Balloon method, degassed water Image area &
Contact method congestion method, contacting Forceps entry position
method

36 Endoscopic ultrasonography Peripherals 37


Processors

Video Processor Video Processor


EPX-4450H D EPX-2500 Digital output DVI (Digital Visual Interface): 1024 x 768 p
RGB (2): SDTV (NTSC / PAL)
Analog output Y/C (2): SDTV (NTSC / PAL)
Composite: SDTV (NTSC / PAL)
Color adjustment Black, Red, Green, Blue, R-Hue, Chroma; 9 settings
Detail Hi, LO; 9 settings
Contrast (gamma) 9 settings
BLD Hi, Mid, Lo, Off
Picture in picture On, Off; Size: 1/4, 1/3
Auto gain control Off, +3 db, +6 db
Iris Average / Peak
Zoom Electric zoom: x1.0 – x2.0; 0.05 steps
Main lamp: 11.7 V 150 W Xenon lamp
Lamp rated value
Emergency lamp: 12 V 75 W Halogen lamp
Brightness control 9 settings
Lamp cooling method Forced air cooling
Air supply pump Hi, Low, Off
Power 120 V 60 Hz 2.7 A / 230 V 50 Hz 1.4 A
Dimensions (W x D x H) 375 x 495 x 190 mm (including projections)
Weight 17.0 kg

Ultrasonic Processor
S U -80 0 0 AC120 V AC230 V
Power supply 60 Hz 50 Hz
2.2 A 1.4 A
Current consumption (rated) 1.8 A 1.2 A
EG-530U series scope
Applicable scopes
EB-530U series scope
Video terminal (1 channel)
S video terminal (1 channel)
RGB PC terminal (1 channel)
Video output terminal
VP-4450 HD Processor XL-4450 Light source RGB PC/TV terminal (1 channel)
DVI image input terminal (1 channel)
HD-SDI: HDTV 1080i (2ch) Main Lamp: 300 W Xenon lamp LMP-002
Lamp rated value HD-SDI terminal (2 channels)
Digital output DVI (Digital Visual Interface): 1280 x 1024 p Emergency Lamp: 75 W Halogen lamp
Ethernet: 100 / 10 Base Audio output terminal RCA terminal (1 channel)
Light control Automatic light control
RGB: 1280 x 1024 p DVI image input terminal (1 channel)
Analog output Lamp cooling method Forced air cooling
SDTV (120 V / NTSC, 230 V / PAL): RGB Y / C, Composite Video input terminal S video terminal (PROCESSOR) (1 channel)
Air supply pump High, Mid, Lo, Off
Color adjustment Brightness, Red, Green, Blue, R-Hue, Chroma; 9 steps S video terminal (SP702) (1 channel)
Light save On, Off
Detail Hi, LO; 9 steps
Transmitted illumination On, Off
Contrast (gamma) 3 steps
Power rating 120 V 60 Hz 3.3 A 230 V 50 Hz 1.7 A
Hyper-Sharpness Hi, Mid, Lo, Off Remote terminal (2 channels)
Dimensions (W x H x D) 390 x 155 x 450 mm
Color emphasis Hi, Mid, Lo, Off Foot Switch terminal (1 channel)
Weight 15 kg
Flexible spectral imaging Control terminal Keyboard terminal (1 channel)
FICE
Color Enhancement 10 presets
RS232C terminal (PROCESSOR) (1 channel)
Iris Average / Peak / Auto
RS232C terminal (SP702) (1 channel)
Image storage CF Card
Network terminal (1 channel) Ethernet (100 BaseTX)
Power rating 120 V 60 Hz 0.8 A 230 V 50 Hz 0.5 A
Storage CF memory card, networked shared folder (FTP, DICOM)
Dimensions (W x H x D) 390 x 105 x 460 mm Image storage
File format TIFF, JPEG
Weight 9.5 kg
External dimensions (W x H x D) 375 x 215 x 445 mm (including protruding parts)
DICOM MWL, Store
Weight 14 kg

38 Processors Processors 39

You might also like