You are on page 1of 9

Timing of porphyry (Cu-Mo) and base metal (Zn-Pb-Ag-Cu)

mineralisation in a magmatic-hydrothermal system – Morococha


district, Peru

Appendix 1

Corresponding author:

Honza Catchpole1,#
#
Corresponding author:
Current address: Vale Exploration Canada Inc., 2060 Flavelle Boulevard, Mississauga, Ontario,
Canada L5K 1Z9
email: catchpole@gmx.de
phone: +1 416 357 2231

Authors:

Kalin Kouzmanov1, Aldo Bendezú1 , Lluís Fontboté1, Maria Ovtcharova1, Richard

Spikings1, Holly Stein2,3 , Lluís Fontboté1


1
Department of Earth and Environmental Sciences, University of Geneva, Rue des Maraîchers
13, 1205 Geneva, Switzerland
Kalin.Kouzmanov@unige.ch
Aldobendezujuarez@yahoo.com
Maria.Ovtcharova@unige.ch
Richard.Spikings@unige.ch
Lluis.Fontbote@unige.ch
2
AIRIE Program, Department of Geosciences, Colorado State University, Fort Collins, CO
80523-1482, USA
3
Geological Survey of Norway, 7491 Trondheim
Holly.Stein@colostate.edu

Analytical procedures

Sample preparation
Phlogopite and muscovite samples were picked from vugs within the quartz-rich

veins, and hand picked in pure ethanol under a 50x binocular magnification to obtain an

inclusion free and pure grain sample. For all other minerals, including monazite, titanite,

adularia, and muscovite samples, a bulk vein / manto / rock crushing and separation protocol

was used, after diamond saw separation of the host rock.

Monazite and titanite separation: the crushed and sieved monazite-bearing fraction

was separated from the sulphide dominated >3.3 g/cm3 fraction with the heavy liquid

methylene-iodide (MEI). A concentrate of the paramagnetic monazite and residual pyrite with

alien sulphide inclusions was consequently separated using a Frantz Isodynamic Magnetic

Separator (University of Geneva) with parameter settings for monazite as outlined in

Rosenblum and Brownfield (1996). Monazites (80 – 100 µm) were handpicked from a pyrite

dominated separate under a 50x binocular magnification and separated from attached fine

grained and partly intergrown muscovite in an ultrasonic bath. The same procedure was

applied for titanite including parameter settings for magnetic separation of titanite as outlined

in Rosenblum and Brownfield (1996).

Molybdenite and pyrite separation: a small hand-held drill was used to extract

molybdenite as a powder from the quartz vein sample; although the effort was made, it was

impossible to avoid small quantities of finely-intergrown pyrite when creating the

molybdenite separate. To try dating of polymetallic base-metal mineralization, two pyrite

samples were acquired – one from a massive pyrite body at Sulfurosa and one from the

polymetallic San Andrès vein (Manuelita). For the San Andrès, a vial with pyrite mineral

separate was provided to the AIRIE Program. For the Sulfurosa, a sawed rectangle, ca. 2 cm

on a side, of massive granular pyrite was provided and a separate was drilled from a single

region of the cube for the Re-Os analysis.

Adularia separation: a crushed and sieved quartz-adularia-bearing non-magnetic

concentrate was obtained after magnetic separation. A heavy liquid separation MEI was used
to separate the >3.3 g/cm3 fraction, and consequently repeated steps of diluted sodium

polytungstate (SPT) at 2.6 g/cm3 using a centrifuge to achieve a clean separation of adularia

from quartz. Small sulphide inclusions impeded a pure separate in some cases, so all samples

were handpicked in pure ethanol under a 50x binocular magnification to obtain an inclusion

free and pure grain separate. The samples were finally cleaned for several minutes in

deionised water in an ultrasonic bath.

Final separates were tested for purity by powder X-ray diffraction (Philips X’Pert

APD, University of Geneva) of a crushed aliquot of each grain separate. Additional aliquots

were used for thin section grain mounts of ~20 – 40 grains of each sample and checked for

alteration textures and compositional inhomogeneities using scanning electron microscope

backscatter electron imaging (SEM-BSE; CamScan4, University of Lausanne).

Representative grain compositions were subsequently quantified by electron microprobe

analysis (Table 2).

U-Pb analytical methods

Sample clean laboratory preparation, mass-spectrometry and blank

Before dissolution fractions of 20-30 monazites and titanites of each sample were

placed into 3ml screw-top Savillex vials and were fluxed for about 1h in 3N HNO 3 on a hot

plate at ca. 80C. The acid solution was removed and the fractions were rinsed several times

in ultra-pure water and acetone in an ultrasonic bath. Single to multi-grain fractions of

monazites and titanites were selected, weighed and loaded for dissolution into pre-cleaned

3ml screw-top Savillex vials and miniaturised Teflon vessels, respectively. After adding a
205
mixed Pb-233U-235U spike (EARTHTIME, spike calibration described by Condon et al.

2010) and 120 l 6N HCL the Savillex vials with monazites were arranged into a Teflon
ParrTM vessel with 2 ml 6N HCl, and placed in an oven at 206C for 24 hours. The same

Pb-233U-235U spike was used for the titanites which were dissolved in 63 l concentrated HF
205

with a trace of 7N HNO3 at 206C for 2 days. After evaporation and overnight redissolution in

36 l 6N HCl at 206C the titanite samples were brought up in 36 l 1N HBr. For monazite

Pb and U were separated by anion exchange chromatography (Krogh 1973) in 40 l micro-

columns, using minimal amounts of ultra-pure HCl, and finally dried down with 3 l of

0.05M H3PO4. Titanite Pb and U separation was performed in two steps HBr chemistry

modified after Krogh, (1973). Uranium and Pb were collected in two different beakers and

dried with a drop of 0.05 M H3PO4.

The isotopic analyses were performed in University of Geneva on TRITON mass

spectrometer equipped with a linear MasCom electron multiplier. The SEM dead-time

(23.5ns) was determined and monitored periodically by measurements of NBS 982 for up to

1.3 Mcps. The linearity of the MasCom multiplier was calibrated using U500, Sr SRM987,

and Pb SRM982 and SRM983 solutions. The mass fractionation of Pb was controlled by

repeated SRM981 measurements (0.13 ± 0.02 %/amu 1-sigma). Uranium mass fractionation
233
is calculated in real-time using a U-235U double spike. Both U and Pb were loaded together

(for monazites) or separate (for titanites) with 1 μl of silica gel–phosphoric acid mixture

(Gerstenberger and Haase 1997) on outgassed single Re-filaments. Lead isotopes were

measured on the electron multiplier, while U (as UO 2) isotopic measurements were made in

static Faraday mode or, in case of very low-U samples, on the electron multiplier. Total

procedural lab blank was determined to be 1.8 ± 0.5 pg common Pb for monazite and 5 ± 1 pg

for titanite, which was used in the reduction of the data and corrected with the following
206
isotopic composition: Pb/204Pb: 18.30 ± 0.71%; 207
Pb/204Pb: 15.47 ± 1.03%; 208
Pb/204Pb:

37.60 ± 0.78% (all 1 sigma). Uranium blanks are <0.1 pg and do not influence the degree of

discordance at the age range of the studied samples. Therefore, a value of 0.05 pg +/- 50%

was used in all data reduction.


Data reduction, age reporting, and errors

Age calculations are based on the decay constants of Jaffey et al. (1971). The initial

statistics was done using the TRIPOLI program (Bowring et al. 2011), followed by data

reduction and age calculation using the YourLab xls program (Schmitz and Schoene 2007),

EARTHTIME project - http://www.earth-time.org/u-pb.html -, and applying the algorithm of

Ludwig (1980). Generation of concordia plots and averages are base on Isoplot/Ex v.3

(Ludwig 2005). All uncertainties are reported at 2 sigma level. All data are reported in Table 4

with internal errors only (including counting statistics, uncertainties in correcting for mass

discrimination, and the uncertainty in the common Pb composition). Weighted mean age and

the mean square of the weighted deviates (MSWD) are calculated according to York (1966;

1967), and reported at 95% confidence level. Concordia diagrams for all samples are shown

in Figure 9. The accuracy of the data was assessed by repeated analysis of the international

R33 standard zircon (Black et al. 2004), which was pre-treated by annealing–leaching, and
206
measured at an average Pb/238U age of 419.08 ± 0.19 Ma (N = 27; MSWD = 0.70). In

addition, a synthetic NIGL solution (Condon et al., in prep) was measured and yielded an

external reproducibility better than 0.1% in 206Pb/238U date.

Re-Os analytical methods

The use of molybdenite as a single-mineral chronometer is based on its extraordinary


187
Re/188Os ratios (Stein et al. 2001; Stein et al. 2003). In some cases, other sulphides (e.g.

pyrite) may have molybdenite-like Os isotopic compositions, but Re and Os levels are one or

more orders of magnitude lower than molybdenite (Stein et al. 2000). For this study, Re-Os

analyses were performed on two pyrite samples (530 mg) and one molybdenite sample (29
mg). The Re-Os data for the molybdenite were acquired using a Carius tube dissolution and a

mixed Re-double Os spike. The double Os spike is especially useful for working with young

and/or low Re molybdenites (Markey et al. 2003) or sulphides with molybdenite-like isotopic

compositions (Stein et al. 2000). The double spike allows determination and correction for

common Os as well as a mass fractionation correction for measured Os isotope ratios. Mass

fractionation for Re was overcome with analysis by total evaporation. Similarly, the Re-Os

data for the two analysed pyrites were acquired via Carius tube dissolution and sample-spike
185 190
equilibration, but using single Re and Os spikes. Further analytical details are found in

Markey et al. (2003). The Henderson Reference Material (RM8599), available through NIST,

is run routinely (Markey et al. 2007). Isotopic ratios were measured by negative thermal ion

mass spectrometry (NTIMS) on a Triton machine housed within the AIRIE Program at

Colorado State University. Blank values associated with the molybdenite analysis are Re =

3.35  0.06 pg, total Os = 2.00  0.02 pg, and Os/188Os = 0.230  0.001. Blank values
187

associated with the pyrite analyses are Re = 15.64  0.39 pg, total Os = 0.721  0.004 pg, and

Os/188Os = 0.182  0.002.


187

Infrared (CO2) laser 40Ar/ 39Ar analysis

Samples for 40Ar/ 39Ar analysis were loaded into Cu foil packages, mounted inside a

silica glass tube. Fish Canyon Tuff sanidine was added as a flux monitor assuming a standard

age of 28.02 ± 0.28 Ma (Renne et al. 1998). The tube was irradiated for 3 hours in the

cadmium-lined in-core irradiation tube (CLICIT) facility of the TRIGA reactor at the Oregon

State University Radiation Center, USA. The reactor irradiation correction values (J-values)

for each sample were calculated by interpolation of sample position in the silica glass tube.

Samples were analysed via incremental heating using a MIR10 IR 30W CO 2 laser and

a stainless steel extraction line coupled with a multi-collector Argus mass spectrometer (GV
Instruments), housed at the University of Geneva, and equipped with four high-gain (10 12 Ω

resistivity) Faraday cups for the measurement of 36Ar, 37Ar, 38Ar, and 39Ar, and a single 1011 Ω-

resistivity Faraday cup for 40Ar measurements. The samples were placed in small pits in a Cu

planchette and step-heated by laser rastering the pit area to ensure even-heating of the grains.

Usual degassing consisted of 9 - 15 temperature steps. Blanks for all argon isotopes were

measured at the beginning of a sample measurement and after every second step incremental

heating experiment and comprise the following ranges: 36Ar: 0.7–5.2 x 10-17 mol; 37Ar: 0.25–

1.1 x 10-16 mol; 38Ar: 0.7–7.4 x 10-17 mol; 39Ar: 0.17–2.0 x 10-16 mol; 40Ar: 0.54–1.4 x 10-14

mol. The released gas fraction was purified for six minutes using two hot getters (0.45A and

1.45A). Purified gas was then allowed to diffuse for 50 seconds into the static-vacuum multi-

collector Argus mass spectrometer. The high stability of Faraday baseline measurements

rendered it unnecessary to record baselines for each analysis. Isotopic mass/charge ratios were

collected using 12 cycles, which were then exponentially regressed to determine the

abundance of individual argon isotopes prior to fractionation in the source unit. Age plateaus

were determined using the criteria of Dalrymple and Lanphere (1971), which specify the

presence of at least three contiguous incremental heating steps with concordant ages that

constitute >50% of the total 39Ar released during the step-heating experiment. All ages were

calculated using decay constants and isotopic compositions of Steiger and Jäger (1977).

Inverse isochron diagrams (McDougall and Harrison 1999) allow to test the assumption made

for the plateau ages where any trapped non-radiogenic argon has an atmospheric composition

(40Ar/36Ar = 295.5). Raw data was reduced and the ages calculated using the ArArCALC

Excel macro application (Koppers 2002). The mass discrimination factor was calculated from

analysed clean air-standards in double-air pipette mode (mass discrimination factor: 0.989 ±

0.001 per atomic mass unit), including correction for peak heights and background, the

radioactive decay of 37Ar and 39Ar, as well as for nucleogenic interference from Ca-, K-, and
Cl-derived isotopes. Propagated systematic errors comprise decay constant, mass

discrimination, and J value uncertainties. All errors are reported at 2σ level.

References:

Black LP, Kamo SL, Allen CM, Davis DW, Aleinikoff JN, Valley JW, Mundil R, Campbell
IH, Korsch RJ, Williams IS, Foudoulis C (2004) Improved 206Pb/238U microprobe
geochronology by the monitoring of a trace-element-related matrix effect; SHRIMP,
ID–TIMS, ELA–ICP–MS and oxygen isotope documentation for a series of zircon
standards. Chem Geol 205:115-140
Bowring JF, McLean NM, Bowring SA (2011) Engineering cyber infrastructure for U-Pb
geochronology: Tripoli and U-Pb_Redux. Geochemistry, Geophysics, and Geosystems
12:19 doi:10.1029/2010GC003479
Condon DJ, McLean N, Noble SR, Bowring SA (2010) Isotopic composition (238U/235U) of
some commonly used uranium reference materials. Geochim Cosmochim Acta
74:7127-7143
Dalrymple GB, Lanphere MA (1971) 40Ar/39Ar technique of K-Ar dating: a comparison with
the conventional technique. Earth Planet Sci Lett 12:300-308
Gerstenberger H, Haase G (1997) A highly effective emitter substance for mass spectrometric
Pb isotope ratio determinations. Chem Geol 136:309-312
Jaffey AH, Flynn KF, Glendenin LE, Bentley WC, Essling AM (1971) Precision measurement
of half-lives and specific activities of 235U and 228U. Physics Review Section C 4:1889-
1906
Koppers AAP (2002) ArArCALC - software for 40Ar/39Ar age calculations. Comput Geosci
28:605-619
Krogh TE (1973) A low-contamination method for hydrothermal decomposition of zircon and
extraction of U and Pb for isotopic age determinations. Geochim Cosmochim Acta
37:485-494
Ludwig KR (1980) Calculation of uncertainties of U–Pb isotope data. Earth Planet Sci Lett
46:212-220
Ludwig KR (2005) Isoplot/Ex. V. 3. USGS Open-File rep
Markey RJ, Hannah JL, Morgan JW, Stein HJ (2003) A double spike for osmium analysis of
highly radiogenic samples. Chem Geol 200:395-406
Markey RJ, Stein HJ, Hannah JL, Zimmerman A, Selby D, Creaser RA (2007) Standardizing
Re-Os geochronology: a new molybdenite Reference Material (Henderson, USA) and
the stoichiometry of Os salts. Chem Geol 244:74-87
McDougall I, Harrison T (1999) Geochronology and thermochronology by the 40Ar/39Ar
method. 2nd edn. Oxford University Press, New York
Mitchell JG (1968) The argon-40/argon-39 dating method for potassium-argon age
determination. Geochim Cosmochim Acta 32:781-790
Renne PR, Swisher CC, Deino AL, Karner DB, Owens TL, DePaolo DJ (1998)
Intercalibration of standards, absolute ages and uncertainties in 40Ar/39Ar dating. Chem
Geol 145:117-152
Rosenblum S, Brownfield IK (1996) Magnetic susceptibilities of minerals. Open-File Report
99-529:37
Schmitz MD, Schoene B (2007) Derivation of isotope ratios, errors, and error correlations for
U-Pb geochronology using 205Pb-235U-(233U)-spiked isotope dilution thermal ionization
mass spectrometric data. Geochemistry, Geophysics, and Geosystems 8:1-20
Steiger RH, Jäger E (1977) Subcommission on geochronology: Convention on the use of
decay constants in geo- and cosmochronology. Earth Planet Sci Lett 36:359-362
Stein HJ, Markey RJ, Morgan JW, Hannah JL, Scherstén A (2001) The remarkable Re-Os
chronometer in molybdenite: how and why it works. Terra Nova 13:479-486
Stein HJ, Morgan JW, Scherstén A (2000) Re-Os dating of low-level highly-radiogenic
(LLHR) sulfides: the Harnäs gold deposit, southwest Sweden, records continental
scale tectonic events. Econ Geol 95:1657-1671
Stein HJ, Scherstén A, Hannah JL, Markey RJ (2003) Sub-grain scale decoupling of Re and
187
Os and assessment of laser ablation ICP-MS spot dating in molybdenite. Geochim
Cosmochim Acta 67:3673-3686
York D (1966) Least-squares fitting of a straight line. Canadian Journal of Physics 44:1079-
1086
York D (1967) The best isochron. Earth Planet Sci Lett 2:479-482

You might also like