You are on page 1of 8

Magmeter Grounding Strategy http://www.flowcontrolnetwork.com/articles/87297-magmeter-groundi...

Thermal Mass Flow Measurement


Coriolis Flow Measurement
Electromagnetic Flow Measurement
Mechanical Seals
Radar Level Measurement
Sight Flow Indication
Temperature Measurement
Variable-Area Flow Measurement
Ultrasonic Level Measurement

View Cart (0 items)

Login

Follow Flow Control Magazine On:


facebook
twitter
youtube
linkedin

Solutions for Fluid Movement, Measurement & Containment

Contact
Subscribe
easurement Advertise

FlowStream Blog
E-News
Flow Control Weekly
Flow Update
Level Update
Pressure Update
Pump Update
Temperature Update
Valve Update
Magazine
Current Issue
Digital Edition
Subscribe
FlowTube Videos
White Papers
Portals
Clamp-On Ultrasonic Flowmeters
Coriolis Flow & Density Meters
Custody-Transfer Measurement
Electromagnetic Flowmeters
Emissions Monitoring
Meter Verification & Calibration
Oil & Gas Measurement
Radar Level Measurement
Sight-Flow Indicators
Steam Systems Management
Thermal Flowmeters
Turbine Flowmeters
Vendor Directory
Supplier Listings
Get Listed
Training Programs
Industrial Flow Measurement Seminar
Pump Guy Seminar
Jobs
View Jobs
Post Your Resume
Post Your Jobs

Topics

Featured Products
Flowmeter
Level Measurement
Pressure Measurement
Temperature Measurement

1 of 8 10-03-2015 15:27
Magmeter Grounding Strategy http://www.flowcontrolnetwork.com/articles/87297-magmeter-groundi...

Filtration
Pump
Valve
Seals & Gaskets

APPLICATION PORTALS: Custody-Transfer Measurement | Emissions Monitoring | Meter Verification & Calibration | Oil & Gas Measurement | Steam Systems
Management TECHNOLOGY PORTALS: Clamp-on Ultrasonic Flowmeters | Coriolis Flow & Density Meters | Magnetic Flowmeters | Radar Level Measurement
| Sight Flow Indicators | Thermal Flowmeters | Turbine Flowmeters
Go
Recent Searches
rocket science/airfilter/paddle flow meter/anderson/isa wireless

Ad by SoftCoup | Close

FEATURED SPONSORS:

Home » Magmeter Grounding Strategy

Magmeter Grounding Strategy


How to protect against magnetic flowmeter reliability issues

By Clifford Read
September 26, 2010
No Comments
Email / Print / Reprints / | More / Text Size+

For any magnetic flowmeter (magmeter) system to function properly it must have three connections (including a ground) to the process liquid passed from the magmeter
flowtube onto the magmeter flow transmitter. About 80 percent of the time, problems with the flow measurement readings provided by a magmeter can be traced directly to
improper solution ground connections.

Two of the three connections are passed from the magmeter flowtube’s measuring electrodes, which sense the energy created
within the magnetic flowtube based on Faraday’s Law, onto the magmeter flow transmitter via the two electrode signal cable leads.
This energy is then represented by the magnetic flow transmitter as a measurement of flowrate. The required third connection to the
process is often referred to as the solution ground, or simply SG. This SG connection is a critical connection from the process liquid
passed over to the body/case of the flowtube and then onto the magmeter flow transmitter via the solution ground lead portion of
the electrode signal cable.

The SG connection is actually the reference point of the measurement, and it is required for a magmeter to consistently achieve a
stable zero flow measurement reading, as well as to provide accurate measurements during flow. Without this reference SG Figure 1. Flanged-style magmeter flowtube

connection, there can be no confidence in the flowrate measurement. installed in metal process pipe.

READ ALSO: Magmeter Basics—A primer on selecting & applying electromagnetic flowmeters

Two main causes are responsible for the majority of solution ground connection problems. First, the SG connection from the
process to the magmeter flowtube’s body/case is missing. Secondly, the SG connection fails to pass properly from the magmeter
flowtube’s body/case onto the magnetic flow transmitter’s SG terminal.

Magmeter Grounding Rings vs. Grounding Electrodes

In order to determine when to use grounding rings or grounding electrodes, the first thing that must be understood is their primary
function, and if they are even required. The primary function of grounding rings or grounding electrodes is to provide the required
SG connection when unlined metal process pipe is not available. Grounding rings are metal rings that make contact with the
Figure 2. Typical wafer-style magmeter flowtube
process liquid.
with supplied SG wires installed in flanged metal
process pipe.
These rings are installed between the process pipe and the magmeter flowtube. These metal rings must then be attached to the
flowtube’s body/case or flange in order to pass on this SG connection—usually by some wiring or bolting method, depending on the style of grounding ring used. Examples wi th
detailed illustrations are shown in this article. In addition to providing the required Solution Ground, a grounding ring on the upstream side of the magmeter flowtube also
provides a fair degree of liner protection to the leading edge of the flowtube’s liner when used in moderately abrasive applications.

2 of 8 10-03-2015 15:27
Magmeter Grounding Strategy http://www.flowcontrolnetwork.com/articles/87297-magmeter-groundi...

Figure 3. Flanged-style magmeter flowtube with SG grounding straps and rings installed in nonmetallic pipe.

Magmeter grounding electrodes are simply one or more additional electrodes, other than the flowtube’s measuring electrodes, that contact the process liquid while also mak ing
contact with a metallic portion of the flowtube’s body/case. When using a flowtube with grounding electrodes, no additional wiring is required to pass the SG connection o nto
the flowtube’s body/case—it is done internally. When using flowtubes that already contain grounding electrodes, grounding rings are not normally required.

Figure 4a. Magmeter liner protection (grounding) rings used for both liner protection and
process fluid grounding with PTFE.

For many of the more hazardous process liquid applications, magnetic flowmeter systems are often the preferred technology simply because they are available with numerous
liner and exotic electrode material choices, thus providing compatibility with many hazardous chemicals. If grounding rings or grounding electrodes are required, they should be
made from the same material as the measuring electrode based on chemical compatibility with the process liquid.

In hazardous process liquid applications, the adjacent process piping is usually nonmetallic or lined. Because grounding rings made from exotic materials are rather expensive,
grounding electrodes can offer substantial cost savings over grounding rings and provide easier installation with fewer leak-points.

Figure 4b. Magmeter liner protection (grounding) rings with Neoprene, EPDM, Linatex, or
Ebonite.

Contact the supplier to determine which flowtube models are available with grounding rings and/or grounding electrodes.

Does the Magmeter Need 1 or 2 Grounding Rings?

For decades, two grounding rings were always the recommendation when required for magmeters. When using older style legacy magnetic flow transmitters, this is still true.
However, with current intelligent microprocessor-based magnetic flow transmitters, two grounding rings are no longer necessary, as the same level of zero stability and accuracy
can be provided with just one grounding ring. This not only reduces the overall cost of materials, but also makes installation easier.

When using one grounding ring, it should be placed on the upstream side of the magmeter flowtube. In addition to providing the required solution ground, placing this
grounding ring on the upstream side of the flowtube also provides a fair degree of liner protection to the leading edge of the flowtube’s liner when used in moderately ab rasive
applications.

How Magmeter Flowtube Installation Affects the Solution Ground

Proper flowtube installation is critical for correct SG in magmeters. In the case of metal process piping, a properly installed flowtube means that no additional solution grounding
rings or electrodes are required. For nonmetallic pipe or liner configurations, a solution ground method is required, and careful attention must be paid to grounding ring or
electrode connections and placement. The following provides some tips for proper SG connections to the magnetic flow transmitter.

3 of 8 10-03-2015 15:27
Magmeter Grounding Strategy http://www.flowcontrolnetwork.com/articles/87297-magmeter-groundi...

SG Connection with Metal Process Pipe


Flanged-style flowtubes: The most common method of passing the SG connection from the process itself onto the magnetic flowtube’s body/case is through flanged, unlined,
metal process pipe bolted to a flanged magnetic flowtube (Figure 1).

When the metal flanges on each side of the magnetic flowtube are bolted to the magnetic flowtube’s metal flanges, the SG connection is made. It passes onto the magnetic
flowtube’s body/case, and eventually to the magnetic flow transmitter. In this metal-to-metal installation scenario, neither grounding rings nor grounding electrodes are
required.

Wafer-style flowtubes: Wafer style flowtubes have no flanges of their own. Therefore, when a wafer-style magnetic flowtube is mounted between flanged, unlined, metal
process piping, the proper method of passing the SG onto the flowtube is by attaching supplied SG wires that ship with the flowtube. Be sure to connect these wires to the metal
process pipe flanges on each side of the wafer flowtube (Figure 2).

In this installation scenario, grounding rings are not required. Note that grounding electrodes are not available on wafer-style magnetic flowtubes; the supplied wires ar e to be
used.

SG Connections with Nonmetallic/ Plastic/PVC/Lined Process Pipe


Flanged-style flowtubes: When flanged-style flowtubes are mounted between nonmetallic, plastic, PVC or lined process piping, the SG must be passed to the flowtube’s
body/case through some path other than the process piping flange bolts. In such installation scenarios, either grounding rings or grounding electrodes are required (Figure 3).

For grounding-ring applications, if traditional orifice plate-style, or Type C, grounding rings are used, the
grounding rings must be attached to the flowtube’s body/case using grounding straps. These straps are attached
to the flowtube’s flanges, or to grounding wires attached to a lug located on its remote junction box or
top-mounted transmitter interface plate. Type E grounding rings utilize customer-supplied bolts, rather than
grounding wires or grounding straps.

For process pipe that is lined with a nonmetallic material, the ring configuration is slightly different. Figure 4
shows the application of Type E and Type C grounding rings in lined process pipe configurations.

Wafer-style flowtubes: When wafer-style flowtubes are mounted between nonmetallic, plastic, PVC or lined
process piping, grounding rings are required. The SG must be passed on to the flowtube’s body/case by
connecting the attached, supplied SG connection wires to the grounding rings (Figure 5.)
Figure 5. Magmeter wafer-style flowtube installed in non-metallic pipe

As with flanged flowtubes, if traditional orifice plate-style, or Type C, grounding rings are used, the grounding (bolts not shown).

rings must be attached to the wafer-style flowtube’s body/case using grounding straps or wires. The grounding
wires are attached to a lug located on its remote junction box or top-mounted transmitter interface plate. Type E grounding rings utilize customer-supplied bolts rather then
grounding wires or grounding straps.

It is important to remember the purpose of the solution ground connection is to serve as a reference point of the flow measurement. This lets the magnetic flowmeter read a
stable zero flow and achieve accurate measurement in flow conditions. The placement and type of SG and connection devices is critical in meeting this goal. The method used
varies with the range of flowmeter body types, process pipe construction and liner materials. When all of these factors are considered, and the proper SG configuration is
employed, results will meet performance and consistency expectations. Without a properly installed solution grounding method, confidence in the flowrate measurement will be
diminished.

Clifford Read is a technical support engineer in the Field Devices Technical Assistance Center for Invensys Process Systems. He has been involved in the process control
industry for 24 years, and his primary focus for the past eight years has been on flow product application consulting and troubleshooting. Additional fields of expertise include
instrument configuration software/hardware marketing support, testing, as well as client-side troubleshooting support. Mr. Read can be reached at 508 549-4540.

www.ips.invensys.com

Email
Like Share 0 Tweet 3 Share

You must login or register in order to post a comment.

Related Articles

Related Articles

Magmeter Basics

E+H Breaks Ground on Magmeter Mfg. Facility

In Magmeters We Trust

4 of 8 10-03-2015 15:27
Magmeter Grounding Strategy http://www.flowcontrolnetwork.com/articles/87297-magmeter-groundi...

Flow Control Magazine


CURRENT ISSUE | DIGITAL EDITION
SUBSCRIBE

MOST POPULAR

Popular
Recent Comments
Emailed

Part I: An Insider’s Guide to Valve Sizing & Selection

Flowmeters for Oil & Gas Measurement

Part II: An Insider’s Guide to Control Valves & Process Variability

Intelligent Pumps Evolve with Smart VFDs and Connectivity

Knowing the Whens and Whys of Flow Measurement to Ensure Solution Success

LNG’s Role in the Natural Gas Marketplace

Venturi Flowmeter Helps Improve Water Quality in the Potomac River

3 Ways You Can Help Girls Get Involved in STEM

How Bi-Directional Pressure Sensors Facilitate Vapor Recovery in the Oil Industry

Key Considerations for Using Biodegradable Hydraulic Fluid

5 of 8 10-03-2015 15:27
Magmeter Grounding Strategy http://www.flowcontrolnetwork.com/articles/87297-magmeter-groundi...

Multimedia

Videos

Videos

More Videos

EVENTS

Pump Guy Seminar - Indianapolis, Ind.


June 16, 2015 to June 18, 2015
Location: Endress+Hauser Process Training Unit, 2355 Endress Place

Industrial Flow Measurement Seminar - Boston


June 23, 2015 to June 25, 2015
Location: University of Phoenix
David W. Spitzer
More events
MORE EVENTS

Flow Control Career Center

More Jobs | Post a Resume | Post a Job

LATEST JOBS

ER09 - Mechanical Engineer


Evans, Georgia
Kelly Engineering Resources
Principal Environmental Technologist - Philadelphia, PA
Philadelphia, Pennsylvania
CH2M HILL
Mechanical Engineer Fiber Optics
New London, Connecticut
Kelly Engineering Resources
View All Jobs

What is your company's position on mobile solutions for plant and/or field-based data access?

6 of 8 10-03-2015 15:27
Magmeter Grounding Strategy http://www.flowcontrolnetwork.com/articles/87297-magmeter-groundi...

What is your company's position on mobile solutions for plant and/or field-based data access?
We are currently using mobile solutions
We are considering/evaluating mobile solutions
We are not using or considering mobile solutions

View Results Poll Archive

Ad by SoftCoup | Close

Back to Top
Go

CONTENT SECTIONS
FlowStream Blog
Featured Products
The Magazine
FlowTube Videos
White Papers
Flow Control Career Center
REGULAR CONTRIBUTORS
Larry Bachus
Amy W. Richardson
Matt Migliore
David W. Spitzer
Jesse Yoder
BUYER'S RESOURCE
Supplier Listings
Get Listed
Manage an Existing Listing
PUMP GUY SEMINAR
About the Seminar
Course Outline
Register Now
SUBSCRIBE
Magazine
E-Newsletters
Premium Content
ADVERTISE
Media Kit
Job Listings
Directory Listings
Advertising Contacts
MORE
Editorial Submissions Guidelines
Editorial Calendar
Request Article Reprints
Contact Us
Privacy Policy

Facebook
Twitter
LinkedIn
YouTube

Copyright

© 2015 EBSCO Industries, Inc. All rights reserved. Grand View Media Group is a subsidiary of EBSCO Industries, Inc..
You may not download or reproduce any images on this site without written permission from GVMG admin for anything other than personal use.
Design, CMS, Hosting & Web Development :: ePublishing.
Coming Soon...To find out how you can sponsor a Flow Control Technology or Application Portal, please e-mail FlowControl@GrandViewMedia.com.

7 of 8 10-03-2015 15:27
Magmeter Grounding Strategy http://www.flowcontrolnetwork.com/articles/87297-magmeter-groundi...

Ad by SoftCoup | Close Ad by SoftCoup | Close

8 of 8 10-03-2015 15:27

You might also like