TEST CERTIFICATE al
@aEa™365 53 GRADE ORDINARY PORTLAND CEMENT auas / ams / PR /F09
Despatch Date: W.No- 28
09/07/2018 TO 15/07/2018
Issued To
REQUIREMENTS, RESULTS ‘SPECIFICATIONS
‘OBTAINED AS PER IS:269-2015
PHYSICAL TESTS
1) FINENESS OF GRINDING
Specific Surface by Blaines Air Permeability apparatus 326 | Not less than 225 M2/ kg.
2) COMPRESSIVE STRENGTH
One part of cement with 3 parts Standard Sand IS 650 / 1991]
3 days 309 | Not ess than 27 Mpa
7 days 411 _ | Not less than 37 Mpa
28 Days 588 Not less than 53 Mpa
3) SETTING TIME : By Vicat Apparatus
INTIAL 129 | notless than 20 Minutes
FINAL 219 | not more than 600 Minutes
4) SOUNDNESS : UNAREATED CEMENT
a) Lechatelier's Mould 12 Not more than 10 mm
5) By Autoclave apparatus 0.065. | not more than 0.8%
CHEMICAL ANALYSIS
1) Loss onignition LO! 197 | Not more than 4.0%
2) Magnesium Oxide MgO 1.63 | Not more than 6.0%
3) Sulphuric Anhydride SO3 2.03 | Not more than 3.5 %
4) Insoluble Residue IR 1.82 | Not more than 5.0%
S)LSF=%Ca0-(0.7%S03)/2.8*SI02+1.2*AI203+0.65*FE203, aga] Not more than 3.02 and Not Less than
6) Al203 / Fe203 1.19 | Not less than 0.66
7) Chlorides a 0.01 | Not more than 0.10%
8) C30 6.45
For Chettinad Cement o Pvt Ltd,
Hastings A
Prepared By General Manager (QUAS )