You are on page 1of 1
e Chethnad CHETTINAD CEMENT CORPORATION PVT LTD @ coment WORKS:RANI MEYYAMMAI NAGAR, KARIKKAL! POST “20s (VIA) GUZILLIAMPARAI, DINDIGUL DIST, PINCODE:624703 oes, : TEST CERTIFICATE al @aEa™365 53 GRADE ORDINARY PORTLAND CEMENT auas / ams / PR /F09 Despatch Date: W.No- 28 09/07/2018 TO 15/07/2018 Issued To REQUIREMENTS, RESULTS ‘SPECIFICATIONS ‘OBTAINED AS PER IS:269-2015 PHYSICAL TESTS 1) FINENESS OF GRINDING Specific Surface by Blaines Air Permeability apparatus 326 | Not less than 225 M2/ kg. 2) COMPRESSIVE STRENGTH One part of cement with 3 parts Standard Sand IS 650 / 1991] 3 days 309 | Not ess than 27 Mpa 7 days 411 _ | Not less than 37 Mpa 28 Days 588 Not less than 53 Mpa 3) SETTING TIME : By Vicat Apparatus INTIAL 129 | notless than 20 Minutes FINAL 219 | not more than 600 Minutes 4) SOUNDNESS : UNAREATED CEMENT a) Lechatelier's Mould 12 Not more than 10 mm 5) By Autoclave apparatus 0.065. | not more than 0.8% CHEMICAL ANALYSIS 1) Loss onignition LO! 197 | Not more than 4.0% 2) Magnesium Oxide MgO 1.63 | Not more than 6.0% 3) Sulphuric Anhydride SO3 2.03 | Not more than 3.5 % 4) Insoluble Residue IR 1.82 | Not more than 5.0% S)LSF=%Ca0-(0.7%S03)/2.8*SI02+1.2*AI203+0.65*FE203, aga] Not more than 3.02 and Not Less than 6) Al203 / Fe203 1.19 | Not less than 0.66 7) Chlorides a 0.01 | Not more than 0.10% 8) C30 6.45 For Chettinad Cement o Pvt Ltd, Hastings A Prepared By General Manager (QUAS )