MK. JUCHHEIM UK
‘Gmbii & Co Sumo
36035 Fulda, Germany
Phone (os) 2000-0,
Fax (oss) 6003-607
‘oiex 4970) jura Fae
‘oma JUMO_Se@e-malicom
wstrument Co, Lid.
Tempo Bank, Riverway
Hanw essed CMO 217
Phone (07278) 638533
3278)
usa
‘Jame Process Control Inc.
735 Fox Chase
‘Goatesvite PA 10320
Phone 6 16-380-8002,
282 800-954 UMO
Fax 690-380-8009,
MEASUREMENT AND CONTROL
PEE
Pressure and differential pressure switch
Type 4ADS-10
Application
Differential pressure ewitches 4ADS-10 are
‘used mainly for monitoring air and ol fiters in
Compressor installations. Because of their
rugged construction they have numerous
adgtional applications in all areas of process
Technology where ferential pressures have
‘to be montored. The unis can also be used
aspressuroor vacuum suitehesbyeonnecting
Up only one of the pressure connections.
Type designation
4a0s-10
2 Pressure instrament
s surface mount
bs rosso and diferent
Brossure srtsh
30 housing 100mm da,
Extra Codes
1 restrictor in pressure uct
ns Setering penis vacuum
inesn-$0 mbar and
‘Ober
19 accuracy 129%
Swrtcrng afore 109%
att ewtening pot seting
150 Protection F's
Ordering example
Pressure and differential pressure switch
‘Type 4ADS-10147/50
Switching point: 2 bar
Construction
‘Two aluminium die-cast housing shele form
two independent pressure chambers in
Conjunction with a’ separating diaphragm,
rivetted pressure plates and springs.
Operation
Acchangeofpressurein thepressurechambers
Causes axial movementofaplunger.Asingle
polemicroswitch is operated when afactory-
‘Set pressure diference has been reached.
1,99/00073100
Technical data
Housing
‘aluminium die-casting GD-AISi@Cud
Pressure connection
2 female threads ',” pipe
Restrictor in pressure duct
sintered disc with restriction hole
with Code 0%
Diaphragm
‘aconitile-butadiene rubber (NBR)
‘esistant to: Diesel fue, mineral ol, ol
bboaring air, heating ol, water
Cable entry
Patt cable gland
Electrical connection
{aston tags 6.3 x 0.8 mm to DIN 46 248/A
for angle connectors
‘Type of contact
single-pote changeover microswitch (CSA,
and UL approval)
Protection
normally P43
(Code /80 P54
‘Mounting
bby 2 holes M6 x 10 atthe back
Operating position
unrestricted
‘Switching point
Permanently set atthe factory
‘The exact value of the switching point
‘must be specified when ordering.
Prossure and differential pressure switch
‘switching points normally from 50 mbar to
Sar
Vacuum switch, Code /48
from -0 mbar to -800 mbar.
‘overioad limit: -1 bar
Switching point accuracy
normaly +59%
Code 492%
‘Switching aitferential
‘normally 30% of switching point setting
Code /49: 10% of switching point setting
= 1
7) |
Contact rating
250Vac. 108, pf =1
250Vde.0.25A
W25Vde,05A
Pormitted ambient temperature
480°CDimensions
‘mm | inch |
08] 0.031 |
63) 0.25
13 | 051
26 | 1.02
a2 | 165 |
a | 327 |
36 | 339
106_| 17
1.93/00073100
Connection to
Pressure and
differential pressure
positive 1
egative 2
Vacuum 48
1