SLNo. Annexure-1 Energy Engineering Gadgets Item Description aty PYRANOMETER lackbody Thermopile Classification :ISO 9060:2018 Class C Spectral Range : Upward-looking: 385 to 2105 nm Downward-looking: 295 to 2685 nm Response Time:0.5 seconds Error Due to Clouds:+ 2 % Temperature response: 4% deviation due to change in ambient within an interval of 50k, Achievable uncertainty(959% confidence level) ‘ANEMOMETER Spec: Very sensitive cup vane system Wind direction is of no importance Ingress protection IP 65 MIN, MAX and HOLD functions Auto shutoff _ Anemometer with large LCD CUP ANEMOMETER Spec: Range ~5 to 180 km/hr Supply ~ 2200r110V, AC 50 HZ Display~3-¥ digit LC.D MINI BLOWER ‘Spec: Pressure ~ 108 Blower Type — Turbo Blower Power - hp Body material ~ cast iron Airflow ~ 645 SCFM PRESSURE GAUGE Spec: Model : AL-Series Dial Size : 40, 50, 63, 80, 100, 150, 250 MM MOC: Complete $5, Brass $5, Commercial Accuracy : 0.5 %, 1%, 1.6%, 2.5 % Mounting : Bottom, Back, BCPL, Back With Clamp SOLARIMETER Spec: Weight- 60gCell rensions - 30 x 32 mm Cable Length - 1,25 m temperature - from -10°C to +50°C Storage temperature -from -10°C to +55°C Package dimensions - 58 x 120 x 33 mm SOLAR INSULATION TANK Spec: Storage capacity- 0- 250 L Storage material - water gas , chemicals, oils Tank orientation — horizontal , vertical Structure - vertically Installation type ~ floor mounted Material - stainless stee! SILNo. Item Description aty PYREHELIOMETER Spec: The new MS-S7 pyrheliometer is a unique pyrheliometer compliant to the "Fast reponse” and "Spectrally flat” sub-category under IS09060:2018 Class A, The pytheliometer is a breakthrough in unprecedented low thermal offset behavior and fast thermopile response (< 0.2s / 95%). MS-S7 FirstClass isa direct normal incidence (DNI) solar irradiance sensor. Also known as a pyrheliometer, itis used as a reference sensor for routine operation on a Solar Tracker. The all-weather MS-57 is responsive to solar irradiance in the spectral range from 200 ~ 4000nm and works under the most extreme conditions in a temperature range from ~40°C - 80°C, The integrated low power window heater can prevent dew deposition or frost on the outside window. Solar Water Heater Student Laboratory Test Rig Spec: Capacity: 50 Its. 10. Solar Air Heater Student Laboratory Test Rig Spec: ‘Temperature : 50 to 100 °C 11, Solar Cooker Student Laboratory Test Rig ‘Spec: ‘Temperature: 100 °C to 1508C 12. Solar Power plant Student Laboratory Test Rig Spec: Range: 2 KW

You might also like