Performance of Grid-connected PV

NOTE: before using these calculations for anything serious, you should read [this]

PVGIS estimates of solar electricity generation

Location: 44°32'18" North, 28°36'40" East, Elevation: 61 m a.s.l.,

Solar radiation database used: PVGIS-CMSAF

Nominal power of the PV system: 5.0 kW (crystalline silicon)


Estimated losses due to temperature and low irradiance: 10.5% (using local ambient temperature)
Estimated loss due to angular reflectance effects: 2.9%
Other losses (cables, inverter etc.): 14.0%
Combined PV system losses: 25.3%

Fixed system: inclination=35°, orientation=0°


Month Ed Em Hd Hm
Jan 8.39 260 2.03 62.9
Feb 12.50 350 3.10 86.7
Mar 17.90 556 4.63 143
Apr 20.70 622 5.55 166
May 22.70 702 6.21 193
Jun 23.20 695 6.47 194
Jul 23.40 724 6.58 204
Aug 23.00 714 6.52 202
Sep 19.20 576 5.29 159
Oct 15.40 478 4.06 126
Nov 10.60 317 2.67 80.0
Dec 7.68 238 1.87 58.1

Yearly average 17.1 519 4.59 140


Total for year 6230 1670

Ed: Average daily electricity production from the given system (kWh)
Em: Average monthly electricity production from the given system (kWh)
Hd: Average daily sum of global irradiation per square meter received by the modules of the given system
(kWh/m2)
Hm: Average sum of global irradiation per square meter received by the modules of the given system (kWh/m 2)

PVGIS © European Communities, 2001-2012