1. A Goniometer is a type of which of the following measuring devices?

Radiometer

Photometer

Refelectometer

Photomultiplier Tube
2. An electron microscope can be used to study structures down to a sensitivity of which of the following?

Wavelength of visible light

10 angstroms

Wave length of infra red radiation

Wave length of uv-c radiation


3. What type of magnifier lens is housed in a simple surface comparator?

Triplet x 50

Doublet x 10

Doublet x 3.5

Triplet x 10
4. Which type of microscope uses the wavelength light as a unit of measure for surface contours and characteristics?

Interference microscope

Polarizing microscope

Phase contrast microscope

Metallographic wide field microscope


5. The fibres which are used in the image guide of a videoboroscope need to be kept in which of the following bundles?

Incoherent bundle 30 microns diameter

Coherent bundle 30 microns diameter

Coherent bundle 9 microns diameter

Incoherent bundle 9 microns diameter


6. The contrast rings which are attached to the electrical cord on a rigid boroscope serve which of the following purposes?

Viewing at 90 degrees to the forward direction

360 degrees rotation of the scope

Greater depth of field

Help hold the lens system rigid


7. For what purposes are neutral density filters used?

Transmission of electromagnetic waves below a set threshold

To block out radiation except for visible wavelength

Transmission of electromagnetic waves above a set threshold

To attenuate a light level from a source which is difficult to control


8. Which of the following filter types smooths abrupt transitions in an image to give a better picture?

Low pass spatial filter

High pass spatial filter

Media spatial filter

Neutral density filter


9. The topography of a fracture surface can be replicated and analysed using cellulose acetate tape with a transition electron
microscope up to what maximum magnification?

10000 x

50000 x

500 x

25000 x
10. Which of the following acids which could be used to etch the surface of metals need to be contained within inert plastic
containers?

Hydrochloric acid

Suplhuric acid

Nitric acid

All of the above


11. Which of the following detection devices works on the principle that change in resistance of the cell can be detected?

Photo emissive

Charged coupled device

Photo conductive

Photo voltaic
12. Which of the following films would require the least light?

400 A.S.A.

1000 A.S.A.

200 A.S.A.

100 A.S.A.
13. Which of the following could be measured with a cambridge weld guage?

Excessive re-inforcement

Weld preparation angle

Undercut

All of the above

Excessive re-inforcement and Undercut only


14. Which of the following would calculate the theoretical throat?

Leg length x 1.41

Leg length x 0.707

Leg length / 1.14

Leg length / 0.707


15. When using light emitting diodes on a video borocsope to produce a black and whit image, which colour is most likely to be
used due to response and intensity?

Blue

Yellow

Red

Green
16. Which of the following cameras would be the preferred choice for operation within a high radiation environment?

Charge couple device

Vidicon tube

Orthicon tube

Metal oxide semiconductor


17. Which of the following replicating materials would be best used to produce an impression of a relatively rough surface?

Cellulose acetate

Clay

Silicone rubber

All could be used


18. What is the replica called which is made from the first cast of an impression such as footprint?

Single stage

Second stage

Positive

Negative

Single stage and second stage

Positive and Negative


19. If a replica made from cellulose acetate is to be viewed under a scanning electron microscope with which of the following
materials are the replicas coated to prevent electron charging?

Nickel

Cobalt

Gold

Iron

Nickel and Cobalt


20. In which of the following forms are temperature indicatiing materials available?

Pellets

Crayon stick

Organic liquids

All forms above are available


Here are your corrections:

1. Photometer
2. 10 angstroms
3. Triplet x 10
4. Interference microscope
5. Coherent bundle 9 microns diameter
6. 360 degrees rotation of the scope
7. To attenuate a light level from a source which is difficult to control
8. Low pass spatial filter
9. 50000 x
10. Nitric acid
11. Photo conductive
12. 1000 A.S.A.
13. All of the above
14. Leg length x 0.707
15. Red
16. Vidicon tube
17. Silicone rubber
18. Positive and Negative
19. Gold
20. All forms above are available