INCLINATOR
COMPANY Or /\AMERICR
HARRISBURG, PA
RO REFEREN
PROJECT: HOMEWAITER 120#
MACHINE BELOW
TYPICAL DRAWING FOR REFERENCE ONLY.
NOT TO BE USED FOR CONSTRUCTION
SPecirications
MODEL: HOMEWAITER (COLLAPSIBLE GATE W/SWING TYPE DOOR)
LANDINGS: 2
CODE(S): 1
CAPACITY: 120
SPEED: 28 F.P.M
PLEASE. REFER ANY QUESTION TO YOUR
‘SALES. REPRESENTATIVE
SUSPENSION 1 WIRE ROPE:
MEANS 5/32 AIRCRAFT CABLE Doarrroven
(unarrrovep
CAR CONSTRUCTION: AVAILABLE IN STAINLESS STEEL,
PAINTED STEEL OR HAROWOOD” VENEER
Nereb'on THe coNrTRuIng OnER SHEET Tana
|DISGLAIMER: ONCE DRAWINGS HAVE BEEN APPROVED,
SIGNED AND WITHIN 5 DAYS OF PRODUCTION, THE
CUSTOMER WILL BEAR ALL RESPONSIBILTY ANO LIABILITY]
OF FINISHED UNM.
OE
We VIEW PART NUMBER REV.DATE
COVER SHEET TYPICAL —
INSEINGTOR| DRAWING TITLE, DRAWING NO =
[neon HW 120 CODE 1 HW =
PAGE: DRAWN BY: | DWG. DATE [JOB OR APP.#PEALER P.O. DWG. SCALE |REV.LEVEL(1—3)
1/4 B.BRATTEN JAN, 14 = = 1:24 =SEE "LOAD CAPACITY CALCULATOR”
FOR OTHER POSSIBLE
HW 120# CAB DIMENSIONS
Lpoor ITERLOCK
(SEE PG.4 DETAIL)
UNISTRUT |& GUIDE RAIL
FINISHED
POST GATE
[AND LOCAL CODES.
‘ALL HOISTWAY CONSTRUCTION MUST COMPLY WITH NATIONAL, STATE,
HOISTWAY MUST BE PLUMB AND STRAIGHT
FROM TOP To BOTTOM WITH NO PROJECTIONS INTO. THE HOISTWAY,
NOTICE TO ELECTRICAL CONTRACTOR:
“ALL ELECTRICAL WIRING VUST BE DONE BY A JOURNEYMAN MECHANIC
“BRING (2) #12 W/GND FROM RESIDENCE INCOMING POWER PANEL 20AMP GFi BREAKER(120V, NEUTRAL, GROUND)TO THE MACHINE ROOM
REQUIRED LOW VOTAGE WIRING 1S SUPPLIED BY VANUFACTURER. ALL EXTENSIONS ADDITIONS, ETC. SHALL BE DONE WITH THE SAME SIZE
‘AND TYPE OF WIRE AS ORIGINALLY SUPPLIED GY THE MANUFACTURER
ALL MEANS FOR ACCESS TO EQUIPMENT SHALL BE PROVIDED WITH A LOCK, ALL SHAFT DOORS MUST BE INTERLOCKED.
AND MUST MEET ALL NATIONAL, STATE, AND LOCAL CODES.
DWG VIEW PART NUMBER REV.DATE,
HOISTWAY LAYOUT TYPICAL —
INGUING@TQR) DRAWING TITLE DRAWING NO. =
fee HW 120 01 =
DRAWN BY: | OWG. JOB OR APP.#PEALER P.O. DWG. SCALE |REV.LEVEL(1—3)
PAGE:
2/4
B.BRATTEN | JANIM_OVERHEAD_ NO}
OVERHEAD MAY BE REDUCED TO” MINIMUM
OF 4” ABOVE TOP_OF CAR BY LOWERING
SHEAVE ON RAL,
p80
2a
poor
36"
couNTeR
felon —
35°
wax —
TRAVEL -
24"
poor
36" osNe woHNE
COUNTER yee ‘CONTROLLER
HEIGHT 4
WACHINE ROOM. CAN
We UES tose
OF aE.on Holst
DWG VIEW PART NUMBER REV.DATE
SECTION A-A TYPICAL —
WEIN ATSIS) DRAWING TITLE. DRAWING NO. =
|mana HW 120 DE 1 HW—O' =
PAGE: DRAWN BY: | DWG. DATE [JOB OR APP.#PEALER P.O. DWG. SCALE |REV.LEVEL(1—3)
3/4 B.BRATTEN JAN. 14. = = =UNISTRUT AND
GUIDE RAIL;
UNISTRUT WIDTH SHALL, BE
EQUAL TO WIOTH OF CAR,
RAUL DETAIL
SEE "LOAD CAPACITY CALCULATOR”
FOR OTHER POSSIBLE
HW 120# CAB DIMENSIONS
le
14
i
T
HOISTWAY DOOR
THRESHOLD
why
SHEETROCK e
SIDE VW
1. MACHINE ROOM SIZE REQUIREMENTS
MAY CHANGE WITH TRAVEL DISTANCE
Door FRAME —|
2. MACHINE ROOM CAN BE LOCATED
ABOVE OR BELOW HOISTWAY
2
3. SHEAVE COMBINATIONS
DOOR SILLS TO BE INSTALLED BY G.C. WILL CHANGE WITH ALTERNATE
AFTER LIFT SUPPLIER HAS INSTALLED MACHINE ROOM LOCATIONS
A RUNNING PLATFORM
SILL DETAIL 120# HOMEWAITER MACHINE DIMENSIONS
RAIL FORCES:
2°xa" stuo—|
3" MINIMUM REQUIRED FOR
iNcoa EM~7 "DOOR LOCK.
caB
~~
RUNNING —|
CLEARANCE.
DOOR FRAME DETAIL
78 Las. PULL OUT
400 LBS. (STATIC) VERTICAL LOAD
800 LBS. (IMPACT) VERTICAL LOAD
REACTIONS ON DIRECTIONAL SHEAVES:
(sramic)
(pact)
200 Las.
400 LES,
waxiwuM
PULLOUT FORCE ON GEARBOX ANCHOR: 281 LAS.
TECHNICAL DATA
DWG VIEW PART NUMBER REV.DATE,
DETAILS, DATA, CODES. TYPICAL, —
INGUING@TQR) DRAWING TITLE DRAWING NO. =
fee HW 120 CODE 1 HW—0 =
PAGE: DRAWN BY: | OWG. DATE [JOB OR APP.#IDEALER P.O. DWG. SCALE |REV.LEVEL(1—3)
4/4 B.BRATIEN | JAN. 2014 = = 1:24 =