bo “do wrt fo sto ato TreaT WaT -CIMFR TESTING CELL
ee sn)
omens
aa WS, TAaTE — 826001 (NG) - BARWA ROAD, DHANBAD-826 001 (INDIA)
UL Wao UT - TEST CERTIFICATE
TFORM NO.: CMRI: DQM:FLPO2:F-02]
LD No, 344/08 CODE NO FLP/112A/08-9
FIRST SCHEDULE
{For assoclation with the report of test sent (under cover of this office Letter No CIMFR/TC/P/742
Dated 27" November,2008) to M/S. Micro Industries, 74, Gajera Chambers, Opp. Arvindpark Society,
Behind Anil Starch, Bapunagar Ahmedabad - 25 in respect of testing as regards intrinsic safety of the
equipment mentioned below submitted by them.)
DESCRIPTION OF THE APPARATUS: Intrinsically Safe Safety Torch, Type: MI-T-O1P.
This Torch consists of a brass tubular pipe, body, cover, ring, reflector, bulb holder, acrylic sheet (light
transmitting part) etc. The torch works on 3 nos. of 1.5 volt dry cells or 2 nos. of 1.5Volt dry cells. The
filament bulb of the torch is rated at 3.6 volt and 0.47A/0.5 Amp. The bottom surface of the acrylic disc
just touches the tip of the bulb which rests on a spring loaded device to act as a circuit breaker in the
‘event of breaking of bulb. The acrylic sheet (Smm thick) is protected by wire guard in the ring as shown
in the drawing, For further details the drawing mentioned below may be consulted.
PLICANT: M/S. Micro Industries,
74, Gajera Chambers, Opp. Arvindpark Society,
Behind Anil Starch, Bapunagar
Ahmedabad - 25 (Gujrat)
MANUFATURER: ‘Same as above.
DRAWING:
[sl Drg. No. Date Title
[2 (01/08/08 | Intrinsically Safe Torch up to 3 Cells Type: MI-T-01P 7
Applicable Zone & Gas Group: Zone 1 & 2 and Gas Groups: IIA & IIB only.
TEMPERATURE CLASS : T6 at 40°C ambient
STANDARD REFERENCE: _ IS: 5780-2002 and IS: 13346-2004
‘SECOND SCHEDULE
Following are the permissible variations to the 3 Cell Capacity “Intrinsically Safe Safety Torch, Cat. No.
‘TCH/0B/180 under reference:
1) Alternatively material of construction of the Body, Pipe, front cap, ring and cover of the Safety
Torch may stainless stee! in stead of brass.
2) Alternatively by reducing the lenath of the pipe only, the Safety Torch may be used with 2 nos.
dry Cells and all arrangement will remain same.
GB
204