You are on page 1of 20
NINININING NINN FRINFNINININININ NINING NINININING Wi TAB INININININS NINININING ZNAZNINZNZN Telkom ws NAN wns NAN wus s N s ss NAN wns NAN wns BANANA NANANANININININANINININININIZNZNYZ Indonesia NININININININININININININININININININ ININININININININININININININININININ eH norvore CERTIFICATE OF CALIBRATION isin: PT TELEKOMUNIKASI INDONESIA Tbk Cibinong.: J. Raya Narogong Cileungsi KM. 26:5 Bogor 16820 Phone 021-8231100 Fax. 021-8236000 APProved Signatory Medan : J Gaharu No. 1 Medan 20235 Phone O61-4531311 Fax. O6I-4147434 Surabaya : J. Gayungan PTT No. 17-19 Surabaya 60235 Phone. O31-8283678 Fax. O3I-8283388 ; Makassar : J AP Pettarani No, 4 Makassar 90221 Phone O411+864444, 880444 Fax. O4i)-86N89 = M. Ilyas Date of Issue Submitted by ‘Attention Description Manufacturer/Model Serial Number Environment Calibration Location Date Calibrated Recommended Due Date Date Received Method of Calibration : 21-Nov-2017 PT. TELEKOMUNIKASI INDONESIA, Tbk. Divisi Digital Service Jl. Gegerkalong Bandung + Manager Infrastructure Quality Assurance DDS : OTOR JOSU / MTS 4000 + 0-002 : 23°C / 10%RH + InHouse : 20-Nov-2017 19-Nov-2018 : 07-Nov-2017 ‘The calibration was carried out based on the established Standard Telkom MSC Calibration Procedure, TCL-WI-0002 and by comparison against the following standard(s) and instrument(s) which is (are) calibrated on schedule to ‘maintain traceability and required accuracy Description Reference Fiber A Reference Fiber 8 Reference Fiber C Reference Fiber D sin Cal Date Due Date 4487-21 07-Jan-2017 06-Jan-2018 4agg1-21 07-Jan-2017 06-Jan-2018 44487-21 07-Jan-2017 06-Jan-2018 44490.21 07-Jan-2017 06-Jan-2018 Page t of20 ‘The instrument stated above hae been verified under the environmental condition as stated using Telkom Calibration Laboratory standard. The result of certificates reported on the attached certificate data, This report shall nat be reproduced without the written approval ofthe laboratory CERTIFICATE OF CALIBRATION Toten OE Checked by Certificate number : CCL/17/0951/DY Range Verification OTDR Center Wavelength (Aotdr) —- am OTDR Resolution (res) 1 m Reference fibers serial number D 211294906410 A and =D 211284906410 Reference fibers A (short) Calibrated Length (LrefA) 21576 m Uncertainty (ALrefA) £05 m Reference fibers B (long) Calibrated Length (LrefB) 20085,7 m Uncertainty (ALrefB) £06 m Setup mH mia ae OTDR Test Jumper 1 Length 0 m OTDR Group Index Setting 1.460000 m OTDR Distance Range 50 OTDR Averaging Time 180 km OTDR Pulse Width 100 sec OTDR Pulse Width 100 ns page 2 of 20 ‘The reported uncertainty is based on a standard uncertainty multiplied by a coverage factor k=2, providing a level of confidence of approximately 95 %. Any quoted uncertainty refers only to the measured value and does not carry any implication regarding the ong term stablityof the instrument. Mt CERTIFICATE OF CALIBRATION [are coecked by: a, Ceniate number : CCLI1710881/07 Measurements Measure the location of the relective end of reference B Test 1 22243 m (L1AB) Test 2 22243 m (L2AB) Test 3 22243 m (L3AB) Test 4 22243 m (L4AB) Test 5 22243 m (L5AB) Test 6 22243 m (L6AB) Average location (LavgAB) avons - 25:18 = 22243, m Measure the location of the reflective end of reference A Test 1 2157 m(L1A) Test 2 2157 m(L2A) Test 3 2187 m(L3A) Test 4 2187 m(L4A) Test § 2187 m(L5A) Test 6 2187 m (LGA) page 3 of 20 ‘The reported uncertainty is based on a standard uncertainty multiplied by a coverage factor k=2, providing a level of confidence of approximately 95 %. Any quoted u jong term stability of the instrument. tainty refers only to the measured value and does Not carry any implication regarding the CERTIFICATE OF CALIBRATION rote OE Checked by : Ky Certificate number - CCL/17/0951/DY ‘Average location (LavgA) LavgA alua = 2157 m Expected locations LexpA = LrefA + Ltit + LdispA 21576 m+ Om+ Om = 21576 m LexpB = LrefB + Lt2 + LaispB 200857 m+ Om+Om 200857 m Locations Errors DerrA = LavgA - LexpA 2187 m - 2157.6 m 06 m DerrB = (LavgB - LavgA) - LexpB 22243 m - 2187m )- 200867 m = 03m age 4 of 20 The reported uncertainty is based on a standard uncertainty multiplied by a coverage fact aporoximately 95 %, Any quoted uncertainty refers only to the measured value ane doe longterm stabiity providing a level of confidence of arry any implication regarding the instrument CERTIFICATE OF CALIBRATION repr OE Indonesia Checked by: A Certificate number - CCLI/17/0951/DY Uncertainties ‘Measurement uncertainty (Ameas) Maximum deviation from average (ALA): LavgA - LiA = 0 om Greatest value between res and (ALA) 1 m(Ameasay Maximum deviation from average (ALB): LavgB-LiB = 0 — m Greatest value between res and (ALB) 1 m(AmeasB) Total uncertainty For reference A (DmaxA) DmaxA = AmeasA + AotdrA + ALdispA + ALrefA = 1 +4 1 + 0 + 08 25 m For reference B (DmaxB) DmaxB = AmeasA + AmeasB + AotdrB + ALdispB + ALrefB 1+ 1 4+ 4 + 0 + 06 36m Acceptance Distance offset Location error A (DerrA) total uncertainty reference A (DmaxA) -06m 25m Distance scaling Location error B (Derr8) total uncertainty reference B (DmaxB) 3m 36m Calibration Pass [1 Fal CO page 5 of 20 The reported uncertainty is based on a standard uncertainty multiplied by a coverage factor K=2, providing a level of confidence of approximately 95 %. Any quoted uncertainty refers oniy to the measured value and does not carry any implication regarding the jong term stability of the instrument Telkom & Indonesia CERTIFICATE OF CALIBRATION Checked by : Certificate number : CCL//17/0951/DY Range Verification OTDR Center Wavelength (Aotdr) 1850 nm OTDR Resolution (res) 1 m Reference fibers serial number 0211294906410 and 0211294906410 Reference fibers A (short) Calibrated Length (Lrefa) 2158.6 m Uncertainty (ALrefA) £05 m Reference fibers B (long) Calibrated Length (LrefB) 20094.4 m Uncertainty (ALref®) £06 m Setup mi ta es OTDR E Test Jumper 1 Length 0 m Test Jumper 2 Length 0 m OTDR Group Index Setting 4.46000 OTDR Distance Range 50 km OTDR Averaging Time 180 sec OTDR Pulse Width 100 ns age 6 of 20 " reported uncertainty is based on a standard uncertainty multiplied by a coverage fector k=2, providing a level of confide Any quoted uncertainty refers only to the measured value and does not carry any Implication reo instrument imately longterm stability of CERTIFICATE OF CALIBRATION Toe OE Checked by: | Certifeate number : CCL//17/0951/DY Measurements Measure the location of the relective end of reference B Test 1 22248 m (L1AB) Test 2 (22248 'm (L2AB) Test 3 22248 m (L3AB) Test 4 (22248 m (L4AB) Test 5 (22248 m (LSAB) Test 22248 m (L6AB) ‘Average location (LavgAB) Levens =29° Ling = 22248 om Measure the location of the reflective end of reference A Test 1 2156 m (L1A) Test 2 2156 m (L2A) Test 3 2156 m(L3A) Test 4 2156 m (L4A) Test 5 2186 m (LSA) Test 6 2156 m (L6A) osae 7 ot20 ‘ong term stability of the instrument. CERTIFICATE OF CALIBRATION ror OE Checked ty: A Certificate number : CCLi/17/0951/DY ‘Average location (LavgA) lLavgA = Expected locations LexpA = LrefA + Ltj1 + LdispA. 21586 m+ 0 m+ 0 m 21586 om Locations Errors avgA - LexpA m (22248 m - 2156 m)- 200944 m =-24 m page 8 of 20 The reported uncertainty is based on a standard uncertainty multiplied by a coverage factor k=2, providing a level of approximately 95 %, Any quoted uncertainty refers only to the measured value and does not carry any implication fe Tong term stably of tne Instrum fidence ot ing the CERTIFICATE OF CALIBRATION Telkom CS Checked by: ra Certificate number : CCL/17/0951/DY Uncertainties Measurement uncertainty (Ameas) ‘Maximum deviation from average (ALA): LavgA-LiA = 0 =m Greatest value between res and (ALA) 1 m/(AmeasA) ‘Maximum deviation from average (ALB): LavgB-LiB = 0 m Greatest value between res and (ALB) 1m (AmeasB) Chromatic dispersion uncertainty (only for 1550nm window) ALdispA=LdispA x 0.2 = O: ox 02 om ALdispB=LdispB x 02 0 x 02 om Total uncertainty For reference A (DmaxA) DmaxA = AmeasA + AotdrA + ALdispA + ALrefA, 1 Peeed eee oO ei eO.5: = 25 m For reference B (DmaxB) DmaxB = AmeasA + AmeasB + AotdrB + ALdispB + ALrefB& = 1 + 1 + 4 + 0 + 06 = 36 m page 9 of 20, The reported uncertainty s based on a standard uncertainty multiplied by @ coverage factor approximately 95. Any quoted uncertainty refers only to the measured value and does not long term stability of the instrurment. providing a level of confidence of ry any implication regarding the CERTIFICATE OF CALIBRATION Teer SE Checked by: A Certificate number : CCLI/17/0951/DY Acceptance Distance offset Location error A < total uncertainty reference A, Derr A < — DmaxA -26m < 25m Distance scaling Location error B < total uncertainty reference B Der B S DmaxB 24m s 36m Calibration Pass 00) Fal page 10 of 20 The reported uncertainty is based on a standard uncertainty multiplied by a coverage factor k=2, providing a le. ;broximately 96 %. Any quoted uncertainty refers only to the measured value ana does not long term stabiity ofthe instrument. Telkom oe Indonesia CERTIFICATE OF CALIBRATION Certificate number : CCL/17/0951/DY Attenuation Verification OTDR Center Wavelength (Aotdr) : 1300 ; nm C Wof NPL Calibration (Anpl) = 1314 nm Reference fibers serial number: D 083075906405 and D 101698406402 Bidirectional U of ref.Attenuation : 0.006 Bim Absolute Attenuation Setup From end A nt ttm) retD(2km) NR Yama a ee os BA 8 From end B a rf C2im ret c(4 en) (Pm ee a a3 a page 11 of 20 The reported uncertainty is based on a standard uncertainty multiplied by a coverage factor k=2, providing a level of confidence o ion regarding the approximately 95 &. Any quoted uncertainty refers only to the measured valug and does not carry any Impl long term stability of the instrument, CERTIFICATE OF CALIBRATION rotor OE Checked by Certificate number : CCLI/17/0951/DY Measurements Section] “Attenuation from end A | Attenuation from end B | Average atlenuation (en) measurement | O7 to 17 O31 O31 0.331 SB, 47027 0.334 0.332 0.333 © [2t037 0.332 0.335 0.334 p70 2.0 anass4aeae 0302 a oss 2.01030 0.334 0.335 0.335 3.01040 0.335 0.332 0.334 4.01050 0.335) 0.331 0.333 5.01060 0.335 0.333 0.334 B. Cso7o 0.382 0.355 0.334 © [7Fowso 0.331 0.337 0.334 8.01090 0.334 0.332 0.333 9.0 t0 10.0) 0.333, 0.335; 0.334 10.010 11.0] 0.335 0.325) 0.332, 14.010 120 0.334 0.331 0.333 Expected Attenuation Anp| 1311 am Attenuations correction Aotdr 1310 nm AA = Q.npl- Rotdr) x ( 0.0008 =( 1311 nm- 1310 nm) x0.0008 _%8_) im Ad = 0,0008 page 12 of 20 The reported uncertainty js based on a standard uncertainty multiplied by a coverage factor k=2, providing a level of confidence of approximately 95 %. Any quoted uncertainty refers only to the measured value and Goes not carry any implication seguraina toe longterm stablty ofthe instrument, Telkom 0.4 Indonesia CERTIFICATE OF CALIBRATION Cocked by: (, Centiicate number : CCLI/17/0951/0¥ Expected Attenuation Section ] NPL average [Attenuation Correction] | Expected attenuation (km) _| Attenuation (dB/km)| +] A (Bim) _ |= B/km O70 17 0.333) (0.0008 = 0.3938 B [47027 0.333 0.0008 = 0.3338 27, = oO to37, 0.333 0.0008 0.3338 r "Ltow20 | ose 00008 |=] 03008 2.01030 0.392, 0.0008 (0.3328 3.01040 0.332 0.0008 0.3828 4.01050 0.332 (0.0008 0.3828 s 5.01060 0.333 0.0008 0.3338, 6.0107.0 0.333 0.0008 0.3338 © [Forse 0.332, 10.0008 0.3328 801090 0.333 (0.0008 0.3338 8.010 10.0 0.333 0.0008 = 0.3338 10.0t011.0 0.332 (0.0008 : 0.3328 11.0 to 12.0) 0.332 (0.0008, = 0.3328 age 13 of 20 The reported uncertainty is based on a standard uncertainty multiplied by a coverage factor k=2, providing a level of confidence of approximately 95 %. Any quoted uncertainty refers only to the measured value and does not carry any implication reseraine tre long term stablty of tne instrument CERTIFICATE OF CALIBRATION rote BE Checked by: Certificate number : CCLI/17/0951/DY Attenuation Error Expected Attenuation |] Allenuation Deviation O70 17 0.0026 171027 5 0.0008 271037 0.334 : 0.3338 = 0.0003 1 70% 20 O38 3 O3306 ‘10002 20t030 0.335 = 0.3328 0.0017 30t040 0.341 : 0.3328 0.0082 401050 0.333 a 0.2328 0.0002 B, [oso 0.334 : 0.3338 0.0002 601070 0.334 zl 0.3338 0.0003 SD Powso 0.334 z 0.3328 0.0012 8.01090 0.333 A 0.3338 0.0008 3.010 10.0 0.334 a 0.3338 0,002 70.010 11.0] 0.332 E 0.3328 ~0,0008 11.010 12.0} 0.333 = 0.3378 5 0.0003 Uncertainty Otdr Uncertainty (AAotdr) Otdr Specified Linearity (lin.otcr) 005 Bras Typical Attenuation of Reference Fiber 0.333 dBikm BAB x 0.333 dB/Km dBm page 14 of 20 he reported uncertainty is based on a standard uncertainty multiplied by a coverage factor approximately 95 %. Any quoted uncertainty refers only to the measured value aro o longterm stability of he instrument 2, providing a level of confidence of Ss not carry any implieation regarding the CERTIFICATE OF CALIBRATION Teor OE Checked by: /, Certificate number : CCL//17/0851/DY Reference Uncertainty (AAref) AAref= 0.006 dB/km Spectral Attenuation Uncertainty (Aaa) AAR = AAXO2 0.0008 dBm x0.2 0.00016 dB/Km Total Uncertainty (Omax) Dmax = AAotdr + Aref + AA) 0.01665 dB/km + 0.006 dB/km + 0.00016 dB/km = 0.02281 aB/Km Acceptance All Attenuation Deviation < Dmax Absolute Attenuation Calibration: Pass [A Fail page 15 of 20 The reported uncertainty is based on a standard uncertainty multiplied by a coverage factor k=2, providing a level of confidence of Pproximately 96 %. Any quoted uncertainty refers oniy to the measured value and does not carry any iplicstion vee cans Hae long term stability ofthe instrument CERTIFICATE OF CALIBRATION rotor OE Checked by: Certificate number : CCLI/17/0951/0Y Attenuation Verification OTDR Center Wavelength (;otdr) 1550 am C Wof NPL Calibration (2npl) 1540 Am Reference fibers serial number —_: D 083075906405 and —-D 101698408402 Bidirectional U of ref Attenuation : 0,006 dBm B. Absolute Attenuation Setup From end A m wfc km) rD (2 km) OTR a i BA . From end B 7 D112 kw) retc(4 hm) ‘OTDR AB A page 16 of 20 ‘The reported uncertainty is based on @ standard uncertainty multiplied by a coverage factor k=2, providing a level of confidence of approximately 95 %, Any quoted uncertainty refers only to the measured value and does rot carry any implication regarding the iong term stablity of the instrument Telkom & Indonesia CERTIFICATE OF CALIBRATION Checked by: 1, Certincate number: CCLI17/0951/0¥ Measurements Section [Attenuation from end A] Attenuation from end B | Average atienuation ian measurement O7 10 T7 O183 0190 0182 B, [az27 0.182, 0.191 0.187 oO [27037 0.201 0.188 0.195 ToIwz0 0.165, 0188 O1e1 2.01030 0.188 0.190 0.189) 3.01040 0.187 0.190 0.189) 401050 0.191 0.190. 0191 @B [Sowso 0.188 0.190 0.189) Sn [6007.0 0.190, 0.189 0.190 SO Poweso 0.188 0.191 0.190 8.01090 0.180 0.188 0.189 8.0 to 10.0 0.192 0.190) 0.191 10.010 11.0 0.191 0.189 0.190 11.0 to 12.0) 0.192 0.189 ‘0.191 Expected Attenuation anpl = 1840 nm ‘Attenuations correction olde 1850 nm A A. = (A mpl Aotdr) x ( 0.0002 |_¢8_| ) = (1540 nm - 1850 rm) x (0.0002 [= 1) Aa = 0.002 [82 page 17 of 20 tor k=2, evel of confidence of The reported uncertainty is based on a standard uncertainty multiplied by a coverage factor k=2, providing a level ofc approximately 95 %. Any quoted uncertainty refers only to the measured value and does nct carry any Implication regarding the long termstabilty of the instrument CERTIFICATE OF CALIBRATION rotor OE Checked by : Ly Certncate number: COLIN7/095V/0¥ Expected Attenuation Section | NPLaverage | [Allenuation Correction] ] Expected attenuation (km)__| Attenuation (aB/km)| +] A 2. (Bsr Bim O7 to tr 0.191 + 0.002 0.189 ss 171027 0.191 + -0.002 = 0.189) © [27637 0.191 + 0.002 0.189 —. nd TOt020 Oa + “0.002 0165 2.01030 0.191 + “0.002 0.489 3.01040 0.191 + 0.002 0.189 401050 0.191 + ~0.002 0.189 B, [ewso 0.191 + 0.002 0.189 6.0107.0 0.191 + 0.002 0189 © [Fowso 0.191 + 0.002 0.189 801090 0.192 + 0.002 0.190 3.010 10.0 0.192 + 0.002 0.190 10.0 to 14.0} 0.192 + 0.002 0.190 11.0 t0 12.0} 0.192 + 0.002 0.190 page 18 of 20 ‘The reported uncerteinty is based on a standard uncertainty multiplied by a coverage factor k=2, providing a level of confidence of approximately 95 %. Any quoted uncertainty refers only to the measured value and does not carry any Implication regarding te iong term stability ofthe instrument Telkom & Indonesia CERTIFICATE OF CALIBRATION Checked by: Certificate number : CCLI/17/0951/DY Attenuation Error ‘Section | Average attenuation Expecied Attenuation | | Altenuation Deviation (kan measurment (dB/km) (dB/krn (dB/Km O7 to 17 0.192 0.188 0.003 B_ (47027 0.187 = 0.185) = 0.003 oS [27037 0.195 = 0.168 = 0.006, 701020 ROie teams) 0765) 0.002 2.01030 0.189) z 0189) 0.000 3.01040 0.189 : 0.189 0.001 401050 0.191 = 0189) 0.002, B, ewse 0.189 = 0.189) 0.000) 6.0107.0 0.190 = 0.188 = 0.001 © [Fos 0.190 = 0.189 = (0.001 8.01080 0.168 : 0.180 = -0.001 9.0 to 10.0) 0.191 -] 0.190) = 0.001 40.0 1011.0] 0.190 : 0.190 = 0.000 11.010 12.0 ‘0191 z 0.190 = 0.007 Uncertainty Otdr Uncertainty (AAotdr) Old Specified Linearty (lin otdr) 0.05 Bid Typical Attenuation of Reference Fiber 0.191 dBm AAotdr = (lin,otdr) x (Aref) = 005 BIdB x0.191 — dB/km = 0.00955 Bim age 19 of 20 The reported uncertainty is based on a standard uncertainty multiplied by a coverage factor k=2, providing a level of confid ‘approximately 95 %. Any quoted uncertainty refers only to the measured value and does not carry sny implication regaral jong torm stability ofthe instrument. Telkom & Indonesia CERTIFICATE OF CALIBRATION Checked by : Certificate number : CCL//17/0951/DY Reference Uncertainty (Aref) Aref =0,008 dB/km Spectral Attenuation Uncertainty (AAA) AAA = ALX0.2 0.002 dBikm x0.2 0.0004 Bim Total Uncertainty (Dmax) AAotdr + Aref + AL 0.00955 dB/km + 0.006 dB/km + 0.0004 dB/km = 0.01595 — dBikm Dmax Acceptance All Attenuation Deviation < Dmax ‘Absolute Attenuation Calibration Pass GZ] Fal age 20 of 20 sopra nareeeesagty a based on a standard uncertainty muliphedby a coverage factor k-2, providing aleve of contidence of aBproximately 95 %. Any quoted uncertainty refers only to the measured value and does nat carry any Impleation regeraing the long term stability ofthe instrument,

You might also like