You are on page 1of 1

Table Of HSI PC Piles Standard Dimension

[ metric system ]
Outer Wall PC WIRE Nominal
Length Moment Bending Moment Allowable axial load
Diam. Thickness Area of
Inertia of
Class Dia (Φ) No. Area concrete Weight
D t L Concrete Cracking Ultimate JIS A-5335 ACI-544
[ mm ] [ mm ] [m] [ mm ] [ pcs ] [ cm2 ] [ cm2 ] [ cm4 ] [ t-m ] [ t-m ] [t] [t] [ kg/m' ]
A 7 6 2.31 2.50 3.75 50 68
300 60 6 - 13 B 7 12 4.62 452 34,608 3.50 6.30 45 63 118
C 7 16 6.16 4.00 8.00 40 60
A 7 8 3.08 3.50 5.25 60 88
350 65 6 - 15 B 7 14 5.39 582 62,163 5.00 9.00 55 84 151
C 7 12 4.62 6.00 12.00 55 79
A 7 10 3.85 5.50 8.25 80 117
400 75 6 - 15 B 7 18 6.93 766 106,489 7.50 13.50 75 110 199
C 9 16 10.18 9.00 18.00 70 106
A 7 12 4.62 7.50 11.25 100 142
450 80 6 - 15 B 7 24 9.24 930 166,570 11.00 19.80 90 132 242
C 9 20 12.72 12.50 25.00 85 128
A 7 14 5.39 10.50 15.75 125 178
500 90 6 - 15 B 7 30 11.55 1159 255,324 15.00 27.00 115 165 301
C 9 24 15.27 17.00 34.00 105 161
A 7 18 6.93 17.00 25.50 170 242
600 100 6 -12 B 9 26 16.54 1571 510,509 25.00 45.00 155 225 408
C 9 34 21.63 29.00 58.00 145 216

Note : - Method of Test Material : Beton Berongga ( JIS A-1136 )