Professional Documents
Culture Documents
Pile Length and Lateral Load Capacity of Clarification No.8
Pile Length and Lateral Load Capacity of Clarification No.8
Pile Material
Geotech Capacity Allowable Lateral Load
Sr. Name Pile Size(mm) Capacity Depth(m)
(tons) Capacity( tons)
(tons)
1 Storm Water Drain (Type-1)* 200x200 30 12\26 10\48 2.4
2 Strom Water Drain (Type-2)* 200x200 30 12\26 6.4\39 2.4
3 Strom Water Drain (Type-3)* 200x200 30 12\26 6.3\44 2.4
4 Sumpit 200x200 30 26 27 2.4
4 Sewage Pumping Station 200x200 30 17 12 16.0
5 FRP Fuel Tank Foundation 200x200 30 26 41 22.5
6 CCTV Pole and Light Pole 200x200 30 26 44 8.7
7 Leaking Comtainer Bay 200x200 30 26 41 60.3
8 Hydrant and Isolation Chamber 150x150 15 12 5.4 6.1
Meter an Valve Chamber and Hose
9 150x150 15 12 5.4 6.1
station
10 High Mast Foundation 250x250 30 26 58 22.8